[. . . ] Ultra® 2400 Series Dispensing Workstation
User's Guide
Electronic pdf files of EFD® manuals are also available at www. efd-inc. com/manuals. html.
Ultra 2400 Ultra 2405 Ultra 2415
®
A NORDSON COMPANY
Introduction
Welcome to the Ultra 2400 Series, the most complete dispensing system on the market. This User's Guide will help you maximize the usefulness of your new workstation. Please spend a few minutes to become familiar with the controls and features. Review the helpful information we have included, which is based on more than 30 years of industrial dispensing experience. [. . . ] Using air pressure, the barrel loader fills the syringe barrel (with a piston installed) from the bottom up. If the fluid comes packed in a 1/10 gallon (300 ml. ) caulking type cartridge, use the EFD #940BL barrel loader. For fast, volumetric filling, the automated 8000BF system is an accurate, easy and fast system to fill syringe barrels. If you receive frozen epoxies or other fluids in medical type syringes with a manual plunger, request the EFD luer-to-luer fitting #2160 to transfer the material. Please contact an EFD fluid application specialist for additional assistance.
EFD #920BL Barrel Loader (Specify #940BL for prefilled 1/10 gal. caulking tubes) 2/3 Maximum Fill
EFD #8000BF Barrel Filling Station
POSITION BAND ABOVE LINE
55cc
30cc
10cc 5cc 3cc
Filling the cartridge for the barrel loader
Barrel Rack #905BR for 3cc & 5cc barrels #910BR for 10cc, 30cc and 55cc barrels
Start
5
7
6
8
50
9
10
40
30
60
14
1. 0
7
0
Stop
Stop Fill
15
Start Fill
Cylinder Pressure
Fluid Pressure
Barrel Fill Station
10
0
90
#2160 Luer-to-luer fitting
0. 4
4
0. 6
3
4
70
11
5 2
20
Power
3
0. 8 0. 2
80
13
12
6
2
1
10
1
0
15
Initial Test Procedures
Deposit size is controlled by time, pressure and tip size. Use the convenient Dot Standards sheet included in your dispensing system kit.
Setup for Testing
1. Attach an EFD syringe barrel filled with your assembly fluid to the adapter assembly as shown. Run through the following tests to demonstrate the ease at which deposit sizes can be established using the various dispense modes.
Testing in Steady Mode
· · · · · Select STEADY mode. Pull the air pressure regulator knob out until it clicks into the unlocked position. Slowly, turn the pressure knob clockwise until your fluid begins to dispense out of the tip in a controlled flow (not too fast, not too slow). Push the air pressure knob in to lock setting.
Remember - always bring the tip in contact with the work surface at the illustrated angle. Release pedal and remove tip by lifting straight up.
45º
Correct angle for consistent deposits.
16
Initial Test Procedures
Testing in Timed Mode
· · · · · · Follow steps in "Testing in Steady Mode" to purge your dispensing tip with fluid. Press the foot pedal (or finger switch) to activate the dispense cycle. If your dot is too small, increase the dispense time to increase the deposit size. If your dot is too large, decrease the dispense time to decrease your deposit size.
Testing in Teach Mode
· · · · · · · Follow steps in "Testing in Steady Mode" to purge your dispensing tip with fluid. Tapping the foot pedal repeatedly will have a cumulative effect on the dot size and dispense time. Continue to press the foot pedal until you achieve the correct deposit size. If needed, press CLEAR to start over.
If you have any questions at this point, please call us now.
In the USA, call 800-556-3484 between 8:30 a. m. In Europe, call +44 (0) 1582 666334 In Asia, call +86 (21) 5854 2345 In all other areas, call your authorized EFD distributor or +1-401-434-1680.
17
Memory
The Ultra 2400 dispensing workstation allows you to store the dispense time, pressure and vacuum settings for up to 16 different job programs. Programs are saved even with power removed and will remain in storage unless changed or erased intentionally. Note: Dispense time is automatically adjusted when you select an individual job program. [. . . ] Specify EFD part #2429.
Stiff arm barrel holder
This stiff arm mounts to the work panels and securely holds the syringe barrel in a fixed position. Specify EFD part #2434.
Barrel hand grip with finger switch and light
Hand grip with innovative finger switch that is activated by a built-in touch sensor. Incorporates a high-beam penlight to illuminate the dispensing target area. Specify EFD part #2440FS.
Workstation lamp
Helpful work lamp is mounted on a flexible arm, can be adjusted to multiple positions and provides targeted lighting to help operators work with greater accuracy and comfort. [. . . ]