If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EAGLE ACCESS CONTROL SYSTEMS EAGLE POWER I. We hope that this EAGLE ACCESS CONTROL SYSTEMS EAGLE POWER I user guide will be useful to you.
Manual abstract: user guide EAGLE ACCESS CONTROL SYSTEMS EAGLE POWER I
Detailed instructions for use are in the User's Guide.
[. . . ] INSTALLATION & OWNER'S MANUAL
THE EAGLE POWER I BATTERY BACK UP
PHONE (818) 764-6690 / TOLL FREE (800) 708-8848
PRE INSTALLATION INSTRUCTIONS
!
CAUTION!
!
CAUTION!
BEFORE PROCEEDING WITH INSTALLATION READ THIS MANUAL THOROUGHLY AND CAREFULLY FOLLOW ALL THE OPERATION INSTRUCTIONS.
USE ONE POWER I BATTERY BACK-UP SYSTEM PER EACH GATE OPERATOR. [. . . ] Connect the incoming AC line to the AC In as follows: L - AC Line In (Live): Black N - AC neutral (Common): White G - AC Ground (Earth): Green Connect the outgoing AC line to the AC Out as follows: L - AC Line Out: Black N - AC neutral: White G - AC Ground: Green
Refer to the installation manual provided with operator for the proper connections to the operator
APPLYING THE POWER AND CONNECTING THE SYSTEM RELAY
With the power to the operator and breaker box turned off and all of the AC line connections are complete, install the provided relay. When testing is completed, turn on the breaker and the green inverter light will go off, then charger green or yellow light will go on. FOR HOLD OPEN APPLICATION Connect the two orange terminals to the "exit open" on the operator. Using this connection will immediatly open the gate upon power failure. Gate operator will resume normal operation when power is resumed.
Eagle recommends surge protection be installed on the incoming 110 AC Line to the battery back-up unit.
IMPORTANT!
(4)
INSIDE OF THE EAGLE POWER I
INVERTER
REAR BATTERY
SUB-PANEL
RELAY SOCKET TIMER
RED WIRES (+)
+
L
HOLD OPEN COM N/O _+
AC OUT NG L
AC IN NG
+
FRONT BATTERY
BLACK WIRES (-)
(5)
MOUNTING THE EAGLE POWER PS INSTALLATION OF THE E-I I
17 1/2"
MOUNTING BRACKETS
12 3/8"
REAR VIEW OF CONTROL BOX
Mounting Holes 3/8" Diameter
7" (OC)
MOUNTING BRACKETS
3" 15" 16 1/2"
(OC) (Drawing N. T. S. )
(6)
SPECIFICATIONS & WARRANTY
TECHNICAL SPECIFICATIONS
INPUT VOLTAGE: BATTERY: RECHARGE TIME: OUTPUT VOLTAGE: OUTPUT FREQUENCY: OUTPUT CURRANT: SURGE CURRANT: AC OUTPUT POWER: SURGE POWER: RELAY OUTPUTS:
105 - 125 VAC 12VDC / 70AH 8 HOURS 115 VAC 60 Hz 5 AMPS 9 AMPS 800 WATTS 1600 WATTS 2 AMPS
!
CAUTION!
DO NOT EXCEED THE OUTPUT CAPACITY OF THE POWER I. CONNECTING A MOTOR LOAD LARGER THAN RECOMMENDED WILL DAMAGE THE POWER I AND VOID THE WARRANTY.
MANUFACTURER'S LIMITED WARRANTY
Eagle Access Control Systems, Inc. warrants its Power I to be free from defect in material and workmanship for a period of one (1) year from the date of purchase for single family home or multi-family and commercial use. To obtain service under this warranty the buyer must obtain authorization instructions for the return of any goods from Eagle before returning the goods. [. . . ] No person is authorized to assume for Eagle any other liability in connection with the sale of this product.