User manual DYNASTY SPAS VS500501 GS500501 CONTROL REFERENCE CARD

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DYNASTY SPAS VS500501 GS500501 CONTROL REFERENCE CARD. We hope that this DYNASTY SPAS VS500501 GS500501 CONTROL REFERENCE CARD user guide will be useful to you.


DYNASTY SPAS VS500501 GS500501 CONTROL REFERENCE CARD : Download the complete user guide (444 Ko)

Manual abstract: user guide DYNASTY SPAS VS500501 GS500501 CONTROL REFERENCE CARD

Detailed instructions for use are in the User's Guide.

[. . . ] Temp/Set (80°F - 104°F / 26°C - 40°C) The start-up temperature is set at 100F°/37°C. Note that the last measured spa temperature displayed is current only when the circ pump has been running for at least 2 minutes. To display the set temperature, press the "Temp" or "Set" pad once. [. . . ] " " will display solid when temperature is not current, and will alternate with temperature when temperature is current. Preset Filter Cycles The first filter cycle begins 6 minutes after the spa is energized. Filter duration is programmable for 2, 4, 6, 8 hours or for continuous filtration (indicated by " "). To program, press "Temp" or "Set, " then "Jets. " Press "Temp" or "Set" to adjust. At the beginning of each filter cycle the blower purges for 30 seconds; the pump purges for 5 minutes. The only effect filter duration has is: 1) During the filter, the circ pump never turns off, and 2) In Economy and Sleep Modes, heating only occurs during the filter cycle. Jets Touch the "Jets" button once to turn pump 1 on or off, and to shift between low and high speeds (if equipped). If left running, the low speed of the pump will automatically turn off after 4 hours, and the high speed will automatically turn off after 15 minutes. Freeze Protection If the temperature sensors detect a drop to below 44°F/6. 7°C within the heater, the pump and blower will automatically activate to provide freeze protection. The equipment stays on until 4 minutes after the sensors detect that the spa temperature has risen to 45°F/7. 2°C or higher. In colder climates, an optional additional freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard sensors. Aux freeze sensor protection acts similarly except with the temperature thresholds determined by the switch and without a 4-minute delay in turnoff. See your dealer for details. Blower (optional on VS501 or GS501) This button is used to turn the blower on and off. If left on, the blower automatically turns off after 15 minutes. Jets 2 (optional on VS501 or GS501) If your system has a pump 2 installed instead of a blower, it behaves exactly like a blower would. Light Press the "Light" button to turn the light on and off. If left on, the light automatically turns off after 4 hours. (over) Diagnostic Messages Message Meaning No message on display. Action Required The control panel will be disabled until power returns. After the circ pump has been running for 2 minutes, the temperature will be displayed. If spa does not reset, shut off the power to the spa and call your dealer or service organization. If spa does not reset, shut off the power to the spa and call your dealer or service organization. The pump and blower will automatically activate regardless of spa status. (May appear temporarily in an overheat situation and disappear when the heater cools. ) If the problem persists, contact your dealer or service organization. [. . . ] Possible inadequate water, poor flow, or air bubbles in detected in the heater. Spa is shut down for 15 minutes. Inadequate water detected in heater. (Displays on third occurrence of " " message. ) Spa is shut down. Warning! [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DYNASTY SPAS VS500501 GS500501 CONTROL REFERENCE CARD




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DYNASTY SPAS VS500501 GS500501 CONTROL REFERENCE CARD will begin.

 