User manual DYNASTY SPAS PARAMOUNT (ELGL) CONTROL WML700 PANEL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DYNASTY SPAS PARAMOUNT (ELGL) CONTROL WML700 PANEL. We hope that this DYNASTY SPAS PARAMOUNT (ELGL) CONTROL WML700 PANEL user guide will be useful to you.


DYNASTY SPAS PARAMOUNT (ELGL) CONTROL WML700 PANEL : Download the complete user guide (466 Ko)

Manual abstract: user guide DYNASTY SPAS PARAMOUNT (ELGL) CONTROL WML700 PANEL

Detailed instructions for use are in the User's Guide.

[. . . ] The system keeps track of timeouts regardless of other conditions occurring. In multi-button sequences, if buttons are pressed too quickly in sequence, they may not register. Initial Start-up When your spa is first actuated, it will go into Priming mode (after displaying some configuration information). Please see the M-7 Installation Instruction Manual for complete instructions on Power-up and Pump Priming. The Priming mode will last for up to 4 minutes and then the spa will begin to heat the spa and maintain the water temperature in the Standard mode. [. . . ] To set the time, press "Time" then "Mode/Prog. " Use the "Warm" and "Cool" buttons to adjust time. (Time settings on EL2000 and EL1000 systems are not preserved in the event of power loss; time will have to be reprogrammed upon each power up. ) If your spa has an optional pH/Orp sensor (not available on EL2000 or EL1000 systems), pressing "Time" twice will display the current pH level; pressing it three times will display the current Orp. Mode/Prog This button is used to switch between standard, economy, and sleep modes. Press "Mode/Prog" to enter mode programming, press "Cool" to cycle through to desired mode (LCD flashes until confirmed), then press "Mode/Prog" to confirm selection. Note that the last measured spa temperature displayed is current only when the pump has been running for at least 2 minutes. Economy mode heats the spa to the set temperature only during filter cycles. Pressing "Jets 1" while in Economy mode puts the spa in Standard-In-Economy mode, which operates the same as Standard Mode, then reverts to Economy Mode automatically after 1 hour. During this time, a press of the "Mode/Prog" button will revert to Economy Mode immediately. Sleep mode heats the spa to within 20°F (11°C) of the set temperature only during filter cycles. The "SLEEP" icon will display until mode is changed. Circ Pump (optional) If your system is equipped with a circ pump, it may be configured to work in one of three different ways: 1) The circ pump operates continuously (24 hours) with the exception of turning off for 30 minutes at a time when the water temperature reaches 3°F (1. 5°C) above the set temperature (most likely to happen in very hot climates). 2) The circ pump stays on continuously, regardless of water temperature. 3) The circ pump will come on when the system is checking temperature (polling), during filter cycles, during freeze conditions, or when the blower or another pump is on. Standby Mode Pressing "Warm" or "Cool" then "Jets 2" will turn off all spa functions temporarily. Press any button to exit Standby mode. Jets 1 Press the "Jets 1" button once to turn pump 1 on or off, and to shift between low and high speeds (if equipped). If left running, the low speed turns off after 2 hours and the high speed turns off after 15 minutes. * On non-circ systems, the low speed of pump 1 runs when the blower or any other pump is on. It may also activate for at least 2 minutes every 30 minutes to detect the spa temperature (polling) and then to heat to the set temperature if needed, depending upon mode. When the low speed turns on automatically, it cannot be deactivated from the panel; however, the high speed may be started. Preset Filter Cycles On all systems, the pump and the ozone generator** will run during filtration. At the start of each filter cycle, the blower will run on highest speed for 30 seconds to clean out the air channels. The lowest speed of pump 2 and pump 3 will run for 5 minutes. (The following is specific to all systems that are programmed according time) There are two filter cycles per day. To program, set time as instructed above, then press "Mode/Prog" to advance to the next setting (or to exit after the last setting). The default filter cycles are as follows: The first filter cycle is automatically activated at 8:00 AM and operates the pump until 10:00 AM. The second filter cycle is automatically activated at 8:00 PM and operates the pump until 10:00 PM. The filter 2 indicator icon will light when filter 2 is running. Jets 2 (optional on EL5000, EL2000 and EL1000) Press the "Jets 2" button once to turn pump 2 on or off, and to shift between low and high speeds if it is a two-speed pump. If left running, the pump will turn off after 15 minutes. * Jets 3 (optional on all EL8000 systems or on EL5000 systems without a blower) Press the "Jets 3" button once to turn pump 3 on or off, and to shift between low and high speeds if it is a two-speed pump. [. . . ] (Displays on third occurrence of "dr" message. ) Spa is shut down. When your spa is first actuated, it will go into Priming mode. Temperature unknown. Temperature not current in Economy or Sleep mode. Standby Mode has been activated by pressing a button combination on the user panel. Sanitizer is high. Periodic Reminder Messages Message Frequency Every 7 days Every 7 days (Press the "Mode" button to reset a displayed reminder) Action Required Test and adjust pH chemical levels per manufacturer's instructions. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DYNASTY SPAS PARAMOUNT (ELGL) CONTROL WML700 PANEL




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DYNASTY SPAS PARAMOUNT (ELGL) CONTROL WML700 PANEL will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.