User manual DYNAMIC ENGINEERING PMC BISERIAL-II PS2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DYNAMIC ENGINEERING PMC BISERIAL-II PS2. We hope that this DYNAMIC ENGINEERING PMC BISERIAL-II PS2 user guide will be useful to you.


DYNAMIC ENGINEERING PMC BISERIAL-II PS2 : Download the complete user guide (324 Ko)

Manual abstract: user guide DYNAMIC ENGINEERING PMC BISERIAL-II PS2

Detailed instructions for use are in the User's Guide.

[. . . ] 95005 831-336-8891 Fax 831-336-3840 sales@dyneng. com www. dyneng. com Est. 1988 User Manual PMC BiSerial-II PS2 4 channel Bi-directional Serial Data Interface PMC Module Revision A Corresponding Hardware: Revision A 10-2002-1201 PMC BiSerial-II PS2 Bi-Directional Serial Data Interface PMC Module This document contains information of proprietary interest to Dynamic Engineering. It has been supplied in confidence and the recipient, by accepting this material, agrees that the subject matter will not be copied or reproduced, in whole or in part, nor its contents revealed in any manner or to any person except to meet the purpose for which it was delivered. Dynamic Engineering has made every effort to ensure that this manual is accurate and complete. [. . . ] When the direction is set to output the bit definitions from this register are driven onto the corresponding parallel port lines. The IO side is read-back from the Status1 port also the lowest 8 bits. It is possible that the output data does not match the IO data in the case of the Direction bits being set to input. Hardware and Software Design · Manufacturing Services Page 19 BIS2_STAT0 [$14] BiSerial II Status Port 0 read status, write clear STATUS 0 DATA BIT 31-25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 DESCRIPTION Spare interrupt status f7_intr_lat f6_intr_lat f5_intr_lat f4_intr_lat f3_intr_lat f2_intr_lat f1_intr_lat f0_intr_lat r7_intr_lat r6_intr_lat r5_intr_lat r4_intr_lat r3_intr_lat r2_intr_lat r1_intr_lat r0_intr_lat rx3_intr_lat rx2_intr_lat rx1_intr_lat rx0_intr_lat tx3_intr_lat tx2_intr_lat tx1_intr_lat tx0_intr_lat FIGURE 10 PMC BISERIAL-II STATUS REG 0 BIT MAP When Interrupt Status is read as a one, it indicates that one or more latched interrupt conditions are true. In order for an actual system interrupt to occur, the interrupt enable for that condition and the Master Interrupt Enable must both be asserted. When this bit is zero, no interrupt conditions are pending. Hardware and Software Design · Manufacturing Services Page 20 The interrupt conditions are latched and held in special interrupt status latches. The latched bits remain set until the corresponding bit is written back to the port. When an interrupt occurs or if polling is used this port can be used to determine which channel requires attention. The active channel should be taken care of and then the bit set to clear the request. The combination of port access and bit position set is used to clear the bit. To use as an interrupt the Tx_Int_En0-3 [Bis2_TX] must also be set as well as the master interrupt enable. To use as an interrupt the Rx_Int_En0-3 [Bis2_RX] must also be set as well as the master interrupt enable. R0-7_intr_lat is set when the parallel port bit has received a rising transition 0->1. To use as an interrupt the par_int_en_r0-7 [Bis2_COSEN] must also be set as well as the master interrupt enable. F0-7_intr_lat is set when the parallel port bit has received a falling transition 1->0. To use as an interrupt the par_int_en_f0-7 [Bis2_COSEN] must also be set as well as the master interrupt enable. Hardware and Software Design · Manufacturing Services Page 21 BIS2_STAT1 [$18] BiSerial II Status Port 1 read only FIFO Status, Parallel Data In & Switch Register DATA BIT 31-24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7-0 DESCRIPTION sw7-0 rx_fifo_full3 rx_fifo_full2 rx_fifo_full1 rx_fifo_full0 rx_fifo_mt3 rx_fifo_mt2 rx_fifo_mt1 rx_fifo_mt0 tx_fifo_full3 tx_fifo_full2 tx_fifo_full1 tx_fifo_full0 tx_fifo_mt3 tx_fifo_mt2 tx_fifo_mt1 tx_fifo_mt0 dat_in7-0 FIGURE 11 PMC BISERIAL-II STATUS 1 BIT MAP The Switch Read Port has the user bits. The switches allow custom configurations to be defined by the user and for the software to identify a particular board by its switch settings and to configure it accordingly. The Dip-switch is marked on the silk-screen with the positions of the digits and the '1' and '0' definitions. The 1 example shown would produce 0x12 when read [and shifted 0 down] from the BIS2_STAT1 port. 7 0 Tx_fifo_mt3-0 is '1' when the Transmit FIFO is empty for that channel. When data Hardware and Software Design · Manufacturing Services Page 22 is stored in the FIFO the status will be '0'. Tx_fifo_full3-0 is '1' when the Transmit FIFO is full for that channel. Rx_fifo_mt3-0 is '1' when the Receive FIFO is empty for that channel. [. . . ] The coefficient means that if 2. 17 Watts are applied uniformly on the component side, then the temperature difference between the component side and solder side is one degree Celsius. Thermal Considerations The BiSerial II design consists of CMOS circuits. It is possible to create a higher power dissipation with the externally connected logic. If more than one Watt is required to be dissipated due to external loading then forced air cooling is recommended. With the one degree differential temperature to the solder side of the board external cooling is easily accomplished. Hardware and Software Design · Manufacturing Services Page 35 Warranty and Repair Please refer to the warranty page on our website for the current warranty offered and options. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DYNAMIC ENGINEERING PMC BISERIAL-II PS2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DYNAMIC ENGINEERING PMC BISERIAL-II PS2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.