User manual DOD R410

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DOD R410. We hope that this DOD R410 user guide will be useful to you.


DOD R410 : Download the complete user guide (500 Ko)

Manual abstract: user guide DOD R410

Detailed instructions for use are in the User's Guide.

[. . . ] · The core which is colored blue must be connected to the terminal marked N or colored black. · The core which is colored brown must be connected to the terminal marked L or colored red. R410 Manual 6/8/99 10:41 AM Page 2 2 These units comply with the European "EMC Directive" for emissions and susceptability. The green/yellow wire is connected directly to the unit's chassis. If you need to change the plug, and if you are qualified to do so, refer to the table below. CONDUCTOR L N LIVE NEUTRAL WIRE COLOR Normal BROWN BLUE Alt BLACK WHITE GREEN E EARTH GND GREEN/YEL WARNING: If the ground is defeated, certain fault conditions in the unit or in the system to which it is connected can result in full line voltage between chassis and earth ground. [. . . ] The peak LED indicates that. the signal out of the EQ section is 3dB below clipping. R410 Manual 6/8/99 10:41 AM Page 4 4 5. Notch Filters - These two filters are very narrow bandwidth notch filters that can provide 24dB of attenuation at the selected frequency. The x10 function allows you to change the range of each notch (see the graph below). These filters are "Disabled" by setting the depth control to the top (0dB cut). These filters are used primarily for eliminating feedback or hum from the P. A. or monitor systems. Notch 1 40Hz 400Hz 4KHz 20Hz 200Hz 2KHz 20KHz Notch 2 standard range x10 ranges 6. Limiter - The limiter function features Automatic Variable Ratio LimitingTM. AVR Limiting behaves as a mild compressor with a soft knee at low threshold settings, and a hard knee limiter at higher threshold settings. This allows the limiter to function as a mild compressor or as a limiter for speaker protection. The gain reduction meter displays the amount of gain reduction due to limiting. Low Cut - A selectable low cut (high pass) filter that may be switched in or out and has selectable rolloff frequency of 40 or 80Hz. R410 Manual 6/8/99 10:41 AM Page 5 Rear Panel 1 BAL OUTPUT BAL / UNBAL OUTPUT 2 3 BAL THRU OUTPUT 4 BAL / UNBAL THRU OUTPUT 5 BAL INPUT 6 BAL / UNBAL INPUT 117 V 50 / 60 Hz 18 WATTS MANUFACTURED IN THE USA BY CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE BACK. WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. WARNING: SHOCK HAZARD-DO NOT OPEN AVIS: RISQUE DE CHOC ÉLECTRIQUE-NE PAS OUVRIR SALT LAKE CITY, UTAH 5 1. Balanced Output -Accepts a female XLR plug (see section on installation for wiring). Balanced/Unbalanced Output - Accepts a 1/4" tip-ringsleeve balanced or 1/4" unbalanced tip-sleeve plug (see section on installation for wiring connections). Output impedance is 20k for the unbalanced connection and 40k for balanced. Balanced Thru Output - Accepts a female XLR plug (see section on installation for wiring connections). This output is hardwired to the input allowing the signal to be split off to another destination. Balanced/Unbalanced Thru Output - Accepts a 1/4" tipring-sleeve balanced phone plug or a 1/4" unbalanced tip-sleeve plug (see section on installation for wiring connections). Balanced Input - Accepts a male XLR plug (see section on installation for wiring connections). Balanced/Unbalanced Input - Accepts a 1/4" tip-ring-sleeve balanced phone plug or a 1/4" unbalanced tip-sleeve plug (see section on installation for wiring connections). Input impedance is 51 for the unbalanced connection and 102 for balanced . R410 Manual 6/8/99 10:41 AM Page 6 6 INSTALLATION Install the 410 in a rack with the provided rack screws. [. . . ] All service and repair must be performed by the factory for the warranty to remain in service. R410 Manual 6/8/99 10:41 AM Page 9 Should a problem arise with the product, please contact your authorized DOD Electronics dealer for return/repair procedures. DOD Warranty The warranty registration card must be mailed within ten days after the purchase date to validate this warranty. 9 DOD warrants this product, when used solely within the U. S. , to be free from defects in material and workmanship under normal use and service. DOD Electronics liability under this warranty is limited to repairing or replacing defective materials that show evidence of defect, provided the product is returned through the original dealer, where all parts and labor will be covered up to a period of one year. The company shall not be responsible for any consequential damage as a result of the products use in any circuit or assembly. Proof of date of purchase is considered to be the burden of the consumer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DOD R410




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DOD R410 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.