User manual DIPLOMAT ADP8322

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DIPLOMAT ADP8322. We hope that this DIPLOMAT ADP8322 user guide will be useful to you.


DIPLOMAT ADP8322 : Download the complete user guide (12172 Ko)

Manual abstract: user guide DIPLOMAT ADP8322

Detailed instructions for use are in the User's Guide.

[. . . ] Syncing Comprehensive - can sync to Word Clock or AES reference, or signal, and sync to video option available. Functions Sample Rate and Format Conversion Multichannel Sync capability Bit for bit multiplex/demultiplex mode PCM to DSD, DSD to PCM DC Removal for DSD Multiple filters on many major sample rate conversions Dither ­ 3 types Noise shaping ­ 10 different options on all major PCM sample rates Output Level control with "Maximise" Balance control Digital Silence out with digital silence in Monitoring Bit Activity, Stereo Level, and CRC, Parity & Invalid flag errors in the input data. Test Generator High quality (160 dB) signal generator with mHz resolution. Pre-loaded setups Remembers last settings Lockouts Manual part no: DOC1241102C2 Contact dCS on + 44 1799 531 999 Page 3 Document No: OS-MA-A0124-110. 2C2 (inside the UK replace + 44 with 0) email to: more@dcsltd. co. uk web site: www. dcsltd. co. uk dCS ADP8322 User Manual dCS Ltd Manual for Software Version 2. 3x January 2001 Contents Product Features About this Manual Product Overview What's in the Box? [. . . ] appears on the right hand side of the Status, Error Monitor, Test Mode, Info, Bit Activity Monitor or Level Meter screen as appropriate and the front panel controls have no effect. To restore normal operation, hold down the Status button and press the Edit label will disappear and normal operation will be button. The resumed. Manual part no: DOC1241102C2 Contact dCS on + 44 1799 531 999 Page 45 Document No: OS-MA-A0124-110. 2C2 (inside the UK replace + 44 with 0) email to: more@dcsltd. co. uk web site: www. dcsltd. co. uk dCS ADP8322 User Manual dCS Ltd Manual for Software Version 2. 3x January 2001 TYPICAL APPLICATIONS Converting a 24/96 recording to CD format From 24bit / 96kS/s source 16 bit / 44. 1kS/s from 3 independent AES outputs AES1 PUSH AES2 PUSH AES CLK PUSH AES1 AES2 AES CLK In SDIF-2 Inputs CH1 CH2 CLK AES / EBU Inputs AES / EBU Outputs Out Remote MAINS FUSE 2A(T) ON OFF SPDIF1 SPDIF2 SPDIF3 SYNC IN CH1 CH2 CLK SDIF-2 Outputs 16 bit / 44. 1kS/s SDIF-2 output 16 bit / 44. 1kS/s from 3 independent SPDIF outputs Figure 3 ­ Double Speed 24/96 to CD format The dCS ADP8322 converts a double speed 96 kS/s 24 bit AES input to a 44. 1 kS/s 16 bit signal available from all of the 3 AES, 2 electrical SPDIF, optical SPDIF or SDIF-2 outputs. The SonicStudioTM uses 24/96 in double speed AES at the time of writing. do this: do this: do this: Connect Sonic Solutions SonicStudioTM workstation AES output to AES 1 input on the dCS ADP8322. Output from either AES A or AES B or any of the SPDIF outputs or, using two data cables and one clock, via the SDIF-2 outputs. Sample Rate Conversion settings: The settings below are preloaded into Store 1 by dCS, although they may be overwritten. Sample Rate Conversion: Audio Input Select: Sync Source: Input Frequency: Output Frequency: Output Mode Filter: Output Wordlength: Noise Shaping: Dither Detect Silence: AES Message Edit: SPDIF Message Edit: On AES 1 Audio Input 96 kS/s 44. 1 kS/s Normal Filter 2 16 2nd Order Noise shaped triangular On Professional Off, Non-Audio Off Mode: Stereophonic Professional Off, Non-Audio Off, Copy Permit On Format: Compact Disc Manual part no: DOC1241102C2 Contact dCS on + 44 1799 531 999 Page 46 SPDIF Outputs SPDIF Inputs Document No: OS-MA-A0124-110. 2C2 (inside the UK replace + 44 with 0) email to: more@dcsltd. co. uk web site: www. dcsltd. co. uk dCS ADP8322 User Manual dCS Ltd Manual for Software Version 2. 3x January 2001 Demultiplexing a 24/96 Dual AES recording (Bit for Bit) From 24bit / 96kS/s Dual AES source Ensure AES1 & AES2 are connected correctly. AES1 = Left data AES2 = Right data AES CLK PUSH 24 bit / 96kS/s from 3 independent AES outputs AES1 PUSH AES2 PUSH AES1 AES2 AES CLK In SDIF-2 Inputs CH1 CH2 CLK AES / EBU Inputs AES / EBU Outputs Out Remote MAINS FUSE 2A(T) ON OFF SPDIF1 SPDIF2 SPDIF3 SYNC IN CH1 CH2 CLK SDIF-2 Outputs 24 bit / 96kS/s SDIF-2 output 24 bit / 96kS/s from 3 independent SPDIF outputs Figure 4 ­ Converting dual AES 24/96 to a single wire double speed one The dCS ADP8322 converts a 96 kS/s 24 bit Dual AES input to a double speed 96 kS/s 24 bit signal available from any or all of the 3 AES, 2 SPDIF or SDIF-2 outputs. When using the Format Conversion menu, the operation is bit for bit on the audio data (messages can be edited). do this: do this: do this: Connect Nagra-D, Genex G-8000, SADIE, Lake DSP, etc dual AES source to inputs AES 1 and AES 2 on the dCS ADP8322. load the setup from Store 2, or use settings below Output from either AES A or AES B or any of the SPDIF outputs or, using two data cables and one clock, via the SDIF-2 outputs. You can overwrite them. Manual part no: DOC1241102C2 Contact dCS on + 44 1799 531 999 Page 52 Document No: OS-MA-A0124-110. 2C2 (inside the UK replace + 44 with 0) email to: more@dcsltd. co. uk web site: www. dcsltd. co. uk dCS ADP8322 User Manual dCS Ltd Manual for Software Version 2. 3x January 2001 Multi-channel Sample Rate Conversion ­ Using a Master Clock TO RECORDER (44. 1kS/s WORDCLOCK) AES 1 more@dcsltd. co. uk AES 2 AES 3 AES 4 Wordclock Outputs 1 2 3 4 5 6 In Mains Fuse (2AT) On Off AES/EBU Outputs 7 8 9 10 11 12 External Sync Loop Out Remote A AES1 PUSH dCS 992 Master Clock AES2 PUSH 96kS/s Ch1 & 2 AES CLK PUSH AES1 AES2 AES CLK In SDIF-2 Inputs CH1 CH2 CLK AES / EBU Inputs AES / EBU Outputs Out Remote MAINS FUSE 2A(T) ON OFF SPDIF1 SPDIF2 SPDIF3 SYNC IN CH1 CH2 CLK SDIF-2 Outputs SPDIF Outputs SPDIF Inputs 96kS/s Ch3 & 4 AES1 PUSH AES2 PUSH AES CLK PUSH AES1 AES2 AES CLK In SDIF-2 Inputs CH1 CH2 CLK AES / EBU Inputs AES / EBU Outputs 44. 1kS/s SOURCE Out Remote MAINS FUSE 2A(T) ON OFF SPDIF1 SPDIF2 SPDIF3 SYNC IN CH1 CH2 CLK SDIF-2 Outputs SPDIF Outputs SPDIF Inputs 96kS/s Ch5 & 6 AES1 PUSH AES2 PUSH AES CLK PUSH AES1 AES2 AES CLK In SDIF-2 Inputs CH1 CH2 CLK AES / EBU Inputs AES / EBU Outputs Out Remote MAINS FUSE 2A(T) ON OFF SPDIF1 SPDIF2 SPDIF3 SYNC IN CH1 CH2 CLK SDIF-2 Outputs SPDIF Outputs SPDIF Inputs 96kS/s Ch7 & 8 AES1 PUSH AES2 PUSH AES CLK PUSH AES1 AES2 AES CLK In SDIF-2 Inputs CH1 CH2 CLK AES / EBU Inputs AES / EBU Outputs Out SPDIF3 CH2 CLK Figure 10 ­ Multi-channel Sample Rate Conversion with Master Clock You can use a dCS 992 Master Clock to sync up the source and be the master. The sync link cabling starts from the master clock (cable "A") and then carries on down units as shown. Use of the master clock allows more units to be used together ­ 24 channels worth or more. Make sure that all the other settings are the same on each unit. 13 13 version 2. 0 or higher software Manual part no: DOC1241102C2 Contact dCS on + 44 1799 531 999 Page 53 Remote Document No: OS-MA-A0124-110. 2C2 (inside the UK replace + 44 with 0) email to: more@dcsltd. co. uk web site: www. dcsltd. co. uk dCS ADP8322 User Manual dCS Ltd Manual for Software Version 2. 3x January 2001 Multi-channel Sample Rate Conversion ­ with more alignment tolerance WORDCLOCKS TO SOURCES AES 1 more@dcsltd. co. uk AES 2 AES 3 AES 4 1 2 3 4 5 6 In Mains Fuse (2AT) On Off W ordclock Outputs AES/EBU Outputs 7 8 9 10 11 12 External Sync Loop Out Remote A AES1 PUSH C AES2 PUSH dCS 992 Master Clock AES2 AES CLK In Rem ote 96kS/s Ch1 & 2 AES CLK PUSH AES1 SDIF-2 Inputs CH1 CH2 CLK AES / EBU Inputs AES / EBU Outputs Out MAINS FUSE 2A(T) ON OFF SDIF-2 Outputs SPDIF Outputs SPDIF Inputs FROM SOURCE SPDIF1 SPDIF2 SPDIF3 SYNC IN CH1 CH2 CLK 96kS/s Ch3 & 4 AES1 PUSH AES2 PUSH AES CLK PUSH AES1 SDIF-2 Inputs CH1 CH2 CLK AES2 AES CLK In Rem ote MAINS FUSE 2A(T) ON AES / EBU Inputs AES / EBU Outputs Out OFF SPDIF1 SPDIF Inputs SPDIF2 SPDIF3 SYNC IN CH1 CH2 CLK SPDIF Outputs SDIF-2 Outputs 96kS/s Ch5 & 6 AES1 PUSH AES2 PUSH AES CLK PUSH AES1 SDIF-2 Inputs CH1 CH2 CLK AES2 AES CLK In Rem ote MAINS FUSE 2A(T) ON AES / EBU Inputs AES / EBU Outputs Out OFF SDIF-2 Outputs SPDIF Outputs SPDIF Inputs FROM SOURCE SPDIF1 SPDIF2 SPDIF3 SYNC IN CH1 CH2 CLK 96kS/s Ch7 & 8 AES1 PUSH AES2 PUSH AES CLK PUSH AES1 SDIF-2 Inputs CH1 CH2 CLK AES2 AES CLK In Rem ote AES / EBU Inputs AES / EBU Outputs Out SPDIF3 CH2 CLK Figure 11 ­ Multi-channel Sample Rate Conversion with more alignment tolerance A dCS 992 Master Clock can also be used to sync up the source and the dCS ADP8322 units as above. In addition to the sync link cabling (starting with "A"), additional clocking (cables "C") allow the dCS ADP8322's to extract clocks from the "C" cables and extract the data from the signal input cables. The master clock outputs different frequencies on the different cabling types. This allows considerable bit alignment error, as might occur if some tracks are stored on one machine and some on another. Make sure that all the other settings are the same on each unit. 14 14 version 2. 0 or higher software Manual part no: DOC1241102C2 Contact dCS on + 44 1799 531 999 Page 54 Document No: OS-MA-A0124-110. 2C2 (inside the UK replace + 44 with 0) email to: more@dcsltd. co. uk web site: www. dcsltd. co. uk dCS ADP8322 User Manual dCS Ltd Manual for Software Version 2. 3x January 2001 Multi-channel Sample Rate Conversion ­ with multiple sample rates out AES1 PU SH AES2 PU SH AES CLK PU SH AES2 AES / EBU Inputs AES / EBU Ou tputs CH1 CH2 CLK SDIF-2 Inputs Out Rem ote MAINS F USE 2A(T) ON OFF SPDIF 1 SPDIF2 SPDIF3 SYNC IN CH1 CH2 CLK SDIF -2 Outputs SPDIF Outputs SPDIF In puts 48kS/s Ch19 & 20 AES1 PU SH AES2 PU SH AES CLK PU SH AES1 CH1 CH2 CLK AES2 AES CLK In SDIF-2 Inputs AES / EBU Inputs AES / EBU Ou tputs Out Rem ote MAINS F USE 2A(T) ON OFF SPDIF 1 SPDIF2 SPDIF3 SYNC IN CH1 CH2 CLK SDIF -2 Outputs SPDIF Outputs SPDIF In puts 48kS/s Ch17 & 18 AES1 PU SH AES2 PU SH AES CLK PU SH AES1 CH1 CH2 CLK AES2 AES CLK In SDIF-2 Inputs AES / EBU Inputs AES / EBU Ou tputs Out Rem ote MAINS F USE 2A(T) ON OFF SPDIF 1 SPDIF2 SPDIF3 SYNC IN CH1 CH2 CLK SDIF -2 Outputs SPDIF Outputs SPDIF In puts FROM SOURCE AES / EBU Inputs 48kS/s Ch15 & 16 AES1 PU SH AES2 PU SH AES CLK PU SH AES1 CH1 CH2 CLK AES2 AES CLK In SDIF-2 Inputs AES / EBU Ou tputs Out Rem ote MAINS F USE 2A(T) ON OFF SDIF -2 Outputs W ordclock Outputs more@dcsltd. co. uk AES/EBU Outputs TO RECORDER (44. 1kS/s WORDCLOCK) B AES 1 AES 2 AES 3 AES 4 1 2 3 4 5 6 In Mains Fuse (2AT) On Off SPDIF Outputs SPDIF 1 SPDIF2 SPDIF3 SYNC IN CH1 CH2 CLK SPDIF In puts 48kS/s Ch13 & 14 External Sync Loop Out Remote 7 8 9 10 11 12 A AES1 PU SH dCS 992 Master Clock AES2 PU SH 96kS/s Ch1 & 2 AES CLK PU SH AES1 CH1 CH2 CLK AES2 AES CLK In SDIF-2 Inputs AES / EBU Inputs AES / EBU Ou tputs Out Rem ote MAINS F USE 2A(T) ON OFF SDIF -2 Outputs SPDIF Outputs SPDIF In puts FROM SOURCE SPDIF 1 SPDIF2 SPDIF3 SYNC IN CH1 CH2 CLK 96kS/s Ch3 & 4 AES1 PU SH AES2 PU SH AES CLK PU SH AES1 CH1 CH2 CLK AES2 AES CLK In SDIF-2 Inputs AES / EBU Inputs AES / EBU Ou tputs Out Rem ote MAINS F USE 2A(T) ON OFF SPDIF 1 SPDIF2 SPDIF3 SYNC IN CH1 CH2 CLK SDIF -2 Outputs SPDIF Outputs SPDIF In puts 96kS/s Ch5 & 6 AES1 PU SH AES2 PU SH AES CLK PU SH AES1 CH1 CH2 CLK AES2 AES CLK In SDIF-2 Inputs AES / EBU Inputs AES / EBU Ou tputs Out Rem ote MAINS F USE 2A(T) ON OFF SPDIF 1 SPDIF2 SPDIF3 SYNC IN CH1 CH2 CLK SDIF -2 Outputs SPDIF Outputs SPDIF In puts 96kS/s Ch7 & 8 AES1 PU SH AES2 PU SH AES CLK PU SH AES1 CH1 CH2 CLK AES2 AES CLK In SDIF-2 Inputs AES / EBU Inputs AES / EBU Ou tputs Out SPDIF3 CH2 CLK Figure 12 ­ Multi-channel Sample Rate Conversion with multiple sample rates out Manual part no: DOC1241102C2 Contact dCS on + 44 1799 531 999 Page 55 Rem ote Document No: OS-MA-A0124-110. 2C2 (inside the UK replace + 44 with 0) email to: more@dcsltd. co. uk web site: www. dcsltd. co. uk dCS ADP8322 User Manual dCS Ltd Manual for Software Version 2. 3x January 2001 A dCS 992 Master Clock can also be used to sync up the source and more than one set of units, all at different sample rates, and be the master. DVD production may require different sample rates for different channels ­ this set up will give real time 48 kS/s rear channels and 96 kS/s front channels from a multichannel 44. 1kS/s source. Make sure that all the other settings are the same on each unit in a group. 15 15 version 2. 0 or higher software Manual part no: DOC1241102C2 Contact dCS on + 44 1799 531 999 Page 56 Document No: OS-MA-A0124-110. 2C2 (inside the UK replace + 44 with 0) email to: more@dcsltd. co. uk web site: www. dcsltd. co. uk dCS ADP8322 User Manual dCS Ltd Manual for Software Version 2. 3x January 2001 Manual part no: DOC1241102C2 Contact dCS on + 44 1799 531 999 Page 57 Document No: OS-MA-A0124-110. 2C2 (inside the UK replace + 44 with 0) email to: more@dcsltd. co. uk web site: www. dcsltd. co. uk dCS ADP8322 User Manual dCS Ltd Manual for Software Version 2. 3x January 2001 dCS ADP8322 TECHNICAL INFORMATION DSD Filter Options DSD is a single bit very high sample rate (2. 822 MS/s) format, where the single bit words are heavily noise shaped to push noise energy above audio. The frequency response is very high (well above 100 kHz) although at these high frequencies noise is also present. [. . . ] If you are interested in these, please do not hesitate to contact us. Manual part no: DOC1241102C2 Contact dCS on + 44 1799 531 999 Page 105 Document No: OS-MA-A0124-110. 2C2 (inside the UK replace + 44 with 0) email to: more@dcsltd. co. uk web site: www. dcsltd. co. uk dCS ADP8322 User Manual dCS Ltd Manual for Software Version 2. 3x January 2001 INDEXES AND SOFTWARE VERSION NUMBERS This manual is for software version 2. 3x. v2. 3x ­ much enhanced DSD modulator options, and SDIF-3 for DSD v2. 2x - multi-channel syncing facilities, change in the level drop from 0. 1dB to 0. 01dB in sample rate conversion mode, enhanced level metering facilities, and operation of the RS-232 interface to give "lid on" software updating. V1. 54 ­ major update Definitions of Units dB0 dB0DSD Level in decibels, referred to a full scale sine wave in a sampled system. Level in decibels, referred to the defined full scale sine wave in a DSD system. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DIPLOMAT ADP8322




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DIPLOMAT ADP8322 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.