User manual DEVILLE C07922 05-10

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DEVILLE C07922. We hope that this DEVILLE C07922 user guide will be useful to you.


DEVILLE C07922 05-10: Download the complete user guide (4328 Ko)

You may also download the following manuals related to this product:

   DEVILLE C07922 VUE ECLATEE 01-07-03 (472 ko)

Manual abstract: user guide DEVILLE C0792205-10

Detailed instructions for use are in the User's Guide.

[. . . ] 2 Characteristics and size of the smoke flue to which the appliance must be connected 5. 5 ­ Ventilation of the area in which the appliance is to be installed 5. 2 Building in dimensions ­ Protection of walls and casings made of combustible materials or which are affected by heat ­ Convection system 5. 2 - Installation in an existing fireplace built with refractory materials and initially made to be an open hearth 5. [. . . ] Ensure the minimum embedding dimensions and put in the convection system, as shown in Figure 11 (casing to be built around the stove). - If the space is big enough, insert the pipe in the noozle placing the hands between between the upper part of the appliance et the base of the collar . - If there is not space enough above the appliance to place there the hands, the insertion of the pipe can be done easily in putting first in this piece of pipe at about ten centimetres from its base a broach which will allow to seize the the pipe to insert it on the noozle passing the hand from the inside of the appliance. This broach can stay there without hampering the working of the appliance (Fig. NOTA : The connecting pipe and the collar will have to be made of stainless steel with a minimum thickness of 0, 4 mm . The sketches 18 and 19, given as example, represent 2 cases of common installations: - Fig. Possibility of hot air release through the head and the existing hood. The design, condition or sizes of the chimney do not allow to a hot air release through the chimney head. The appliance must be set up on a floor with a sufficient bearing capacity. If the existing construction does not comply with this prior requirement, appropriate measures must be taken to allow the floor to bear the appliance, such as setting up a load distribution plate. The connection method shown is the most common one : Connection to a masonry flue connected to the ceiling by a special fixing device. A hot air outlet with a minimum section of 800 cm should be installed at the front or sides, at least 300 mm from the ceiling, to expel the heat and reduce the inside temperature of the structure. A hot-air release vent can also be installed in the room behing the fireplace or upstairs on the room above see paragraph hot-air distribution. 1 ­ General Operation to be made Lighten the heating body to make it easy its installation in the fireplace, to do so remove the polystyrene wedges holding the deflector, take of the deflector, the cast iron parts that are inside the appliance and the door (see paragraph 7. 2 ­ Setting up of the appliance Once the appliance installed in the fireplace, put back all the removed parts: to do so proceed in the reverse order of the dismounting. 2 - Installation in an existing fireplace built with refractory materials and initially made to be an open hearth Connection with the chimney (see example Fig. 14) : · It is necessary to smoke-tight obstruct the base of the smoke flue . LIGHTING DAMPER The lighting postion is obtained through moving the damper directly with the hand : this position can only be used when the appliance is `cold' and in making the following operations (Fig. Operation n° : 3 Maintain the damper in its high position and push it to the right : you are in ` lighting position'. After the building of the fireplace and the setting up of the appliance, a drying period of the materials used for the work has to be respected (2 to 3 weeks). 1), make a moderate fire in the first hours limiting the loading in the appliance (a log of 15 cm) with the air intake damper in an intermediate position (Fig. 20) : progressive rise in temperature of all the elements of the fireplace and normal expansion of the appliance. [. . . ] Proceed successively through the loosening of the screw and the screwing down of . Proceed successively through the loosening of the screw and the screwing down of . TERMS AND CONDITIONS Apart from the legal warranty, particularly for latent defects, Deville guarantees to deliver the furniture in case of obvious defects or non-conformity to the ordered furniture. Without prejudice to the provisions that are to be taken concerning the carrier, claims on delivery of furniture concerning the obvious defects or the non conformity, must be issued by the Buyer in writing a registered letter with confirmation of receipt to Deville company with in 5 days after noticing the defect. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DEVILLE C07922




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DEVILLE C07922 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.