User manual DELONGHI PAC WE18INV

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DELONGHI PAC WE18INV. We hope that this DELONGHI PAC WE18INV user guide will be useful to you.


DELONGHI PAC WE18INV : Download the complete user guide (4371 Ko)

Manual abstract: user guide DELONGHI PAC WE18INV

Detailed instructions for use are in the User's Guide.

[. . . ] AIR CONDITIONER INSTRUCTIONS 1 IMPORTANT SAFEGUARDS · Usethisapplianceonlyasdescribedinthis instructionmanual. As with all electrical equipment, whilst the instructionsaimtocoverasmanyeventualitiesaspossible, cautionandcommonsense shouldbeappliedwhenoperatingandinstallingthisappliance. · Thisapplianceisdesignedforhomeairconditioningandmustnotbeusedforotherpurposes. · Itisdangeroustomodifyoralterthecharacteristicsoftheapplianceinanyway. [. . . ] "CF" is displayed when the limescale filter needs replacing. The efficacy of the filter depends on water hardness. · Immersethepapercompletelyinaglassof waterforonesecond. After about a minute, 1, 2, 3, 4 or 5 red squares appear, depending on the hardnessofthewater. Theappliancecanbe set to three different water hardness levels soft(H1), medium(H2)andhard(H3). Determinethehardnessofthewateryouwillbe usingbycomparingtheredsquaresonthe indicatorpaperwiththetablebelow. Kind of water used 19 soft Levels H1 20 Medium H2 Hard H3 Tosetwaterhardness, proceedasfollows: 1. Hold the FAN button on the control panel downfor10seconds. Theapplianceemitsa beepandH1, H2 orH3isdisplayed. Use the + or - buttons to set the hardness levelaccordingtothetableabove. Waitafew secondsforthesettingtobememorized. The applianceemitsanotherbeepandgoesback tostand-by. The water tank is located at the bottom of the appliance. Extractthetankbyinsertingthehand through the door above the word "PULL" (fig. Removethecapanduseacontainer(bottle, jug, wateringcan)topourinthewater(fig. 14/15). Youcanseewhenthetankisfullthroughthefil7 Filling the tank Setting water hardness Measurewaterhardnessusingtheindicatorpaperprovided. · Removetheindicatorpaperfromitspack(V). linghole. Itholdsamaximumof10litres. 13 14 1 2 15 Turn the appliance off and unplug from the mains. Makesurethereisnowaterintheapplianceby emptyingthetankandinternaltrayasdescribed inthesection:"Endofseasonoperations". Rest it on a towel or piece of cardboard to avoidscratchesordamage. Removethefiltercoverbyunscrewingthefourscrews(fig. 17). Removethefilter delicately and loosen thetwo ties, makingsurethetwohosesconnectingthe filterdonotslipinsidetheappliance. Fitthenew filter, following the same procedure in reverse (fig. Tosetthismodecorrectly: · Press the MODE button a number of times Air conditioning mode (fig. 21) 16 13 13 In this mode, fan speed is selected automatically by the appliance and cannot be set manually. 15 untiltheair-conditioningsymbolappears. 5 · Select the target temperature by pressing 14 the orbuttonuntilthecorresponding valueisdisplayed. Fourspeedsareavailable: 12 22 15 Maximum speed: toachievethetarget temperatureasrapidlyaspossible15 Medium speed: reduces noise levels butstillmaintainsagoodlevelofcomfort 11 16 19 Low speed:forsilentoperation 20 123 4 AUTOFAN: the appliance automatically selectsthemostsuitablefanspeedinrelationto 21 thetemperaturesetonthedigitaldisplay. 6 The most suitable temperature for the room during the summer varies from 24 to22 27°C. You are recommended, however, not 7 set a to temperature much below the outdoor tempera9 ture. 21 13 14 17 18 24 11 15 Medium speed: reduces noise levels 16 butstillmaintainsagoodlevelofcomfort. High speed: formaximumfanpower When using the appliance in this mode, the air hosedoesnotneedtobeattached. 5 Tosetthismodecorrectly: · Press the MODE button a number of times untilthefansymbolappears. 23) 19 Minimum speed: forsilentoperation In this mode, AUTO speed cannot be selected. 20 23 21 22 Ideal to reduce room humidity (spring and autumn, damprooms, rainyperiods, etc). Indehumidifyingmode, theapplianceshouldbe preparedinthesamewayasforairconditioning, withtheairexhausthoseattachedtoenablethe moisturetobedischargedoutside. Tosetthismodecorrectly: · Press the MODE button a number of times untilthedehumidifyingsymbolappears. Dehumidifying mode (fig. 22) 23 10 SMARTmodetriestorecreateidealcomfortconditionsintheroom. Theapplianceautomatically establishes whether to operate in air conditioning, fan or stand-by mode depending on the environmentalconditionsdetected. [. . . ] Ifthealarmpersistsandtheappliancedoesnotwork, unplugtheappliance, thenplug itagain. Ifthealarmpersistsandtheappliancedoesnotwork, unplugtheappliance, thenplug itagain. Ifthealarmoccursagain, contactyourlocalauthorisedcustomerservices. 15 Failure 1 Failure 2 (invertermodulefailure) Failure 3 (communicationfailure) Togetthebestfromyourairconditioner, follow theserecommendations: · closethewindowsanddoorsintheroomto beairconditioned(fig. 34). Wheninstallingtheairconditionersemi-permanently, you should leave a door slightly open(aslittleas1cm)toguaranteecorrect ventilation. TIPS FOR CORRECT USE 36 34 donotcover theappliance · makesuretheairconditionerisstandingon alevelsurface. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PAC WE18INV




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI PAC WE18INV will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.