User manual DELONGHI PACT 140HPEC

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DELONGHI PACT 140HPEC. We hope that this DELONGHI PACT 140HPEC user guide will be useful to you.


DELONGHI PACT 140HPEC : Download the complete user guide (2442 Ko)

You may also download the following manuals related to this product:

   DELONGHI PACT 140HPEC (2238 ko)
   DELONGHI PACT 140HPEC (2260 ko)

Manual abstract: user guide DELONGHI PACT 140HPEC

Detailed instructions for use are in the User's Guide.

[. . . ] AIR CONDITIONER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS CLIMATISEUR MODE D'EMpLOI CONSERVEZ CE MODE D'EMpLOI CLIMATIZADOR INSTRUCCIONES DE USO CONSERVE ESTAS INSTRUCCIONES LEA CUIDADOSAMENTE ESTE INSTRUCTIVO ANTES DE USAR SU ApARATO pAC T140HpEC Register this product online and receive a free trial issue of Cook's Illustrated. Only) Enregistrez ce produit en ligne et recevez un numéro gratuit de Cook's Illustrated. Visitez www. delonghiusa. com pour y voir une liste des centres de réparation proches de chez vous. uniquement) Registre este producto en línea y reciba un ejemplar gratis de Cook's Illustrated. [. . . ] In this mode, the appliance decides automatically whether to operate in air conditioning, fan or heating mode, the most suitable temperature for optimum well-being and the fan speed. SMART MODE (FIG. 16) 16 9 REMOTE CONTROL DESCRIpTION 3 2 USING THE REMOTE CONTROL MAX. 23 feet 4 1 5 6 9 8 7 12 10 13 16 17 11 14 15 19 21 20 18 22 · pointtheremotecontrolatthereceiveron theappliance. Theremotecontrolmustbe no more than 23 feet away from the appliance (without obstacles between the remote control and the receiver). · Theremotecontrolmustbehandledwith extreme care. Donotdropitorexposeitto direct sunlight or sources of heat. INSERTING OR REpLACING THE BATTERIES · removethecoverontherearoftheremote control (fig. 17); · Insert two r03 "AAA" 1. 5V batteries in the correct position (see instructions inside the battery compartment); · replacethecover. 24 23 25 17 1 Air conditioning symbol 2 Dehumidifyingsymbol 3 fansymbol 4 Heating symbol 5 SMArTsymbol 6 Signal transmission 7 Selected temperature scale indicator 8 Relative humidity indicator 9 SLEEP symbol 10 AUTofanspeedindicator 11fanspeedindicator 12 Clock 13Timeronsymbol 14Timeroffsymbol 15 MoDebutton(selectsthemodes) 16on/Standbybutton 17fAnbutton 18 Increase (+) and decrease (-) button 19 Reset button (resets the factory default settings) 20Timeronbutton 21 SeTbutton 22 Timeroffbutton 23 SWInGbutton 24 SLEEP button 25°Cor°fselectionbutton If the remote control unit is replaced or discarded, the batteries must be removed and disposed of in accordance with current legislation as they are harmful to the environment. Do not mix alkaline, standard (carbon-zinc) or rechargeable (nickel-cadmium) batteries. If the remote control is not be used for a certain length of time, remove the batteries. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These 10 limits are designed to provide reasonable protection against harmful interference in a residential installation. · This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. SETTING THE TIME After having inserted the batteries, the clock on thedisplayflashesuntilthetimeisset. Proceed as follows: · pressthe+or-buttonuntilthecorrecttime is reached. Hold the button down to run rapidly through first the minutes, then the tens of minutes and then the hours. · once the correct time has been reached, press the SET button to confirm. If you need to change the time later, press the SET button, thensetasdescribedabove. Tocancelthe settings programmed on the remote control and restore the original settings, press the RESET button lightly with the point of a pencil or pen. 11 USING THE REMOTE CONTROL (FIG. 18) The ON/Standby, MODE, FAN, + and - buttons correspond to the equivalent buttons on the control panel. MODE button: Selects modes AIr ConDITIonInG, DehUMIDIfyInG, AIr pUrIfyInG, fAn, heATInG, SMArT FAN button: selects fan speed (High, Medium, Quiet, Auto) + and - button: increase and decrease. [. . . ] The water should never be hotter than 105°f (40°C). 15 TROUBLESHOOTING pROBLEM The air conditioner does not come on CAUSE · · · · noelectricity itisnotpluggedintotheoutlet theinternalsafetydevicehastripped thesafetydeviceoftheplughastripped. therearebendsorkinksintheair exhaust hose somethingispreventingtheairfrom being discharged windows, doorsand/orcurtainsopen thereareheatsourcesintheroom (oven, hairdryer, etc) theairexhausthoseisdetachedfrom the appliance SOLUTION · · · · · · · · · · restoreelectricity plugintotheoutlet wait30minutes, iftheproblempersists contact your service center resetthesafetyplug position the air hose correctly, keeping it as short and free of curves as possible to avoid bottlenecks checkandremoveanyobstacles obstructing air discharge closedoors, windowsandcurtains, bearing in mind the "TIpSfor CorreCTUSe"givenabove eliminatetheheatsources fittheairexhausthoseinthehousingat the back of the appliance (fig. 1) cleanthefiltersasdescribedabove The air conditioner works for a short time only The air conditioner works, but does not cool the room · · · · · · silver ion and 3M® filter clogged ·thetechnicalspecificationofthe appliance is not adequate for the room in which it is located. During operation, there is an unpleasant smell in the room ·silverionand3M®filterclogged. · cleanthefiltersasdescribedabove The air conditioner does not operate for about three minutes after restarting it The following message appears on the display: LT / Ft/PF / FI · theinternalcompressorsafetydevice prevents the appliance from being restarted until three minutes have elapsed since it was last turned off. · wait. Thisdelayispartofnormal operation. · Theappliancehasaselfdiagnosis system to identify a number of malfunctions. · SeetheSelf-DIAGnoSISchapter. 16 TECHNICAL SpECIFICATIONS Outlet voltage Maximum absorbed power in air conditioning Maximum absorbed power in heating Refrigerant Cooling capacity Heating power see rating plate " " " " " This appliance is equipped with a 3 prong grounded plug. The plug must be connected into an outlet that is properly installed and grounded in the accordance with all local codes and ordinances. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PACT 140HPEC




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI PACT 140HPEC will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.