User manual DELONGHI PACN 125HP

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DELONGHI PACN 125HP. We hope that this DELONGHI PACN 125HP user guide will be useful to you.


DELONGHI PACN 125HP : Download the complete user guide (604 Ko)

Manual abstract: user guide DELONGHI PACN 125HP

Detailed instructions for use are in the User's Guide.

[. . . ] · Do not install the appliance in rooms containing gas, oil or sulphur. · Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pressu rised containers (eg aerosol cans). · Always transport the appliance upright or resting on one side. Before moving the appliance, empty the internal circuit completely of water. [. . . ] 134 5, 27 in. 2 1 in the window pane in the wooden kickboard of a French window in the wall: you are recommended to insulate the section of wall using suitable insulation. F · Open the French window slightly and position the outlet 20 as shown in figure G I · Fit the wall flange 11 into the hole. · Screw the hose 12 to the adaptor 13 , that was already fitted to the appliance (fig. · Remove the L plastic end of the hose 1 12 by unscrewing it and in its 2 place screw the wall mounting accessory 14 (fig. · Fit the end of the hose 12 to the wall flange 11 as shown in fig. M. G Keep the air hoses as short and free of curves as possible to avoid constrictions. SEMI-PERMANENT INSTALLATION If required, your appliance can also be installed semi-permanently (Fig. H). MAX100 cm MAX 39, 37 inches MIN 35 cm MAX 13, 77 inches M When the hose 12 is not fitted, the hole can 30 cm H be closed with the flange cap 30 cm 11 . Proceed as follows: · Drill a hole (ø134mm / 5, 27 in. ) in an outside wall or through a window pane. Respect the height and dimensions of the hole given in figures M and I. NOTE: When installing the air conditioner semi-permanently, you should leave a door slightly open (as little as 1 cm) to guarantee correct ventilation. 6 Control panel THE CONTROL PANEL S Q O P N I T L M H G A B C R D E F DESCRIPTION OF THE CONTROL PANEL A ON/OFF button B MODE selection button Air conditioning, dehumidifying, fan, heating. C Fan speed selection button (MAX/MED/MIN) D Timer button E Programmed operation increase temperature/time button F Programmed operation decrease temperature/time button G Display Displays the temperature values set and the programmed operating time H Timer in operation indicator light I/L/M Fan speed lights N Fan/Heat mode light O Air-conditioning mode light P Dehumidifying mode light Q Alarm light R Remote control receiver S Light: the inner temperature is shown on the display T Light: the set temperature is shown on the display Never turn the air conditioner off by unplugging from the outlet. Always press the button, then wait for a few minutes before unplugging. This allows the appliance to perform a cycle of checks to verify operation. 7 Operation TURNING THE APPLIANCE ON Plug into an outlet. Two lines appear on the display indicating that the appliance is in stand-by. When turned on, the air conditioner starts operating in the same mode as when it was turned off. Press the MODE button (B) until the light corresponding to the desired mode lights up: Light (O): air-conditioning mode Light (P): dehumidifying mode Light (N): fan/heating mode (the light changes colour from yellow to red) AIR CONDITIONING MODE Ideal for hot muggy weather when you need to cool and dehumidify the room. To modify the set temperature, push the (E) or (F) button to reach the desired temperature. (To change from °F to °C or viceversa, press for few seconds both button E and F). Then select the fan speed by pressing the FAN button (C) until the light corresponding to the required fan speed lights up: MAX: the air conditioner operates at maximum to achieve the target temperature as rapidly as possible MED: reduces noise levels while maintaining a comfortable temperature MIN: for silent operation The most suitable temperature for the room during the summer varies from 75°F to 81°F (24 to 27°C). You are recommended, however, not to set a temperature much below the outdoor temperature FAN MODE Adjust fan speed by pressing the FAN button (C) as described for the air-conditioning mode. If you select "MIN" speed, less air is filtered but the appliance is also less noisy. 8 Operation HEATING MODE This is ideal in spring and autumn when outdoor temperatures are not particularly severe. When using the appliance in this mode, the air hose must be be attached. To set this mode correctly: · Press the MODE button a number of times until the red light appears. · Select the target temperature by pressing the + or - button until the corresponding value is displayed. DEHUMIDIFYING MODE Ideal for reducing the humidity in a room without lowering or raising the temperature (spring or autumn, damp rooms, rainy spells, etc). In this mode, other speeds cannot be selected. PROGRAMMING THE TIMER The timer can be used to delay appliance start up or shut down. [. . . ] (After the unit has been on its side, oil needs to return to the compressor to ensure proper function. Without allowing the unit this time (6-24 hours) The unit may function for only a short time, and then the compressor will break down from lack of oil. ) TROUBLESHOOTINGn PROBLEM The air conditioning unit does not start. Contact your service center. The air conditioning unit works for a short time only. · · · · · The air conditioner works, but does not cool the room. · · · · · There are tight bends in the air exhaust hose. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PACN 125HP




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI PACN 125HP will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.