User manual DELONGHI PACFX 400ECO

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DELONGHI PACFX 400ECO. We hope that this DELONGHI PACFX 400ECO user guide will be useful to you.


DELONGHI PACFX 400ECO : Download the complete user guide (396 Ko)

You may also download the following manuals related to this product:

   DELONGHI PACFX 400ECO (391 ko)
   DELONGHI PACFX 400ECO (391 ko)
   DELONGHI PACFX 400ECO (610 ko)
   DELONGHI PACFX 400ECO (388 ko)
   DELONGHI PACFX 400ECO (390 ko)
   DELONGHI PACFX 400ECO (394 ko)

Manual abstract: user guide DELONGHI PACFX 400ECO

Detailed instructions for use are in the User's Guide.

[. . . ] If this is not possible secure the unit at an angle, do not lie horizontally. Before transporting the unit drain the condensation collectingtray and tank. Avoid transportation, wait at least 1 hour before switching on the unit. You are therefore recommended to place them in the special containers for differentiated waste collection. [. . . ] Attention We recommend that disconnection and reconnection of the quick couplings be carried out by qualified personnel. PREPARING THE EXTERNAL UNIT The external unit can be placed on a terrace or balcony. FX400ECO) 3) Attach the external unit to the brackets, fixing it with the M6 screws. (17) 2 14 1 Alternatively, for temporary installation, the external unit can be suspended as shown in fig. In this case, use the belts (14) supplied; hook these to the eyes (15); before inserting the eyes, remove the rubber seals. 15 11 The external unit can also be hung on a wall using the brackets (12). Proceed as follows: 1) FFix the bracket to the wall 12 taking care to position it as indicated in fig. (For the holes, use the jig on the cover of the polystyrene packaging); The external unit may be installed above or at the same level as the internal unit, provided that the difference in level is not greater than 1. 5m. the air intake and discharge of the external unit must be kept clear of obstacles. Condensation forming during operation is eliminated via evaporation from the external unit. In particular cases, if there is excessive humidity, to eliminate condensation the drain coupling must be used. The external 16 unit should be protected from the sun, rain, snow and Wheel drips from the roof. Coupling 27 ENGLISH 2) Screw the support blocks (13) to the external unit using the M4 screws (17) (taking care to position them with the hole for the screw on top). 13 FX160/400ECO GB 20-06-2002 16:51 Pagina 28 Description of the control panel THE DISPLAY A. Display Displays the temperature selected, time programmed and (Model FX400ECO only) the room temperature. Display room temperature button (FX400ECO) ELECTRICAL CONNECTION Before plugging in check that: · the mains supply corresponds to the value shown in the specifications table; · the socket and the mains lead correspond to the power requirements of the appliance; · the socket is suited to the plug, otherwise have the socket replaced; · the socket is properly grounded. The manufactures cannot be held responsible for any damages due to failure in following normal safety procedures. Replacement of the power cable must be carried out by qualified personnel. 28 FX160/400ECO GB 20-06-2002 16:51 Pagina 29 Operation SWITCHING THE APPLIANCE ON Connect the appliance to the mains supply. The appliance will automatically select the correct fan mode. 29 ENGLISH FX160/400ECO GB 20-06-2002 16:51 Pagina 30 Operation VENTILATION/PURIFICATION This is ideal for dusty or polluted areas; in effect, the appliance recycles and purifies the air using the dust filters and 3M FiltreteTM electrostatic filters fitted. Adjust the fan speed by pressing the "FAN" (Q) button, as illustrated in the air conditioning function. Bear in mind that the higher the speed, the greater the volume of air filtered; by selecting the "Silent" speed, less air is filtered, but the noise level is low. "Silent" speed "Min" speed PROGRAMMING THE TIMER The timer programs the appliance to switch on and switch off. The timer is set using the buttons + (F) or ­ (G); these increase and decrease by one hour at a time, but if pressed for more than 2 seconds will automatically change the time more quickly, up to a maximum of 24 hours. How to set the delayed start function · Connect the appliance to the mains supply and press ON/OFF button: next, select the required operating mode (temperature, fan speed etc. ) · Press the ON/OFF button again: the appliance will go into stand-by mode. · Press the timer button (1): on the display the two central segments will start to flash. [. . . ] If it does not fit your socket, the plug should be cut off from the mains lead, and on appropriate plug fitted, as below. warning: Very carefully dispose of the cut off plug after removing the fuse: do not insert in a 13 Amp socket elsewhere in the house as this could cause a shock hazard. With alternative plugs not incorporating a fuse, the circuit must be protected by a 15 Amp fuse. If the plug is a mouldedon type, the fuse cover must be re-fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PACFX 400ECO




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI PACFX 400ECO will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.