User manual DELONGHI PAC A95

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DELONGHI PAC A95. We hope that this DELONGHI PAC A95 user guide will be useful to you.


DELONGHI PAC A95 : Download the complete user guide (1475 Ko)

You may also download the following manuals related to this product:

   DELONGHI PAC A95 (1530 ko)
   DELONGHI PAC A95 (1506 ko)
   DELONGHI PAC A95 (1485 ko)
   DELONGHI PAC A95 (1477 ko)
   DELONGHI PAC A95 (1476 ko)
   DELONGHI PAC A95 (1477 ko)
   DELONGHI PAC A95 (1505 ko)
   DELONGHI PAC A95 (1941 ko)
   DELONGHI PAC A95 (1477 ko)
   DELONGHI PAC A95 (1359 ko)
   DELONGHI PAC A95 (1508 ko)
   DELONGHI PAC A95 (1477 ko)
   DELONGHI PAC A95 (1509 ko)
   DELONGHI PAC A95 (1382 ko)
   DELONGHI PAC A95 (1474 ko)
   DELONGHI PAC A95 (1502 ko)
   DELONGHI PAC A95 (1227 ko)
   DELONGHI PAC A95 BROCHURE (74 ko)

Manual abstract: user guide DELONGHI PAC A95

Detailed instructions for use are in the User's Guide.

[. . . ] · Before cleaning or maintenance, always unplug the appliance from the mains socket. · Do not install the appliance in rooms containing gas, oil or sulphur. · Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pressurised containers (e. g. [. . . ] F. 2 1 F 19 Pre p a r i n g f o r u s e AIR CONDITIONING WITH INSTALLATION If required, your appliance can also be installed semi-permanently (Fig. · Fit the adapter 13 to the air exhaust hose housing 7 at the back of the appliance (see fig. · Screw the wall mounting accessory unscrew the adapter exhaust hose 12 wall installation terminal 13 14 to the air exhaust hose 12 or, if necessary, from the air and replace it with the 14 (fig. L). 30 cm 30 cm 1 2 L · Fit the end of the hose 12 to the flange 11 H Proceed as follows: · Drill a hole (dia. M. MAX100 cm 134 MIN 35 cm in the window pane I in the wooden kickboard of a French window in the wall: you are recommended to insulate the section of wall using suitable insulation. M When the hose 12 is not fitted, the hole can be closed with the flange cap 11 . PLEASE NOTE: When installing the air conditioner semi-permanently, you should leave a door slightly open (as little as 1 cm) to guarantee correct ventilation. Keep the air hoses as short and free of curves as possible to avoid bottlenecks. 20 Control panel EN THE CONTROL PANEL G H I L A B D E °C °F C F S RQ P O NM DESCRIPTION OF THE CONTROL PANEL A ON /OFF button B MODE selection button Air conditioning, dehumidifying, fan C Reduce temperature/programme mode time button D Timer button E Fan speed button (MAX/MED/MIN) F Increase temperature/programme mode time button G Air conditioning symbol H Dehumidifying symbol I Fan symbol L Alarm symbol M Fan speed indicator N Temperature scale indicator O Time indicator P Set temperatures, room temperature and programmed on/off time Q Timer symbol R Room temperature symbol S Set temperature symbol Never turn the air conditioner off by unplugging from the mains. Always press the button, then wait for a few minutes before unplugging. This allows the appliance to perform a cycle of checks to verify operation 21 Operation TURNING THE APPLIANCE ON Plug the appliance into the mains. Two lines appear on the display indicating that the appliance is in stand-by. The first time the appliance is turned on, it will be in air conditioning mode. When turned on subsequently it will be in the same mode as when last turned off. Press the MODE button (B) until the symbol corresponding to the required mode is displayed: Air conditioning symbol (G) Dehumidifying symbol (H) Fan symbol (I) AIR CONDITIONING MODE Ideal for hot muggy weather when you need to cool and dehumidify the room. To set this function correctly: · Press the MODE button a number of times until the air conditioning symbol appears. · Select the target temperature by pressing the button (F) or button (C) until the required value is displayed. There are 3 speeds available: High speed: to achieve the target temperature as rapidly as possible Medium speed: reduces noise levels but still maintains a good level of comfort Low speed: for silent operation °C °C The most suitable temperature for the room during the summer varies from 24 to 27°C. You are recommended, however, not to set a temperature much below the outdoor temperature. 22 Operation EN DEHUMIDIFYING MODE Ideal to reduce room humidity (spring and autumn, damp rooms, rainy periods, etc). For this mode, the appliance should be prepared in the same way as for air conditioning, with the air exhaust hose attached to enable the moisture to be discharged outside. To set this function correctly: · Press the MODE button a number of times until the dehumidifying symbol appears. °C NOTE: In this mode, with room temperature above 25 degree C, the fan speed is adjustable. [. . . ] Clean the filter and dry thoroughly before putting back. N O 27 Troubleshooting PROBLEM The air conditioner does not come on · · · CAUSE there is no current the appliance is not plugged into the mains The safety device has tripped · · · REMEDY wait plug into the mains socket Contact your local Customer Services The air conditioner works for a short time only · · · the air exhaust hose has a constriction the air exhaust hose is blocked there are bends in the air exhaust hose · · · position the air exhaust hose correctly check there are no obstacles obstructing air discharge eliminate the bends The air conditioner works, but does not cool the room · · · · · window open there are heat sources in the room (burner, lamp, etc) the exhaust hose is detached air filter clogged the air conditioner is not powerful enough for the conditions or size of the room · · · · close the window eliminate the heat source connect the exhaust hose clean or replace the filter Particular odour in the room The air conditioner does not operate for about 3 minutes after restarting it · the air filter is clogged · clean or replace the filter · The safety device has tripped · wait for 3 minutes The alarm light (ALARM) L comes on · The tray under the appliance is full · Empty the tray (see paragraph on end-of-season operations on page 27). SELF-DIAGNOSIS The appliance has a self diagnosis system to identify a number of malfunctions. Error messages are displayed on the appliance display. IF THE APPLIANCE DISPLAYS. . . IF THE APPLIANCE DISPLAYS. . . "Low Temperature" "High Temperature" "Probe Failure" . . . THIS MEANS: room temperature is too low . . . THIS MEANS: room temperature is too high . . . THIS MEANS: contact your local Customer Services. 28 Guarantee/technical specification GUARANTEE AND CUSTOMER SERVICES The conditions of the guarantee and customer service are given on the certificate supplied with your appliance. TECHNICAL CHARACTERISTICS: Power supply voltage Max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PAC A95




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI PAC A95 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.