User manual DELONGHI PAC A140E QUICK GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DELONGHI PAC A140E. We hope that this DELONGHI PAC A140E user guide will be useful to you.


DELONGHI PAC A140E QUICK GUIDE: Download the complete user guide (157 Ko)

Manual abstract: user guide DELONGHI PAC A140EQUICK GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] After transportation, wait at least 1 hour before switching on the unit. You are therefore recommended to place them in the special containers for differentiated waste collection. SAVE THESE INSTRUCTIONS 4 How does your Pinguino work Dur ing the summer, optimum comfort is achieved with a temperature of around 75°F (24 °C) and 50% relative humidity. An air conditioner removes moisture and heat from the room where it is located. One advantage of portable air conditioning units over fitted models is that they can be moved from one room to another in the home or even transferred between different buildings. [. . . ] Carefully hold the panel in the centre and lower to its closed position. During the "water functioning" operation and in particularly silent locations (eg the bedroom) a slight gurgling sound may be heard. IN HIGH HUMIDITY CONDITIONS Water is extracted from the air in the room, this water is also used to cool the appliance. When the humidity is particulary high an excess of water may build up in the internal tank. This can be drained by removing the bung from the drain hose 9 and draining into a suitable receptacle. IMPORTANT: if the room temperature is 90°F (32°C) or over the airconditioner must be operated with water in the tank. seawater or water treated using softening systems that utilize kitchen salt. 8 Turning on and setting the timer ELECTRICAL CONNECTION Before plugging in check that: · the mains supply corresponds to the power supply shown on the rating plate; · the socket and the mains lead correspond to the power requirements of the appliance; · the socket is suited to the plug, otherwise have the socket replaced; · the socket is properly grounded. The manufacturer cannot be held responsible for any damages due to failure in following normal safety procedures. Replacement of the power cable must be carried out by qualified personnel. PROGRAMMED MODE 1) Set the operating times by pushing out the notches on the dial corresponding to the period required (each notch represents 15 mins. ) 2) Press the TIMER key 12 , the signal light 14 will come ON. 3) Make sure that the timer indicates the correct time (see instructions on setting). Funzionamento operating time 11 10 9 4 SETTING THE TIMER The programmer/timer 13 , like all clocks, must be set to the exact time. If for example it is 4. 00 pm. , turn the dial in a clockwise direction (following the direction of the arrow) until the number 4 is lined up with the triangular pointer (the arrows indicates 4:00 P. M. N. B. : To override the programmed operating times, simply press the ON/OFF key 16 (the timer signal lamp 14 will go out) 11 10 9 4 pointer N. B. : Never turn the dial in an anti-clockwise direction!A special safety device will delay the start of air conditionig by approximately 3 to 5 minutes when switching between functions or on initial start up. You may also experience a slight delay between changing from one function to another. 10 Recommendations PURIFICATION FILTER In addition to dust, this purification filter is able to capture even the smallest sized particles and impurities (up to 0. 003 millimetres), such as cigarette smoke. The purification filter should never be used with the dust filter, which is also included with the appliance. If you wish to use the purification filter: Remove the purification filter from the filter housing; Remove the aspiration grill 7 (fig. Anchor the filter to the appliance by attaching the two plastic pieces on the filter to the special supports on the air conditioner (see the illustration below). If the dust filter is sufficient: Remove the purification filter from the filter housing and set it aside. exception is in the case of installation through a hole in the wall or window. In this case, you are recommended to allow a small amount of air to enter through a door or window to guarantee an adequate exchange of air. · Protect the room from direct exposure to the sun's rays by drawing the curtains and/or partially lowering the blinds so as to maximise energy savings. · Make sure there are no heat sources in the room. · Do not use outdoors. do not cover RECOMMENDATIONS Follow these recommendations to achieve maximum efficiency from your air conditioning unit: · Close the doors and windows in the room where the unit is functioning. The only lower the blinds or draw the curtains close doors and windows · Make sure the unit is located on a level floor. [. . . ] close the windows eliminate heat sources fit the hose in the coupling lower the thermostat clean/replace filters three minutes have not passed since it was · turned on windows open a heat source is operating in the room (burner, light, etc. ) or there are a lot of people the air outlet hose has come detached from the coupling thermostat adjusted too high air filters clogged the output of the unit is insufficient for the conditions or size of the room · · · · · · · · · · · The unit works for only a short time · · there is a kink in the exaust hose the exaust hose is blocked · · · · there are too many curves in the outlet tube the fan is blocked · · position the exaust hose correctly check there are no blockages preventing the discharge of air to the outside rearrange the hose correctly contact the Service Centre 14 Technical specification TECHNICAL SPECIFICATION Power supply Max. absorbed power in air conditioning Refrigerating capacity Refrigerant Number of fan speeds Max. Dimensions: · width · height · depth see rating plate " " " 2 370 m3/h RECOMMENDED OPERATING CONDITIONS Room temperature 70°F -90°F (21 ÷ 32°C) 580 mm 785 mm 435 mm 22 21/64" 30 13/32" 17 1/8" This appliance contains substances which, if released into the atmosphere, would damage the ozone layer. Care should therefore be taken not to perforate the refrigerant circuit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PAC A140E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI PAC A140E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.