User manual DELONGHI PAC 600 T

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DELONGHI PAC 600 T. We hope that this DELONGHI PAC 600 T user guide will be useful to you.


DELONGHI PAC 600 T : Download the complete user guide (341 Ko)

You may also download the following manuals related to this product:

   DELONGHI PAC 600 T (339 ko)
   DELONGHI PAC 600 T (335 ko)
   DELONGHI PAC 600 T (335 ko)

Manual abstract: user guide DELONGHI PAC 600 T

Detailed instructions for use are in the User's Guide.

[. . . ] · The appliance should not be installed where the atmosphere may contain combustible gases, oil or sulphur, or near heat sources. · Remember to perform the descaling procedure at the end of each season (see page 13). In areas where the water is particularly hard (rich in minerals), the use of a commercial anti-lime product added to the water is recommended. If this is not possible secure the unit at an angle, do not lie horizontally. · Before transporting the unit drain the condensation collecting-tray and tank. [. . . ] Whenever the plug is disconnected or there is a power failure, the programmer stops (the clock is then "slow") and must be re-set. 9 ENGLISH Selecting functions AIR CONDITIONING FUNCTIONS To turn the unit on in air conditioning mode, proceed as follows: 1. Press the ON/OFF button 11 (the signal light 10 will come on). COOL JET The cool jet mode was conceived to provide the appliance with a greater cooling potential. This is particularly useful when you want to bring the temperature of a very warm room quickly down to a more comfortable level. In this case: Make sure that the tank is full of water (see page 8); Make sure that the function selector switch 19 is in the HIGH position. 2. Rotate the function selector 19 dial anticlockwise: · Place the function selector in the HIGH pos. to operate the unit in air conditioning mode at maximum fan speed, after 3 minutes the signal light 15 will come on ). to operate the unit in air condtioning mode at minimum fan speed (the signal light 21 will come on, and then, after 3 minutes the signal light 16 will come on ). Now set the required temperature by rotating the room thermostat dial 20 . Press the Cool jet button 22 . After reaching the desired temperature, you can release the Cool jet button and reposition the selector switch to the LOW pos. Doing so will make the operation quiter. VENTILATION/FILTRATION Rotate the function selector 19 clockwise. · Press the ON/OFF button 11 (the signal light 10 will come on). · Place the function selector on the "FreshZone" position and choose the desired fan speed (min/max). The signal light 17 or 18 will come on). Note The temperature is not expressed in degrees. We recommend that you turn the thermostat dial to the maximum position. When the desired room temperature has been reached, slowly turn the thermostat in a clockwise direction until it arrives at the position where a click can be heard. The temperature selected in this way will automatically be regulated and maintained, and save energy. When regulating the thermostat, the air conditioning function is temporarily interrupted and the unit continues to operate in fan only mode. In this way, the appliance keeps the air temperature within the room even. PROBLEM WARNING LIGHT 23 indicates that The lighted pilot light the safety device of the pressure switch has switched on. To restore the proper functioning of the appliance, eliminate the possible causes of the problem and press the restore button 6 . The causes may be: 1) The exhaust hose forms a siphon in which condensation water has accumulated: in this case, it is necessary to drain the accumulated out of the machine, outwards (never towards the air conditioner) and eliminate the siphon on the hose. 2) The exhaust hose is obstructed: eliminate the obstacles which obstruct the expulsion of the air to the outside. If, after having repositioned the drainage tube, the machine still does not start up, the problem might be more complicated (ex. : obstructed ventilation fan) and could require the assistance of the Authorised Service Centre. Delay on Start Up 1. A special safety device will delay the start of air conditionig by approximately 3 to 5 minutes when switching between functions or on initial start up. [. . . ] At the end of its working life, delivery the air conditioning unit to a special collection centre. FOR UNITED STATES ONLY: LIMITED WARRANTY We warrant each DE'LONGHI AIR-CONDITIONER to be free from defects in material and workmanship. Our obligation under this warranty is to provide one year parts and labor free from purchase date, with an additional four (4) years on any part of the sealed system consisting of the compressor, evaporator, condenser and factory connected refrigerant tubing. This warranty shall apply only if the AIR-CONDITIONER is used in accordance with the factory directions which accompany it, and on Alternatign Current (AC) circuit. This warranty is in lieu of all other warranties and representations, expressed or implied, and all other obligations or liabilities on our part. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PAC 600 T




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI PAC 600 T will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.