User manual DELONGHI PAC 35

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DELONGHI PAC 35. We hope that this DELONGHI PAC 35 user guide will be useful to you.


DELONGHI PAC 35 : Download the complete user guide (791 Ko)

You may also download the following manuals related to this product:

   DELONGHI PAC 35 (791 ko)
   DELONGHI PAC 35 (791 ko)
   DELONGHI PAC 35 (793 ko)
   DELONGHI PAC 35 (792 ko)
   DELONGHI PAC 35 (791 ko)
   DELONGHI PAC 35 (792 ko)

Manual abstract: user guide DELONGHI PAC 35

Detailed instructions for use are in the User's Guide.

[. . . ] Repeat this operation for the second union. b) Through a small hole (5. 5 x 2. 5 cm. ) in the lower part of the door or window frame. In this case, it is necessary to use the special frame for the connection hose. Frame for hose 5) Detach the condensation hose from its coupling. 6) Disconnect the electrical connector socket by pressing the two retainer tabs. MODELS WITH SPECIAL COUPLINGS If your air-conditioner is fitted with the special rapid-fit coupling, the hose which connects the internal unit to the external unit can also be passed through a round hole in an external wall (diameter: 6 cm. [. . . ] If the humidity is particularly high, it may be necessary to fit the condensation discharge tube (supplied with the machine). In this case, fit the hose to the coupling on the bottom section of the external unit (remove the rubber cap from the coupling). In the event there is still some condensation to be eliminated and the equipment is connected to its electrical feed, the waste pump may turn on spontaneously to get rid of that excess moisture even if the equipment itself has been turned off. The external unit should be protected from the elements (rain, snow, sun, etc. ). Rubber cap The external unit can also be mounted on a wall. In this case, use the special wall-mount brackets. Ring Coupling Washer Castor 20 ELECTRICAL CONNECTIONS Before plugging the unit into the mains, check the following: · the mains voltage must be the same as the voltage shown on the rating plate · the power socket and the mains circuit must be suitable for the power requirements of the unit · the socket must be suitable for the plug; if not, have the socket replaced · the power socket must be properly earthed. The manufacturer declines all responsibility for any damage or injury arising from nonobservance of this safety requirement. This appliance is manufactured in compliance with EEC Directive EN 55014 regarding the suppression of radio interference. · Draw the curtains and/or partially close the blinds to protect the room against direct sunlight. · Ensure that the air intake and discharge vents are not obstructed. · Make sure that there are no sources of heat in the room. FINAL CHECK In order to ensure that your air-conditioner operates with the maximum efficiency, make sure that: · all doors and windows in the room to be airconditioned are closed (except for temporary installation, in which case a window must be left partially open). Close the doors Lower the blinds Close the windows Do not cover YOUR AIR-CONDITIONER IS NOW READY FOR USE. Draw the curtains 21 CONTROL PANEL ON/OFF button ON/OFF pilot light A B C "Alarm" pilot light Timer ON/OFF pilot light Timer notches Thermostat Timer ON/OFF button Selecting fan speed button SETTING THE TIMER The programmer/timer, like all clocks, must be set to the exact time. (16. 00), turn the dial in a clockwise direction (following the direction of the arrow) until the number 16 is lined up with the triangular pointer (the arrows indicates 4:00 P. M. approximately ). PROGRAMMED MODE 1) Release B TIMER button 2) Set the operating times by pushing out the notches on the dial corresponding to the period required (each notch represents 15 mins. ) 3) Check that the timer indicates the correct time (see instructions on setting). Operating time Funzionamento 21 20 19 16 21 20 19 16 arrow pointer Note: Never turn the dial in an anti-clockwise direction!The timer is in effect, an electric clock and works only if the plug is connected to the power supply. Whenever the plug is disconnected or there is a power failure, the programmer stops (the clock is then "slow") and must be re-set. Note: To override the programmed operating times, simply press the ON/OFF key. NON-PROGRAMMED MODE 1) B TIMER button must be pressed 2) Select the desired function as shown in the chart on the following page. Note For technical reasons, the temperature is not expressed in degrees but by a line increasing in thickness. We therefore recommend that when starting up the appliance, the thermostat be turned to maximum (thick green line = maximum cold). When the desired temperature has been reached, turn the thermostat slowly away from the maximum cooling position until the appliance switches off. [. . . ] · Should repair be necessary, contact your nearest authorised Service Centre. · Always remove the plug from the power socket before performing any cleaning or maintenance operations. · Do not move the appliance by pulling the power cord. Filter CLEANING THE AIR FILTER · If the air filter is dirty, air circulation is reduced and the efficiency of the air-conditioner will be diminished. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PAC 35




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI PAC 35 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.