User manual DELONGHI DFH 470M W/W

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DELONGHI DFH 470M W/W. We hope that this DELONGHI DFH 470M W/W user guide will be useful to you.


DELONGHI DFH 470M W/W : Download the complete user guide (671 Ko)

You may also download the following manuals related to this product:

   DELONGHI DFH 470M W/W (681 ko)

Manual abstract: user guide DELONGHI DFH 470M W/W

Detailed instructions for use are in the User's Guide.

[. . . ] To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where openings may become blocked. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. [. . . ] · Press the button "min" until the display shows the minutes for the correct time, then release the button (fig. The flashing of the numbers will continue for a few seconds after the adjustment has finished then stops on the correct time and the clock starts working. (Keep both pushbuttons pressed for more than 3 seconds to move through the hours and minutes in fast mode). To change the time, press pushbuttons "hour" for at least 5 seconds, then proceed as above to modify both hours and minutes. AM AUTO °F O current time room temperature 2) MANUAL FUNCTIONING To operate the heater without timer press the "ON MODE" button. By pressing the "ON MODE" button one or more times, the appliance will select the operating heating power, as follows: AM MAN °F Maximum power AM MAN Medium power °F AM MAN °F Minimum power AM MAN °F Fan only (summer ventilation) AM MAN Off O °F 4 If Maximum power has been selected, adjust the thermostat dial (Fig. 1) to the desired comfort temperature, from 42° and 95° F (5°C to 35°C). By turning the thermostat dial the display will show the selected temperature. In addition, the smaller characters on the right-hand side of the display will indicate the actual room temperature (see figure). MAN selected temperature °F room temperature This heater is equipped with ECC - Electronic Climate Control which automatically monitors and selects the ideal power setting to maintain your chosen temperature. If the selected temperature is higher than the actual room temperature, the appliance will start automatically and rapidly heat the room until it reaches the selected temperature. The unit will automatically maintain the temperature at a constant level, by switching between maximum, medium and minimum power. If the room temperature exceeds the selected temperature level, the appliance will switch off. The appliance will switch on automatically again when the room temperature falls below the selected temperature level. If medium power level has been selected using the "ON MODE" button, the appliance will modulate between medium and minimum power to maintain a selected temperature. 3) ANTIFREEZE FUNCTION Press the "ON MODE" button to select the "P max" power level. When set in this way, the appliance will switch on automatically only if the room temperature falls below 42°F (5°C), to prevent it from freezing, at minimum energy consumption. This function is not guaranteed in the event of black outs, even if lasting just a few seconds. * AM MAN 5 4) PROGRAMMING THE ELECTRONIC TIMER The timer allows you to set 2 programs in a 24 hour period. The yellow timer ON lamp will light up. AM AUTO MAN TIMER ON yellow light °F O / Fig. Set the start time for your program by pressing the "hour button" to set the hour (AM and PM) and the "min" button to set the minutes. To select how long you require the heater to be on, push button " " and push repeatedly until your chosen operating timespan appears. The time periods you are able to choose from are :15', 30', 45', 1hr, 2hr, 4hr (max). AUTO °F AM AUTO AM AUTO O O starting time program A starting time program B operation time 4. To programme the a second time period (program B) press the " AUTO" button twice and proceed as above. (Note: The operating period must be the same as in program A, if the operating time is changed eg. Now set the comfort temperature as previously described by using the thermostat dial. [. . . ] To reset the unit for normal operation, remove the plug from the mains socket for a few minutes, eliminate the cause of overheating (e. g. air intake or outlet grilles obstructed) and then plug the fan heater back in again. Contact your nearest Service Center if the fan heater does not begin normal operation again. 7 LIMITED WARRANTY What DoesThis Warranty Cover?We warrant each appliance to be free from defects in material and workmanship. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI DFH 470M W/W




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI DFH 470M W/W will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.