User manual DEI MERLIN 3000 OWNERS GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DEI MERLIN 3000. We hope that this DEI MERLIN 3000 user guide will be useful to you.


DEI MERLIN 3000 OWNERS GUIDE: Download the complete user guide (316 Ko)

Manual abstract: user guide DEI MERLIN 3000OWNERS GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] ® 3000 Owner's Guide limited lifetime consumer warranty For a period of one calendar year from the date of purchase of this auto-security device, Directed Electronics promises to the ORIGINAL PURCHASER to repair or replace (with a comparable reconditioned model), free of cost, any electronic control module which proves to be defective in workmanship or material under normal use, SO LONG AS THE SYSTEM WAS SOLD, INSTALLED, AND SERVICED BY A PROFESSIONAL AUTO INSTALLER, AND REMAINS IN THE CAR IN WHICH THE SYSTEM WAS ORIGINALLY INSTALLED. If warranty service is necessary you must have a clear copy of your sales receipt containing all of the information shown on the following page. After the first calendar year, from the date of purchase of this auto-security device, Directed Electronics promises to the ORIGINAL PURCHASER to repair or replace (with a comparable reconditioned model) any electronic control module which proves to be defective in workmanship or material under normal use FOR A CHARGE OF $45. 00, SO LONG AS THE SYSTEM WAS SOLD, INSTALLED, AND SERVICED BY A PROFESSIONAL AUTO INSTALLER, AND REMAINS IN THE CAR IN WHICH THE SYSTEM WAS ORIGINALLY INSTALLED. If warranty service is necessary you must have a clear copy of your sales receipt containing all of the information shown on the following page. [. . . ] If system power is lost the siren will sound for five minutes and then reset. 15 © 2 0 0 5 d i re c t e d e l e c t ro n i c s , a l l r i g h t s re s e r v e d diagnostics The microprocessor at the heart of your security system is constantly monitoring all of the switches and sensors that are connected to it. It detects any faulty switches and sensors and prevents them from disabling the entire system. The microprocessor will also record and report any triggers that occurred during your absence. arming diagnostics If the system is armed while an input is active (sensor triggering, etc. ) the unit will chirp once when arming and then once more five seconds later. Refer to the Arm/Disarm Diagnostic Chart for bypass notification details. You are able to see exactly which zone is causing the bypass notification by disarming the system and turning the ignition on. The security system will ignore the input that was active when the system was armed, until the input goes away. For example, if the protective switch is active, you will hear one Bypass Notification chirp (the protective switch is bypassed from the alarm system). Once the protective switch is reset, then 3-seconds later the system resumes normal monitoring of this switch. 16 © 2 0 0 5 d i re c t e d e l e c t ro n i c s , a l l r i g h t s re s e r v e d disarming diagnostics Extra disarm chirps are the Tamper Alert. If four chirps are heard when disarming, the system was triggered in your absence. If four chirps are heard, the LED status indicator will indicate which zone was triggered when the ignition is turned on and will repeat 5-times (refer to the Arm/Disarm Diagnostic Chart and Table of Zones section). Refer to the Multiple Event Total Recall section of this guide. arm/disarm diagnostic chart Action Arm Arm Disarm Disarm No. pause) 1 2 4 Description System armed System armed with zone active and bypassed System disarmed System disarmed with tamper alert System silenced, but still armed, and all zone inputs are inactive and monitored. System silenced, but still armed, and a zone is still active and bypassed. System disarmed with a zone in NPC. High Security 1 Disarm (siren on) High Security 3 Disarm (siren on) Disarm 5 Refer to the table of zones to identify the last zone triggered. © 2 0 0 5 d i re c t e d e l e c t ro n i c s , a l l r i g h t s re s e r v e d 17 table of zones The zone number is the number of LED flashes used by the system to identify a specific input. The standard input assignments are listed below, along with spaces to write in any optional sensors or switches you have had installed. If a Warning Zone response is triggered, the LED will not report it. Zone - Number of LED Flashes 1 2 3 4 5 6 7 Description Tilt Sensor (Built-in Tilt Sensor) Auxiliary sensor 1 input Auxiliary sensor 2 input Normally Closed input (from protective switch) Optional switch input Ignition Input 12 V Power interruptions Dealer-Installed Options anti-code grabbing (ACG) This unit features Anti-Code Grabbing (ACG) with Random Code Encryption. This means the receiver and remotes each use a mathematical formula called an algorithm to change their code each time the remote is used. This technology has been developed to increase the security of the unit. The control unit knows what the next codes should be. 18 © 2 0 0 5 d i re c t e d e l e c t ro n i c s , a l l r i g h t s re s e r v e d high frequency Your system transmits and receives at 433 MHz. This provides a cleaner spectrum with less interference and a more stable signal. rapid resume logic This security system will store its current state to non-volatile memory. If power is lost and then reconnected the system will recall the stored state from memory. [. . . ] Immediately press and release Select each digit by pressing press only. You will hear two chirps. Wait for two siren chirps after a five second pause or five seconds after the last digit has been entered if using less than four digit code number. 6. © 2 0 0 5 d i re c t e d e l e c t ro n i c s , a l l r i g h t s re s e r v e d 29 PIN Code Confirmation Procedure Begin this procedure within 15 seconds of finishing the programming sequence or the new code will not be set. Press and hold for three seconds. LED turns on: New PIN code is learned and programming is complete. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DEI MERLIN 3000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DEI MERLIN 3000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.