User manual D-LINK DFL-260 COMMAND LINE INTERFACE REFERENCE GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual D-LINK DFL-260. We hope that this D-LINK DFL-260 user guide will be useful to you.


D-LINK DFL-260 COMMAND LINE INTERFACE REFERENCE GUIDE: Download the complete user guide (2898 Ko)

You may also download the following manuals related to this product:

   D-LINK DFL-260 BROCHURE (293 ko)
   D-LINK DFL-260 USER MANUAL (4740 ko)
   D-LINK DFL-260 LOG REFERENCE GUIDE (3818 ko)

Manual abstract: user guide D-LINK DFL-260COMMAND LINE INTERFACE REFERENCE GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] Network Security Firewall CLI Reference Guide DFL-210/ 800/1600/ 2500 DFL-260/ 860 Ver. 1. 01 Security Security Network Security Solution http://www. dlink. com CLI Reference Guide DFL-210/260/800/860/1600/2500 NetDefendOS version 2. 12 D-Link Corporation No. http://www. DLink. com Published 2007-04-17 Copyright © 2007 CLI Reference Guide DFL-210/260/800/860/1600/2500 NetDefendOS version 2. 12 Published 2007-04-17 Copyright © 2007 Copyright Notice This publication, including all photographs, illustrations and software, is protected under international copyright laws, with all rights reserved. Neither this manual, nor any of the material contained herein, may be reproduced without written consent of the author. Disclaimer The information in this document is subject to change without notice. [. . . ] DynDnsClientPeanutHull Description Configure the parameters used to connect to the Peanut Hull DynDNS service. Properties Index DNSNames Username Password The index of the object, starting at 1. Configuration Reference Comments Text describing the current object. (Optional) Note If no Index is specified when creating an instance of this type, the object will be placed last in the list and the Index will be equal to the length of the list. 3. 8. 6. LoginClientBigPond Description Configure the parameters used to provide automatic logon to BigPond Internet service. Properties Username Password Comments Username. (Optional) Note This object type does not have am identifier and is identified by the name of the type only. LoginClientTelia Description Configure the parameters used to provide automatic logon to Telia Internet service. Properties Username Password Comments Username. (Optional) Note This object type does not have am identifier and is identified by the name of the type only. DateTime Description Set the date, time and time zone information for this system. Properties TimeZone DSTEnabled DSTOffset DSTStartMonth DSTStartDay DSTEndMonth DSTEndDay TimeSynchronization TimeSyncServerType TimeSyncServer1 TimeSyncServer2 TimeSyncServer3 TimeSyncInterval TimeSyncMaxAdjust TimeSyncGroupIntervalSize Comments Specifies the time zone. (Default: Disable) Type of server for time synchronization, UDPTime or SNTP (Simple Network Time Protocol). (Default: 86400) Maximum time drift in seconds that a server is allowed to adjust. (Default: 600) Interval according to which server responses will be grouped. (Optional) Note This object type does not have am identifier and is identified by the name of the type only. Device Description Global parameters of this device. Properties Name ConfigVersion Comments Name of the device. (Optional) Note This object type does not have am identifier and is identified by the name of the type only. DHCPRelay Description Use a DHCP Relay to dynamically alter the routing table according to relayed DHCP leases. Properties Name Action SourceInterface TargetDHCPServer IPOfferFilter AddRoute AddRouteLocalIP AddRouteGatewayIP RoutingTable MaxRelaysPerInterface Specifies a symbolic name for the relay rule. (Optional) Specifies the IP of the server to send the relayed DHCP packets to. Specifies the span of IP addresses that are allowed to be relayed from the DHCP server. (Default: 1) Enable dynamic adding of routes as leases are added and removed. (Default: No) The IP Address specified here will automatically be published on the interfaces where a route is added. (Optional) Specifies the routing table the clients host route should be added to. (Default: main) Specifies how many relays are allowed per interface, that means, how many DHCP clients are allowed to be relayed through each interface. (Optional) Define what IP the relay should use as gateway IP when passing the requests to the DHCP server. [. . . ] Specifies the host certificate that the security gateway sends to the client. Specifies the root certificate that was used to sign the host certificate. (Default: Yes) If a user has successfully been authenticated, and no traffic has been seen from his IP address for this number of seconds, he/she will automatically be logged out. Configuration Reference SessionTimeout If a user has successfully been authenticated, he/she will automatically be logged out after this many seconds, regardless of if there has been activity from the user or not. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE D-LINK DFL-260




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual D-LINK DFL-260 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.