User manual CULLIGAN SULFUR-CLEER AUTOMATIC WATER FILTER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CULLIGAN SULFUR-CLEER AUTOMATIC WATER FILTER. We hope that this CULLIGAN SULFUR-CLEER AUTOMATIC WATER FILTER user guide will be useful to you.


CULLIGAN SULFUR-CLEER AUTOMATIC WATER FILTER : Download the complete user guide (1442 Ko)

Manual abstract: user guide CULLIGAN SULFUR-CLEER AUTOMATIC WATER FILTER

Detailed instructions for use are in the User's Guide.

[. . . ] Culligan® Sulfur-CleerTM Automatic Water Filter Owners Guide Thank You And Welcome To Your New World Of Better Living With Culligan Water. This system and its installation must comply with state and local regulations. The Culligan® Sulfur-CleerTM water filters have been tested against WQA S-200 for the effective reduction of iron up to 1, 000 gallons and WQA Test Protocol 04-001 and NSF/ANSI Standard 42 for the effective reduction of hydrogen sulfide as verified and substantated by test data. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. For installations in Massachusetts, the Commonwealth of Massachusetts Plumbing Code 248 CMR shall be adhered to. [. . . ] This cycle is usually brine draw / slow rinse for softeners and a settling time for filters. The display will show "br" in the left most digits and the cycle time in the right most digits. Pressing the "Status" key will save the setting and move to the next programming step. · Cycle 3 Time (Fast Rinse/Refill) - This setting is used to set the time in minutes for cycle 3. The display will show "Fr" followed by the cycle time for this step. Pressing the "Status" key will save the setting and move to the next programming step. 9 Programming (cont. ) · Filter Media Life - This setting is available only with flow meter attached. It enables or disables an alert code (CHANGE MEDIA) that indicates the end of life for the filter media. The display will show "LIFE" in the left most characters and toggle between "Y" and "N" in the right most character with the "+" and "-" keys. If "NO" is selected, the alarm is disabled and the `Maximum Capacity' setting will be treated as it normally would by triggering an immediate regen. If "YES" is selected the alert is enabled and will sound when the `Total Flow/Life of Unit' statistic = `Maximum Capacity' setpoint, indicating that it is time to change the filter media. CHANGE MEDIA Pressing the "Status" key will save the setting and move to the next programming step. · Maximum Capacity Set Point - This setting is used to program a value that corresponds to the maximum capacity that can be expected from a unit before it is completely exhausted. If the unit reaches this set point an immediate regeneration will occur with dip#4 is set to delay mode and "IMMED" set in the hidden menu. This setting will only appear if a flow meter is connected to the circuit board. The display will show the "REGEN" icon and "MAXCAP" for two seconds and then display the "REGEN" icon, and the setting numbers to adjust. Pressing the "Status" key will save the setting and move to the next programming step. · Batch Set Point - This setting is used to set the trip point for a regeneration when in flow meter operation. It will only appear if a flow meter is connected to the circuit board. The display will show the "REGEN" icon and "bAtch" for two seconds and then display the "REGEN" icon and the setting numbers to adjust. Pressing the "Status" key will save the setting and move to the next programming step. · Maintenance Interval - This setting is active only when dip #2 is on. It used to trigger a notice indicating that a maintenance inspection for the system should occur, after counting down the programmed number of days. The display will show "MAINT" for two seconds, followed by the value to adjust. After the programmed number of days has counted down, the Maintenance Alert shall appear on the display (MAINT) every 10 seconds, for 2 seconds at a time, and the beeper shall beep every 30 seconds. REGEN REGEN REGEN REGEN MAINT 365 10 · Auxiliary Output #1 "ON" Time - This setting is used to control the "ON" time of the aux1 output which turns on the compressor and vent solenoid. [. . . ] ______ p. m. Regeneration Interval __________ days (Time clock models) Number of people in household Water Analysis Total Hardness _______ (gpg) Total Iron _______ (ppm) Hydrogen Sulfide____________ (ppm) Other 21 Culligan Limited Warranty Culligan® Sulfur-CleerTM Automatic Water Filters You have just purchased one of the finest water conditioners made. As an expression of our confidence in Culligan International Company products, your water conditioner is warranted to the original end-user, when installed in accordance with Culligan specifications, against defects in material and workmanship from the date of original installation, as follows: For a period of ONE YEAR For a period of FIVE YEARS For a period of TEN YEARS The entire conditioner The circuit board The control valve body, excluding internal parts The conditioner tank If a part described above is found defective within the specified period, you should notify your independently operated Culligan dealer and arrange a time during normal business hours for the dealer to inspect the water conditioner on your premises. Any part found defective within the terms of this warranty will be repaired or replaced by the dealer. We are not responsible for damage caused by accident, fire, flood, freezing, Act of God, misuse, misapplication, neglect, oxidizing agents (such as chlorine, ozone, chloramines and other related components), alteration, installation or operation contrary to our printed instructions, or by the use of accessories or components which do not meet Culligan specifications, is not covered by this warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CULLIGAN SULFUR-CLEER AUTOMATIC WATER FILTER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CULLIGAN SULFUR-CLEER AUTOMATIC WATER FILTER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.