User manual CULLIGAN SOFT-MINDER TWIN WATER SOFTENER MODELS FROM 2005 INSTALLATION OPERATION SERVICE GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CULLIGAN SOFT-MINDER TWIN WATER SOFTENER MODELS FROM 2005. We hope that this CULLIGAN SOFT-MINDER TWIN WATER SOFTENER MODELS FROM 2005 user guide will be useful to you.


CULLIGAN SOFT-MINDER TWIN WATER SOFTENER MODELS FROM 2005 INSTALLATION OPERATION SERVICE GUIDE: Download the complete user guide (1228 Ko)

Manual abstract: user guide CULLIGAN SOFT-MINDER TWIN WATER SOFTENER MODELS FROM 2005INSTALLATION OPERATION SERVICE GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] C 12/13/07 DCO # 010262 Owners Guide & Installation Instruction Supplement Soft-Minder® Twin Water Softener Models from 2005 © 2007 Culligan International Company Thank You And welcome to your new world of better living with Culligan water. The Culligan Soft-Minder® Twin Water Softeners are tested and certified by WQA according to WQA S-100 for calcium and magnesium reduction (hardness). For installations in Massachusetts, the Commonwealth of Massachusetts Plumbing Code 248 CMR shall be adhered to. This system and its installation must comply with state and local regulations. If this is your first experience having soft, conditioned water in your home, you'll be amazed at the marvelous difference it makes. [. . . ] Pressing the Extra Cycle button during a Regeneration cycle immediately advances the valve to the next cycle step position and resumes normal step timing. Control Operation During Programming The control only enters the Program Mode with the valve In Service . While in the Program Mode the control continues to operate normally monitoring water usage and keeping all displays up to date. There is no need for battery backup power. Control Operation During A Power Failure During a power failure all control displays and programming are stored for use upon power re-application. The control retains these values for years, if necessary, without loss. The control is inoperative and any calls for Regeneration are delayed. The control, upon power re-application, resumes normal operation from the point that it was interrupted. An inaccurate or flashing Time of Day display indicates that a power outage has occurred. Installation 13 Table 2 - Salt Dosage vs. Timer Settings Unit SM-61 Exchange Capacity @ Salt Dosage Per Regeneration 13, 760 gr @ 3. 3 lb 27, 848 gr @ 9. 3 lb 32, 932 gr @ 15. 0 lb SM-91 21, 193 gr @ 5 lb 42, 890 gr @ 14 lb 50, 732 gr @ 22. 5 lb * Shipped inside control valve Refill Time (Minutes) 4 6 10 4 9 15 2 gpm 3 0. 50 gpm WHITE 1 DLFC Flow 2 gpm Number 3 BLFC Flow 0. 25 gpm 0. 5 gpm* Color RED WHITE* Injector Number 0 1 Gallon Settings The model 9000 valve regenerates with soft water from the other tank, you must subtract the water used for regeneration. If 1000 gallons are available then you must subtract the regeneration water used from the total water available. If there are 1000 gallons available subtract the regeneration water used from total water available. 1000 gallons available ­ 51 gallons used = 949 gallons returning (in regeneration) The meter wheel should be set at 950 gallons. Plug in unit. Sanitizing Procedure A water softener in daily use on a potable water supply generally requires no special attention other than keeping the salt tank filled. Occasionally, however, a unit may require sanitization under one of the following conditions: · · · At start-up time. On private supplies, the appearance of off-tastes and odors, particularly if musty or "rotten egg" (caused by harmless sulfatereducing bacteria). Note: If the water supply contains iron, regenerate the softener before sanitizing to remove iron from the resin. Chlorine bleach and common iron control chemicals may generate toxic fumes when mixed. · If the unit uses culligan Sofner-Gard® or other compounds containing sodium hydrosulfite, sodium bisulfite, or any other reducing agent, disconnect the device feeding the chemical(s) and manually regenerate the unit before sanitizing. Do not use this procedure if the softener salt contains iron control additives. · 14 Culligan Soft-Minder Twin® Softeners 1. Pour directly into the brine chamber 1/3 - 1/2 cup of common household bleach (5. 25% sodium hypochlorite) for each cubic foot of resin in the tank. Do not use lemon scented bleaches, or similar bleaches that contain perfumes. Allow the unit to complete the recharge cycle automatically. If tastes and odors return frequently, even after sanitization, a continuous chlorination system may be needed. Send a water sample to a qualified laboratory for bacterial analysis. Analyzing the System Analyzing the problem involves three basic steps: 1. If steps 1-3 did not reveal the problem, initiate a regeneration cycle and manually cycle the valve to brine draw (#2 position). [. . . ] _______________________________________ Settings Salt Setting _________ lbs. Gallons to signal __________ gallons Number of people in household ____________________________________________________________ Water Analysis Total Hardness _______ (gpg) Total Iron _______ (ppm) Other ___________________________________________________________________________________________________ ________________________________________________________________________________________________________ Records and Data 31 Warranty Culligan Limited Warranty Culligan Soft-Minder® Twin Automatic Water Conditioners You have just purchased one of the finest water conditioners made. As an expression of our confidence in Culligan International Company products, your water conditioner is warranted to the original end-user, when installed in accordance with Culligan specifications, against defects in material and workmanship from the date of original installation, as follows: For a period of ONE YEAR For a period of THREE YEARS For a period of TEN YEARS The entire conditioner Soft-Minder meter The control valve body, excluding internal parts The salt storage container, brine valve and all its component parts, and the fiberglass conditioner tank For the LIFETIME of the original consumer purchaser The Quadra-Hull® conditioner tank and the Cullex® resin If a part described above is found defective within the specified period, you should notify your independently operated Culligan dealer and arrange a time during normal business hours for the dealer to inspect the water conditioner on your premises. Any part found defective within the terms of this warranty will be repaired or replaced by the dealer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CULLIGAN SOFT-MINDER TWIN WATER SOFTENER MODELS FROM 2005




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CULLIGAN SOFT-MINDER TWIN WATER SOFTENER MODELS FROM 2005 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.