User manual CULLIGAN SMART FILTER ARSENIC REDUCTION AUTOMATIC WATER CONDITIONNER 10-INCH SYSTEM

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CULLIGAN SMART FILTER ARSENIC REDUCTION AUTOMATIC WATER CONDITIONNER 10-INCH SYSTEM. We hope that this CULLIGAN SMART FILTER ARSENIC REDUCTION AUTOMATIC WATER CONDITIONNER 10-INCH SYSTEM user guide will be useful to you.


CULLIGAN SMART FILTER ARSENIC REDUCTION AUTOMATIC WATER CONDITIONNER 10-INCH SYSTEM : Download the complete user guide (1415 Ko)

Manual abstract: user guide CULLIGAN SMART FILTER ARSENIC REDUCTION AUTOMATIC WATER CONDITIONNER 10-INCH SYSTEM

Detailed instructions for use are in the User's Guide.

[. . . ] Culligan® Smart Filter Arsenic Reduction Automatic Water Conditioner Owners Guide Thank You And Welcome To Your New World Of Better Living With Culligan Water. The Culligan Smart Filter for Arsenic Reduction Water Conditioners with SoftMinder® Meter sensing device are tested and certified by WQA against NSF/ ANSI Standard 53 for the reduction of total arsenic (pentavalent and trivalent) as verified and substantiated by test data. For installations in Massachusetts, Massachusetts Plumbing Code 248 CMR shall be adhered to. This system and its installation must comply with state and local regulations. If this is your first experience having filtered, conditioned water in your home, you'll be amazed at the marvelous difference it makes. [. . . ] For your nearest Culligan dealer, call (800) 285-5442. Recommended Preventative Maintenance Inspection Schedule The Culligan Gold Series water filter has been designed to provide a good, consistent service life. Routinely inspecting the system may help avoid potentially costly breakdowns related to circumstances outside of the control of the dealer and/or user. The filter is for problem water use and routine maintenance is required. Component Entire System Suggested Inspection Frequency At Start-up, after infrequent use (idle for one week or more) or every 3 - 6 months if on a private water supply. Reason for Maintenance On private supplies, the appearance of off-tastes and odors, particularly if musty or "rotten egg" (caused by harmless sulfate-reducing bacteria) may indicate a need for the system to be sanitized. Build up of sediment, iron and/or other foreign materials (found in some water supplies but not necessarily all) could negatively affect system performance. Replace when arsenic can no longer be removed. Backwash Flow Every 12 months or every time Controller service is performed on the system. Media As needed. 17 Things to Check Before You Call For Service If you unexpectedly experience changes in your water, make these simple checks before calling your Culligan dealer. One of the following conditions may be the reason for your interruption of service. Important If any of the following conditions is found, the water conditioner should be manually recharged according to instructions on page 3 after you have corrected the problem. Power Supply Check your power supply cord. Be certain that the outlet is not controlled by a wall switch which has been turned off. Plug in the transformer then reset conditioner to proper time of day. Blown Fuse Check the house fuse or circuit breaker panel. Replace a blown-out fuse or reset an open circuit breaker. Power Failure Any interruption in your power supply or time changes - such as daylight savings - will disrupt your conditioner's recharge schedule by causing the timer to run off-schedule. Reset timer to proper time of day. Bypass Valves Check to see if they are in the proper position. Cul-Flo-Valv® Bypass, if used, should be in the "Service" position (see page 11). If hand valves are used, see that inlet and outlet valve are opened and that the bypass valve is closed. No Water If you aren't getting any water flow at all, make sure your water supply is working. Open a tap ahead of the conditioner (outside tap) to see if you have any water pressure. If it is in the Service position, put it into the bypass and call your Culligan dealer for service. Increased Usage Guests, family additions, new water-using appliances, etc. , all will result in more water usage and will require more capacity from your conditioner. You can reprogram your recharging schedule by following the directions on pages 4 ­ 6. 18 If the words "PROBLEM FOUND" appear on the main screen, it indicates that there are one or more errors detected. Pushing the "CHECKMARK" button will display the first error present. At the bottom of this list the user can "CLEAR THE ERROR" or "EXIT". Pressing the "CHECKMARK" button on the "CLEAR THE ERROR" message causes the controller to re-check to see if the error condition still exists, if it still exists, the error will remain displayed on the main screen. If the error no longer exists the main menu will return to displaying "SYSTEM OK". error description No Remote RF Signal Motor Position Error Replace Filter Media Call Culligan at xxx-xxx-xxxx Error Codes Reason for error Main board is not receiving a signal from the remote Motor did not move when it should. [. . . ] As an expression of our confidence in Culligan International Company products, your water conditioner is warranted to the original end-user, when installed in accordance with Culligan specifications, against defects in material and workmanship from the date of original installation, as follows: For a period of ONE YEAR For a period of FIVE YEARS The entire conditioner Soft-Minder® meter if so equipped. The Remote Display The Modem For a period of TEN YEARS The GBE Plus circuit board, The control valve body, excluding internal parts. For the LIFETIME of the original consumer purchaser The Quadra-HullTM conditioner tank If a part described above is found defective within the specified period, you should notify your independently operated Culligan dealer and arrange a time during normal business hours for the dealer to inspect the water conditioner on your premises. Any part found defective within the terms of this warranty will be repaired or replaced by the dealer. We are not responsible for damage caused by accident, fire, flood, freezing, Act of God, misuse, misapplication, neglect, oxidizing agents (such as chlorine, ozone, chloramines and other related components), alteration, installation or operation contrary to our printed instructions, or by the use of accessories or components which do not meet Culligan specifications, is not covered by this warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CULLIGAN SMART FILTER ARSENIC REDUCTION AUTOMATIC WATER CONDITIONNER 10-INCH SYSTEM




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CULLIGAN SMART FILTER ARSENIC REDUCTION AUTOMATIC WATER CONDITIONNER 10-INCH SYSTEM will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.