User manual CULLIGAN MARK 89

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CULLIGAN MARK 89. We hope that this CULLIGAN MARK 89 user guide will be useful to you.


CULLIGAN MARK 89 : Download the complete user guide (1213 Ko)

Manual abstract: user guide CULLIGAN MARK 89

Detailed instructions for use are in the User's Guide.

[. . . ] The Good Water Machine® contains replaceable particulate and activated carbon filters. It also includes a replaceable reverse osmosis membrane filter which is critical for the effective reduction of Total Dissolved Solids. The filtered water should be tested periodically to verify that the system is performing properly. Culligan International Company 9399 W. Higgins Road, Suite 1100 Rosemont, Illinois USA 60018 847/430-2800 www. culligan. com Products manufactured and marketed by Culligan International Company (Culligan) and its affiliates are protected by patents issued or pending in the United States and other countries. [. . . ] A softener is strongly recommended for water over 10 gpg. 2 3 6 The exact placement of the components will vary by installation. Although shown beneath a sink, it may be installed in a basement, crawl space, or in an adjacent cabinet. Regardless of where the system is installed, the flow sequence described by (Figure 1) must be observed. The Aqua-Cleer®/Good Water Machine® drinking water system is designed to be mounted near a sink for easy access to cold water and drain lines. Lengths of 1/4-inch and 3/8inch OD plastic tubing will be required to make this installation. A length of Culligan® drain tubing is required to install the air gap siphon break. Evaluate the installation site to determine the easiest path for the plumbing to follow. Take care to make the installation as neat as possible. Aqua-Cleer Faucet Installation Monitor Sensor Drain Cold Water Supply Tubing From Faucet Air Gap - 3/8" Tubing Monitor Post Filter 3/8" Tubing to Faucet Product Port 1/4" Tubing to Faucet Air Gap Feed Line 1/4" Tubing AC-30 Manifold Ball Valve 3/8" Tubing to Faucet Product Port Tank Figure 1 Notice: Install the drain line so that it runs downward with no loops or low spots. Otherwise the unit will overflow at the air gap siphon break built into the faucet, or make irritating gurgling sounds. The concentrate line that leads to the faucet should be installed in a straight vertical path to avoid making a gurgling noise. 7 Servicing Your System Service Schedule When properly maintained, your Good Water Machine will give you years of dependable service. Materials: Pre-flushed activated carbon cartridge and polishing filter cartridge Particle filter Household (5. 25%) bleach - hydrogen peroxide is not recommended Clean 1-gallon plastic container with cap 100-ml graduated cylinder Plastic pan to hold manifold assembly Tubing connector, 3/8" tube x 3/8" tube Flat-blade and #2 Phillips screwdrivers Paper towels Disposable plastic gloves (like those used in the food service industry) 9 Servicing Your System (cont. ) Preparation 1. Fill housing #1 about 2/3 full of the diluted bleach solution from the 1-gallon container. Repeat steps 2 and 3 for housing #2 (activated carbon cartridge) and housing #3 (RO membrane filter). Notice: For RO membrane filters that have a single open-end, pour diluted bleach solution into the center tube. The solution should remain in contact with the RO membrane filter for at least five (5) but no longer than ten (10) minutes. Notice: While waiting for the filters to be sanitized, complete step 4 of the "Sanitizing the Storage Tank and Faucet" section. Using the #2 Phillips screwdriver, loosen the capillary assembly retaining screws, then twist and remove the assembly. Inspect the tubing for plugging and kinks and replace the tubing as needed. Reinstall the capillary assembly, but leave the screws 1/4 turn loose. If the drain flow is not visible with the current tubing connections, install a temporary drain tube in the waste port of the manifold. When water is seen flowing to the drain, carefully loosen the capillary tube assembly retaining screws until the flow to the drain increases. Notice: When the assembly is about 3/16" out of the manifold, the o-ring seal for the capillary tube is bypassed, but there should be no external leaks. [. . . ] Dimensions Filter Assembly 7. 5" W x 3" D x 16. 5" H (20 cm W x 8 cm D x 42 cm H) Storage Tank Standard Medium Large 9" Diameter x 15" H (23 cm Diameter x 38 cm H) 11" Diameter x 15" H (28 cm Diameter x 38 cm H) 15. 5" Diameter x 22" H (40 cm Diameter x 56 cm H) The Good Water Machine models listed above have been tested and certified by WQA according to NSF/ANSI Standard 58 for effective reduction of TDS, barium, cadmium, hexavalent and trivalent chromium, copper, lead, radium 226/228 and selenium as verified and substantiated by test data. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 58. Refer to your Installation and Operating Instructions and printed limited Warranties for more specific product information. To avoid contamination from improper handling and installation, your system should only be installed and serviced by your Culligan Man. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CULLIGAN MARK 89




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CULLIGAN MARK 89 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.