User manual CULLIGAN IRON-CLEER PLUS AUTOMATIC WATER FILTER 10 IRON CLEER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CULLIGAN IRON-CLEER PLUS AUTOMATIC WATER FILTER 10 IRON CLEER. We hope that this CULLIGAN IRON-CLEER PLUS AUTOMATIC WATER FILTER 10 IRON CLEER user guide will be useful to you.


CULLIGAN IRON-CLEER PLUS AUTOMATIC WATER FILTER 10 IRON CLEER : Download the complete user guide (1578 Ko)

Manual abstract: user guide CULLIGAN IRON-CLEER PLUS AUTOMATIC WATER FILTER 10 IRON CLEER

Detailed instructions for use are in the User's Guide.

[. . . ] Culligan® Iron-Cleer® Plus Automatic Water Filter Owners Guide Thank You And Welcome To Your New World Of Better Living With Culligan Water. This system and its installation must comply with state and local regulations. The Culligan® Iron Cleer® water filter has been tested and certified by WQA against WQA S-200 for the effective reduction of iron up to 1, 400 gallons for 10" units and 2, 000 gallons for 12" units. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. For installations in Massachusetts, the Massachusetts Plumbing Code 248 CMR shall be adhered to. [. . . ] After "tor" is shown the display will then show the default of 2:00 AM (or the current programmed time of regeneration if already set). The time can be adjusted in 30 minute increments by pressing the "Up" or "Down" keys. Pressing the "Program" key will save the setting and move to the next programming step. Time Flashing · Cycle 1 Time (Backwash) ­ This setting is used to program the backwash cycle. The display will show the "Backwash" and "Mins" icons and the cycle time in the right most digits. Pressing the "Program" key will save the setting and move to the next programming step. · Cycle 2 Time (Pause) ­ This setting is used to set the time in minutes for cycle 2. This cycle is usually brine draw / slow rinse for softeners and a settling time for filters. The display will show the "BRINE RINSE" and "MINS" icons and the cycle time in the right most digits. Pressing the "Program" key will save the setting and move to the next programming step. · Cycle 3 Time (Fast Rinse) ­ This setting is used to set the time in minutes for cycle 3. The display will show the "FAST RINSE", "/", "REFILL" and "MINS" icons for 4-cycle valves or "FAST RINSE" and "MINS" icons for 5-cycle valves and filters with the cycle time in the right most digits. Pressing the "Program" key will save the setting and move to the next programming step. · Regeneration Interval - This setting is used to set the days between regeneration in time clock mode. It is also active in meter mode if the time clock backup DIP switch # 10 is set to on. The display will show "REGEN" icon and "dAYS" as well as the numbers to change. Pressing the "Program" key will save the setting and move to the next programming step. 8 · Filter Media Life (Change Media) - This setting is used in Filter Mode ONLY with flow meter attached. It enables or disables an alarm code ("CHANGE MEDIA") that indicates the end of life for the filter media. The display will show "LIFE" in the left most characters and toggle between "Y" and "N" in the right most character with the "+" and "-" keys. If "NO" is selected, the alarm is disabled and the `Total Capacity' setting will be treated as it is in Flow Meter Mode (softener). If "YES" is selected, the alarm is enabled and will sound when the `Total Flow/Life of Unit' statistic = `Total Capacity' setpoint, indicating that it is time to change the filter media. Pressing "Program" key will save and advance to the next step. Programming (cont. ) · Total Capacity Set Point (Max Capacity) - This setting is used to program a value that corresponds to the maximum capacity that can be expected from a unit before it is completely exhausted (no reserve). This setting will only appear if a flow meter is connected to the circuit board. The display will show the "REGEN" icon and "MAXCAP" for two seconds and then display the "REGEN" and "GALLONS" or "LITERS" icons (depending on DIPswitch #7 setting) and the setting numbers to adjust. Adjust the value with the "Up" or "Down" keys. When the capacity used equals this total capacity setting with the "Life" feature off, the control will regenerate either immediately or at the time of regen based on the "hidden programming menu" setting. With the "Life" feature on, the control will use this setting to trigger the "Change Media" alarm. [. . . ] If this has not been done, please ask for it, as it is necessary if you contact your dealer. Records and Data Identification Model Name Control Model No. ______ p. m. Regeneration Interval __________ days (Time clock models) Number of people in household Water Analysis Total Hardness _______ (gpg) Total Iron _______ (ppm) Hydrogen Sulfide____________ (ppm) Other 19 Culligan Limited Warranty Culligan® Iron-Cleer® Automatic Water Filters You have just purchased one of the finest water conditioners made. As an expression of our confidence in Culligan International Company products, your water conditioner is warranted to the original end-user, when installed in accordance with Culligan specifications, against defects in material and workmanship from the date of original installation, as follows: For a period of ONE YEAR For a period of FIVE YEARS For a period of TEN YEARS The entire conditioner The AccuSoft® circuit board The control valve body, excluding internal parts The conditioner tank If a part described above is found defective within the specified period, you should notify your independently operated Culligan dealer and arrange a time during normal business hours for the dealer to inspect the water conditioner on your premises. Any part found defective within the terms of this warranty will be repaired or replaced by the dealer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CULLIGAN IRON-CLEER PLUS AUTOMATIC WATER FILTER 10 IRON CLEER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CULLIGAN IRON-CLEER PLUS AUTOMATIC WATER FILTER 10 IRON CLEER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.