User manual CULLIGAN AQUA-CLEER ADVANCED DRINKING WATER SYSTEM 01021609

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CULLIGAN AQUA-CLEER ADVANCED DRINKING WATER SYSTEM 01021609. We hope that this CULLIGAN AQUA-CLEER ADVANCED DRINKING WATER SYSTEM 01021609 user guide will be useful to you.


CULLIGAN AQUA-CLEER ADVANCED DRINKING WATER SYSTEM 01021609 : Download the complete user guide (2897 Ko)

Manual abstract: user guide CULLIGAN AQUA-CLEER ADVANCED DRINKING WATER SYSTEM 01021609

Detailed instructions for use are in the User's Guide.

[. . . ] A 12/04/08 DCO # 010883 Installation, Operation & Service Instructions with Parts List Culligan® Aqua-Cleer® Advanced Drinking Water Systems Models from 2008 For Wisconsin © 2008 Culligan International Company Attention Culligan Customer: Your local independently operated Culligan dealer employs trained service and maintenance personnel who are experienced in the installation, function and repair of Culligan equipment. This publication is written specifically for the purpose of training and guiding these individuals and is intended for their use. We encourage Culligan users to learn about Culligan products, but we believe that product knowledge is best obtained by consulting with your Culligan dealer. Untrained individuals who use this manual assume the risk of any resulting property damage or personal injury. These systems are intended for use on potable water supplies or disinfected water containing cysts. [. . . ] Note: To disconnect tubing from the product water fitting, hold the collet firmly against fitting body and pull the tube from the fitting. Visually inspect for excessive wear and replace the inner body as needed to protect against any leaks. Be sure that all twists are eliminated from the cable. Final Installation 1. Choose one and install it by removing the screw and slipping the handle into place (see figure 11). You are now ready to install the faucet into the base assembly that is mounted on the sink. First guide the tubing into the center of the base assembly and feed them through until the faucet reaches the base. Hold the base securely with your free hand and insert the faucet into the base and turn it clockwise 1/4 turn. Once the faucet is securely attached to the base the installation of the faucet is complete. Next step is to attach the tubing to the RO system and the drain connection according to the normal installation instructions for the RO system. 16 Culligan® Aqua-Cleer® Drinking Water Systems Changing Handle Orientation 1. Listed below is the procedure to change the handle orientation (refer to figure 11): Remove the handle cap and unscrew the handle screw. Unscrew the handle cartridge nut. Remove the handle cartridge and rotate it 180° making sure the notches on the cartridge line-up with the notches on the faucet housing. Reverse the procedure for reassembly. Cleaning the Faucet Wipe the faucet with a soft cloth, avoid abrasive cleansers. Provide Inlet Water Supply A wide variety of plumbing circumstances and choices exist to provide the feed water supply. The first connection in the system is at the prefilter where a 1/4-inch connection is supplied. The supply water plumbing should therefore terminate in a 1/4-inch tube fitting. Copper tubing or galvanized iron pipe is the typical plumbing used in most homes. Piercing Valve A special piercing valve (Figure 12), is available which makes its own hole as it is tightened down. Note: Check with local plumbing codes to verify that piercing valve is allowed. Figure 12 Installation 17 Connecting Aqua-Cleer® System Drains Plumbing codes require that the drain from reverse osmosis drinking water systems be discharged through an air gap siphon break. The discharge from the air gap must be connected to the plumbing system for proper drainage. Incorrect installation may result in overflow of the air gap or excessive noise. If the concentrate water is discharged to an open drain, the air gap may not be necessary. The air gap feature of the Culligan® faucet requires standard 3/8" tubing. Connections to undersink plumbing can be made with a saddle clamp designed to accept the drain tubing from the faucet. Culligan offers a saddle kit, PN 01-0003-29, designed for 1-1/2" undersink drain plumbing (Figure 13). [. . . ] Check air gap operation and the drain tubing for restriction or leaks. If a new membrane was installed, take new product flow measurements and allow more time for rinsing. 8. Instruct the customer (or leave instructions) to discard the first large glass of water removed from the faucet (or drain the tank once if membrane was replaced) before using the water. Thoroughly check for leaks - again. 30 Culligan® Aqua-Cleer® Drinking Water Systems Aqua-Cleer® Estimated Flow Rates - Table 4 Temperature Feed PSI 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 NDP 20. 0 25. 0 30. 0 35. 0 40. 0 45. 0 50. 0 55. 0 60. 0 65. 0 70. 0 75. 0 80. 0 85. 0 90. 0 95. 0 °F TCF 2. 5 2. 0 1. 7 1. 4 1. 3 1. 1 1. 0 0. 9 0. 8 0. 8 0. 7 0. 7 0. 6 0. 6 0. 6 0. 5 35 2. 23 14. 1 17. 7 21. 2 24. 7 28. 3 31. 8 35. 3 38. 9 42. 4 45. 9 49. 5 53. 0 56. 5 60. 1 63. 6 67. 1 40 2. 03 15. 6 19. 4 23. 3 27. 2 31. 1 35. 0 38. 9 42. 8 46. 7 50. 5 54. 4 58. 3 62. 2 66. 1 70. 0 73. 9 45 1. 84 17. 1 21. 4 25. 7 29. 9 34. 2 38. 5 42. 8 47. 1 51. 3 55. 6 59. 9 64. 2 68. 4 72. 7 77. 0 81. 3 50 1. 68 18. 8 23. 5 28. 2 32. 9 37. 7 42. 4 47. 1 51. 8 56. 5 61. 2 65. 9 70. 6 75. 3 80. 0 84. 7 89. 4 55 1. 52 20. 7 25. 9 31. 1 36. 3 41. 4 46. 6 51. 8 57. 0 62. 1 67. 3 72. 5 77. 7 82. 9 88. 0 93. 2 98. 4 60 1. 38 22. 8 28. 5 34. 2 39. 9 45. 6 51. 3 57. 0 62. 7 68. 4 74. 1 79. 8 85. 5 91. 2 96. 9 102. 6 108. 3 65 1. 26 25. 1 31. 3 37. 6 43. 9 50. 2 56. 4 62. 7 69. 0 75. 2 81. 5 87. 8 94. 0 100. 3 106. 6 112. 8 119. 1 70 1. 14 27. 6 34. 5 41. 4 48. 3 55. 2 62. 1 69. 0 75. 9 82. 8 89. 7 96. 6 103. 5 110. 4 117. 3 124. 2 131. 1 75 1. 04 30. 4 37. 9 45. 5 53. 1 60. 7 68. 3 75. 9 83. 5 91. 1 98. 7 106. 3 113. 8 121. 4 129. 0 136. 6 144. 2 80 0. 94 33. 4 41. 8 50. 1 58. 5 66. 8 75. 2 83. 5 91. 9 100. 2 108. 6 116. 9 125. 3 133. 6 142. 0 150. 3 158. 7 85 0. 86 36. 8 45. 9 55. 1 64. 3 73. 5 82. 7 91. 9 101. 1 110. 3 119. 4 128. 6 137. 8 147. 0 156. 2 165. 4 174. 6 PCF Product Flow Rate in milliliters per minute Your measured results are acceptable if within 20% of the figures above. Estimated flow to the drain should average about the same as the 75 column and should be almost double that flow rate if fed with hard water above 10 gpg. Service & Maintenance 31 Troubleshooting Guide If a problem cannot be corrected through use of this Troubleshooting Guide and assistance from the factory is required, please have the following information available: 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CULLIGAN AQUA-CLEER ADVANCED DRINKING WATER SYSTEM 01021609




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CULLIGAN AQUA-CLEER ADVANCED DRINKING WATER SYSTEM 01021609 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.