User manual CUE SENSORCUE-W

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CUE SENSORCUE-W. We hope that this CUE SENSORCUE-W user guide will be useful to you.


CUE SENSORCUE-W : Download the complete user guide (209 Ko)

Manual abstract: user guide CUE SENSORCUE-W

Detailed instructions for use are in the User's Guide.

[. . . ] Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Programming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. 8. Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Connecting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The temperature and daylight sensors must not be covered so that the functionality of sensorCUE-W is ensured. The standard CUEwire is connected via 4-conductor cable, containing the 24 VDC power supply and RS-485 data. sensorCUE-W front view Daylight sensor Temperature sensor User Manual sensorCUE-W www. cuesystem. com Page 5 of 14 3. Connecting The connection of sensorCUE-W is described in the picture below. sensorCUE-W rear view DIP switch for address settings CUEwire connector 1 S1 Pin 1 2 J2 Signal +24 G A+ B- Description Power +24 VDC Ground RS-485 Data + RS-485 Data - Phoenix 4-pin 3. 5 mm 3 4 1 2 3 4 CUEwire connector User Manual sensorCUE-W www. cuesystem. com Page 6 of 14 4. Addressing Each unit connected to the CUEwire bus must have its unique address. These addresses for touchpanels and keyboards are set in configuration and are called , , panel addresses". The ADDRESS of the sensorCUE-W is binary coded by DIP switch located on the rear panel. 126 127 Function ADDRESS bit 0 ADDRESS bit 1 ADDRESS bit 2 ADDRESS bit 3 ADDRESS bit 4 ADDRESS bit 5 ADDRESS bit 6 Not used SW1 ON OFF ON OFF ON OFF ON OFF ON . . . ON ON Address bit's weight 1 2 4 8 16 32 64 Not used SW6 OFF OFF OFF OFF OFF OFF OFF OFF OFF . . . Programming The standard command for reading out the data from sensorCUE-W is: RemoteVariableGet (reference as Word, paneladdress As Byte) as Word The reference allows to identify which measured value should be read while the paneladdress identifies which sensorCUE unit is to answer. The following reference values are supported: · Reference = 0 sensorCUE firmware version · Reference = 1 temperature value · Reference = 2 lighting level value Reference = 0 sensorCUE-W firmware version Response value is in range 0 - 65535 Example: Fw = RemoteVariableGet (0, 34) This command has assigned the firmware version number of sensorCUE-W (with the address 34) to the Fw variable. Reference = 1 temperature value The temperature is measured with a 12-bit resolution sensor. It covers the measuring range from +50 °C to -20 °C The temperature value is encoded into a 16-bit response value according to the following rules: Response value bit weight BIT 15 S 14 S 13 S 12 S 11 S 10 26 9 25 8 24 7 23 6 22 5 21 4 20 3 2-1 2 2-2 1 2-3 0 2-4 S means sign. S=0 for positive and S=1 for negative values. User Manual sensorCUE-W www. cuesystem. com Page 8 of 14 Temperature ­Response data relationship: TEMPERATURE +25. 0625°C +10. 125°C +0. 5°C +0°C -0. 5°C -10. 125°C RESPONSE VALUE (binary) 0000 0001 1001 0001 0000 0000 1010 0010 0000 0000 0000 1000 0000 0000 0000 0000 1111 1111 1111 1000 1111 1111 0101 1110 RESPONSE VALUE (hex) 0191H 00A2H 0008H 0000H FFF8H FF5EH Example: T = RemoteVariableGet (1, 68) This command has assigned the temperature from sensorCUE-W (with the address 68) to the T variable. Reference = 2 the lighting level value The expected response value range is ( 1 - 30000). The lowest values mean the highest lighting levels and the highest values mean dark. The typical expected return values are as follows: For straight full light the return values are below 100 For bright room the return values are about 700-800 For dark room the return values are about 3500-5000 Example: Light = RemoteVariableGet (2, 47) This command has assigned the lighting level from sensorCUE-W (with the address 47) to the Light variable. User Manual sensorCUE-W www. cuesystem. com Page 9 of 14 6. Program module for sensorCUE For easier programming you can use the module sensorCUE. csm. You can find it on the CUE Application CD in folder XPL Drivers and Modules. This module has two functions: Public Function Temperature (PanelAddress As Word, ByRef TemperatureAsText As String) As Integer GetTemperature returns current temperature measured in 1/10 degrees of Celsius as integer value (it allows negative values). The first parameter is the panel address of sensorCUE-W, the second parameter is string, where temperature value will be stored as string ("-20. 0" to "+50. 0") Example: Declarations: Public TemperatureInt As Integer Public TemperatureString As String *10 Program: TemperatureInt = GetTemperature(38, TemperatureString) This command has assigned the temperature from sensorCUE-W (with the address 38) to the TemperatureInt variable. If current temperature is for example +23. 5 °C, in TemperatureInt variable will be value 235. [. . . ] If You have purchased a Site License, You may complete only the number of installations specified in the License Agreement accompanying the Software. Copyright: The Software and software built into CUE hardware ("Firmware") are protected by copyright law and international treaty provisions. You acknowledge that no title to the intellectual property in the Software and Firmware is transferred to You. You further acknowledge that title and full ownership rights to the Software and Firmware will remain the exclusive property of CUE, and You will not acquire any rights to the Software and Firmware except as expressly set forth in this License. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CUE SENSORCUE-W




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CUE SENSORCUE-W will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.