[. . . ] Crestron Isys® TPS-3000 6. 4 Inch Tilt Touchpanel Operations Guide
This document was prepared and written by the Technical Documentation department at:
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON
All brand names, product names and trademarks are the property of their respective owners. ©2005 Crestron Electronics, Inc.
Crestron Isys® TPS-3000
6. 4 Inch Tilt Touchpanel
Contents
6. 4 Inch Tilt Touchpanel: Crestron Isys® TPS-3000 1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Unjoined objects are not interfaced with the system and thus cannot initiate any functions.
Programming with Crestron System Builder
The easiest method of programming, but does not offer as much flexibility as SIMPL Windows.
Crestron System Builder offers automatic programming for such residential and commercial applications as audio distribution, home theater, video conferencing, and lighting. The interface of this tool guides you through a few basic steps for designating rooms and specifying the control system, touchpanels, devices, and functionality. Crestron System Builder then programs the system, including all touchpanel projects and control system logic. Crestron System Builder is fully integrated with Crestron's suite of software development tools, including SIMPL Windows, VT Pro-e, Crestron Database, User IR Database, and User Modules Directory. Crestron System Builder accesses these tools behind the scenes, enabling you to easily create robust systems.
22 · 6. 4 Inch Tilt Touchpanel: Crestron Isys® TPS-3000
Operations Guide DOC. 6076A
Crestron Isys® TPS-3000
SystemBuilder
6. 4 Inch Tilt Touchpanel
For additional details, download SystemBuilder from the Crestron website and examine the extensive help file.
Programming with SIMPL Windows
NOTE: The following assumes that the reader has knowledge of SIMPL Windows. If not, refer to the extensive help information provided with the software. SIMPL Windows is Crestron's software for programming Crestron control systems. It provides a well-designed graphical environment with a number of workspaces (i. e. , windows) in which a programmer can select, configure, program, test, and monitor a Crestron control system. SIMPL Windows offers drag and drop functionality in a familiar Windows® environment. This section describes a sample SIMPL Windows program that includes a TPS-3000 touchpanel. Configuration Manager is where programmers "build" a Crestron control system by selecting hardware from the Device Library. In Configuration Manager, drag the PRO2 from the Control Systems folder of the Device Library and drop it in the upper pane of the System Views. The PRO2 with its associated communication ports is displayed in the System Views upper pane.
PRO2 System View
The System Views lower pane displays the PRO2 system tree. This tree can be expanded to display and configure the communications ports.
Operations Guide DOC. 6076A
6. 4 Inch Tilt Touchpanel: Crestron Isys® TPS-3000 · 23
6. 4 Inch Tilt Touchpanel
Expanded PRO2 System Tree
Crestron Isys® TPS-3000
C2Net-Device Slot in Configuration Manager
In Configuration Manager, drag the TPS-3000 from the touchpanels folder of the Device Library and drop it on the C2Net-Device Slot. The PRO2 system tree displays the touchpanel in Slot 9, with a default Net ID of 03, as shown in the following illustration.
C2Net Device, Slot 9
Setting the Net ID in Device Settings
Double-click the TPS-3000 icon in the upper pane to open the "Device Settings" window. Select the Net ID tab to change the gateway Net ID, as shown in the following figure.
"Device Settings" Window for the TPS-3000
24 · 6. 4 Inch Tilt Touchpanel: Crestron Isys® TPS-3000
Operations Guide DOC. 6076A
Crestron Isys® TPS-3000
6. 4 Inch Tilt Touchpanel
NOTE: This procedure sets the Net ID for the TPS-3000 in the program only. SIMPL Windows automatically changes Net ID values of a device added to a program if a duplicate device or a device with the same Net ID already exists in the program. Always ensure that the hardware and software settings of the Net ID match. For Net ID hardware settings details, refer to "Interface Menu" on page 12.
TPS-3000 Symbol in Programming Manager
Programming Manager is where programmers "program" a Creston control system by assigning signals to symbols. [. . . ] Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number, and return address. Products may be returned for credit, exchange, or service with a CRESTRON Return Merchandise Authorization (RMA) number. Authorized returns must be shipped freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N. J. 07647, or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. [. . . ]