User manual CRESTRON TPS-2000L

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CRESTRON TPS-2000L. We hope that this CRESTRON TPS-2000L user guide will be useful to you.


CRESTRON TPS-2000L : Download the complete user guide (1532 Ko)

Manual abstract: user guide CRESTRON TPS-2000L

Detailed instructions for use are in the User's Guide.

[. . . ] Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mounted Touchpanel Operations Guide This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2003 Crestron Electronics, Inc. Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel Contents 5 Inch Lectern/Wall Mount Touchpanel: TPS-2000L 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] SIMPL Windows is Crestron's software for programming Crestron control systems. It provides a well-designed graphical environment with a number of workspaces (i. e. , windows) in which a programmer can select, configure, program, test, and monitor a Crestron control system. SIMPL Windows offers drag and drop functionality in a familiar Windows® environment. This section describes a sample SIMPL Windows program that includes a TPS-2000L touchpanel. Configuration Manager is where programmers "build" a Crestron control system by selecting hardware from the Device Library. In Configuration Manager, drag the PRO2 from the Control Systems folder of the Device Library and drop it in the upper pane of the System Views. The PRO2 with its associated communication ports is displayed in the System Views upper pane. Operations Guide ­ DOC. 5972A 5 Inch Lectern/Wall Mount Touchpanel: TPS-2000L · 17 5 Inch Lectern/Wall Mount Touchpanel PRO2 System View Crestron Isys TPS-2000L The System Views lower pane displays the PRO2 system tree. This tree can be expanded to display and configure the communications ports. Expanded PRO2 System Tree C2Net-Device Slot in Configuration Manager To incorporate the TPS-2000L touchpanel into the system, drag the TPS-2000 from the Touchpanels | Touchpanels (Cresnet) folder of the Device Library and drop it in the System Views. The PRO2 system tree displays the touchpanel in slot 9 with a default NET ID of 03 as shown in the following illustration. NOTE: The first touchpanel in a system is preset with a NET ID of 03, when its symbol is dragged into the upper pane of System Views. Additional touchpanels are assigned different NET ID numbers as they are added. C2Net Device, Slot 9 Setting the Net ID in Device Settings Double-click the TPS-2000L icon to open the "Device Settings" window. If necessary, select the Net ID tab to change the Net ID, as shown in the following figure. 18 · 5 Inch Lectern/Wall Mount Touchpanel: TPS-2000L Operations Guide ­ DOC. 5972A Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel "Device Settings" Window for the TPS-2000L NOTE: SIMPL Windows automatically changes NET ID values of a device added to a program if a duplicate device or a device with the same default NET ID already exists in the program. Always ensure that the hardware and software settings of the NET ID match. For NET ID hardware settings details, refer to "Interface Menu" on page 8. TPS-2000L Symbol in Programming Manager Programming Manager is where programmers "program" a Creston control system by assigning signals to symbols. The following diagram shows the TPS-2000L symbol in the SIMPL Windows' Programming Manager. Detail View of the TPS-2000L in SIMPL Windows' Programming Manager Digital Analog Serial NOTE: Join numbers are expandable to 4000 digital & analog, 999 serial. Signal Types Signals interconnect the various devices and logic symbols that comprise a SIMPL program. For any given signal, the signal type is determined by its driving source. That is, if the symbol that drives the signal has an analog output, then, by definition, the connecting signal is analog. Operations Guide ­ DOC. 5972A 5 Inch Lectern/Wall Mount Touchpanel: TPS-2000L · 19 5 Inch Lectern/Wall Mount Touchpanel Crestron Isys TPS-2000L In SIMPL Windows, the signal types are color-coded as follows: Digital = Blue Analog = Red Serial = Black Undefined/Other = Green NOTE: "Other" signals are a combination of the three basic types (e. g. many symbols accept either analog or serial signals where the combination is shown as a green signal). The signal type is displayed on the Status Bar when the signal is highlighted. [. . . ] Products may be returned for credit, exchange, or service with a CRESTRON Return Merchandise Authorization (RMA) number. Authorized returns must be shipped freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N. J. , or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a 15% restocking fee, plus shipping costs, on any products returned with an RMA. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON TPS-2000L




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON TPS-2000L will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.