User manual CRESTRON TPS TPMC-CBL-T3 T6 T9

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CRESTRON TPS TPMC-CBL-T3 T6 T9. We hope that this CRESTRON TPS TPMC-CBL-T3 T6 T9 user guide will be useful to you.


CRESTRON TPS TPMC-CBL-T3 T6 T9 : Download the complete user guide (554 Ko)

Manual abstract: user guide CRESTRON TPS TPMC-CBL-T3 T6 T9

Detailed instructions for use are in the User's Guide.

[. . . ] For specific models, refer to "Compatible Touchpanels" on page 2. The Triamese cable is used to connect Cresnet®, CAT5 audio, and CAT5 video wiring from a TPMC-CH-IMC to the touchpanel's NET, VIDEO, and AUDIO ports. The cable is available in 3-, 6-, and 9-foot lengths in either black or white. Supplied with the touchpanel is a TPMC-CH-IMC Interface Module that serves as an interface between the touchpanel, the audio and video sources, and/or the Crestron remote control system (herein referred to as the Cresnet system). [. . . ] If attaching to a TPMC-Series touchpanel, connect the connector labeled VIDEO to either the VIDEO IN 1 port or the VIDEO IN 2 port. Connect Triamese Cable Connectors to TPS-Series Touchpanel CRESNET TRIAMESE CABLE FROM TPMC-CH-IMC VIDEO AUDIO Connect Triamese Cable Connectors to TPMC-Series Touchpanel CRESNET TRIAMESE CABLE FROM TPMC-CH-IMC VIDEO AUDIO NOTE: Since the TPMC touchpanels use an external power supply, the 24 VDC connection is not required when connecting the Triamese cable to the NET port of the touchpanel or the TPMC-CH-IMC. Installation Guide - DOC. 6399 Triamese Cable for TPS/TPMC Panels: TPS/TPMC-CBL-T3/6/9 · 5 Triamese Cable for TPS/TPMC Panels Crestron TPS/TPMC-CBL-T3/6/9 2. As shown in the following diagram, connect the connector labeled VIDEO to the VIDEO (TO PANEL) port (RED), the connector labeled AUDIO to the AUDIO (TO PANEL) port (BLUE), and the connector labeled CRESNET to the NET (TO PANEL) port. Connect Triamese Cable Connectors to TPMC-CH-IMC TRIAMESE CABLE FROM TOUCHPANEL AUDIO VIDEO CRESNET 6 · Triamese Cable for TPS/TPMC Panels: TPS/TPMC-CBL-T3/6/9 Installation Guide - DOC. 6399 Crestron TPS/TPMC-CBL-T3/6/9 Triamese Cable for TPS/TPMC Panels Further Inquiries If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling the Crestron corporate headquarters at 1-888-CRESTRON [1-888-273-7876]. For assistance in your local time zone, refer to the Crestron website (www. crestron. com) for a listing of Crestron worldwide offices. You can also log onto the online help section of the Crestron website to ask questions about Crestron products. First-time users will need to establish a user account to fully benefit from all available features. Future Updates As Crestron improves functions, adds new features, and extends the capabilities of the TPS/TPMC-CBL-T3/6/9, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision. Check the Crestron website periodically for manual update availability and its relevance. Updates are identified as an "Addendum" in the Download column. Installation Guide - DOC. 6399 Triamese Cable for TPS/TPMC Panels: TPS/TPMC-CBL-T3/6/9 · 7 Triamese Cable for TPS/TPMC Panels Crestron TPS/TPMC-CBL-T3/6/9 Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number, and return address. Products may be returned for credit, exchange, or service with a CRESTRON Return Merchandise Authorization (RMA) number. Authorized returns must be shipped freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N. J. , or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a 15% restocking fee, plus shipping costs, on any products returned with an RMA. Return freight charges following repair of items under warranty shall be paid by CRESTRON, shipping by standard ground carrier. In the event repairs are found to be non-warranty, return freight costs shall be paid by the purchaser. 2. 3. CRESTRON Limited Warranty CRESTRON ELECTRONICS, Inc. [. . . ] Any implied warranties that may be imposed by law are limited to the terms of this limited warranty. Trademark Information All brand names, product names, and trademarks are the sole property of their respective owners. Windows95/98/Me/XP and WindowsNT/2000 are trademarks of Microsoft Corporation. 8 · Triamese Cable for TPS/TPMC Panels: TPS/TPMC-CBL-T3/6/9 Installation Guide - DOC. 6399 Crestron TPS/TPMC-CBL-T3/6/9 Triamese Cable for TPS/TPMC Panels This page intentionally left blank. Installation Guide - DOC. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON TPS TPMC-CBL-T3 T6 T9




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON TPS TPMC-CBL-T3 T6 T9 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.