User manual CRESTRON MP2 MP2E
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CRESTRON MP2 MP2E. We hope that this CRESTRON MP2 MP2E user guide will be useful to you.
Manual abstract: user guide CRESTRON MP2 MP2E
Detailed instructions for use are in the User's Guide.
[. . . ] Crestron MP2 & MP2E 2-Series Integrated AV Control System Operations Guide
This document was prepared and written by the Technical Documentation department at:
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON
All brand names, product names and trademarks are the property of their respective owners. ©2006 Crestron Electronics, Inc.
Crestron MP2 & MP2E
2-Series Integrated AV Control System
Contents
2-Series Integrated AV Control System: MP2 & MP2E 1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 6175A
Series-2 Integrated AV Control System: MP2 & MP2E · 21
2-Series Integrated AV Control System
Crestron MP2 & MP2E
NOTE: The SIMPL Windows symbol will allow any valid value. Programming the parametric equalizer through SIMPL Windows may override the Digital Media Tools settings. For example, if the 5-band graphic equalizer mode is specified in Digital Media Tools and the SIMPL Windows program then changes one of the graphic filters, the system reverts to full parametric mode. SIMPL Windows permits any legal change without regard to the effect on the rest of the filters. NOTE: The Mute On/Off button is the "hot" button for muting the system when Real-Time mode is enabled in Digital Media Tools. This feature protects the speakers if, during Real Time mode, unreasonable values for filters and fields are entered in the program. An emergency MUTE button is also provided at the bottom of each screen. The MUTE button on the tool bar and the MUTE selection on the Tools Menu toggle MUTE on and off.
Example Program
An example program for the MP2 & MP2E is available from the Crestron website (http://www. crestron. com/exampleprograms).
22 · 2-Series Integrated AV Control System: MP2 & MP2E
Operations Guide DOC. 6175A
Crestron MP2 & MP2E
2-Series Integrated AV Control System
Uploading and Upgrading
Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features. However, before attempting to upload or upgrade it is necessary to establish communication. While the next section provides an overview for communication, refer to "Establishing Communications with the Control System" in the Crestron 2-Series Control Systems Reference Guide (Doc. If communications cannot be established, refer to "Troubleshooting Communications" in the same guide.
Establishing Communication
Use Crestron Toolbox for communicating with the MP2 & MP2E; refer to the Crestron Toolbox help file for details. With the MP2 the connection to the computer must be a direct serial connection; with the MP2E the connection can be either serial or TCP/IP. Direct Serial Communication NOTE: Required for initial setup of Ethernet parameters.
Direct Serial Communication
SERIAL VIA CRESTRON CABLE STCP-502PC OR EQUIVALENT
PC RUNNING CRESTRON TOOLBOX
MP2 or MP2E
· ·
The COMPUTER port on the MP2 & MP2E connects to the serial port on the PC via a serial cable (Crestron STCP-502PC or equivalent). Use the Address Book in Crestron Toolbox to create an entry using the expected serial communication protocol (RS-232, auto-detect baud rate, no parity, 8 data bits, 1 stop bit, XON/XOFF disabled, RTS/CTS enabled). icon); Display the MP2's or MP2E's "System Info" window (click the communications are confirmed when the device information is displayed.
· TCP/IP Communication
Ethernet Communication (MP2E only)
PC RUNNING CRESTRON TOOLBOX
ETHERNET
MP2E
· ·
Establish direct serial communication between MP2E and PC. Enter the IP address, IP mask and default router of the MP2E via the Crestron Toolbox (Functions | Ethernet Addressing); otherwise enable DHCP. If connecting through a hub or router, use CAT5 straight through cables with 8-pin RJ-45
·
Operations Guide DOC. 6175A
Series-2 Integrated AV Control System: MP2 & MP2E · 23
2-Series Integrated AV Control System
Crestron MP2 & MP2E
connectors. Alternatively, use a CAT5 crossover cable to connect the two LAN ports directly without using a hub or router. · · · Use the Address Book in the Crestron Toolbox to create an entry for the MP2E with the MP2E's TCP/IP communication parameters. · When using the MP2E as a "slave", edit the "master" control system's IP table to include an entry for the MP2E. [. . . ] or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any products returned with an RMA. Return freight charges following repair of items under warranty shall be paid by CRESTRON, shipping by standard ground carrier. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON MP2 MP2E
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON MP2 MP2E will begin.