If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CRESTRON IW CLW-SW1RF 4RF SWS1RF 4RF SLVS1RF. We hope that this CRESTRON IW CLW-SW1RF 4RF SWS1RF 4RF SLVS1RF user guide will be useful to you.
Manual abstract: user guide CRESTRON IW CLW-SW1RF 4RF SWS1RF 4RF SLVS1RF
Detailed instructions for use are in the User's Guide.
[. . . ] For more information, refer to the latest version of the infiNET Switches Operations Guide (Doc. 6397) which is available from the Crestron website (www. crestron. com/manuals). In the absence of control system communications, the switch can still be used to control the attached load. The CLW-SWS1RF (-SWS1RF) and CLW-SWS4RF (-SWS4RF) are similar to the -SW1RF and -SW4RF (respectively) with the added capability of working with a slave unit (CLW-SLVS1RF) in a multi-switch / single circuit application. [. . . ] When combining controls in a wallbox, remove inner side sections prior to wiring (refer to the following figure).
Inner Sections of Multiganged Switches (CLW-SW4RF Shown)
REMOVE INNER SECTIONS
No Derating Necessary
VA ratings are for input power to the transformer. If you do not know the input power requirement of the transformer, use the bulb's wattage rating to determine proper rating.
Derating Information for Fluorescent/HID Applications
Part Number -SW1RF/ -SW4RF -SWS1RF/ -SWS4RF -SLVS1RF No Side Removed 8A 8A One Side Removed 5. 5A 5. 5A No Derating Necessary Two Sides Removed 4. 5A 4. 5A
Derating Information for Ceiling Fans
Part Number -SW1RF/ -SW4RF -SWS1RF/ -SWS4RF
RUN SET OFF RUN SET OFF
No Side Removed 3A 3A
One Side Removed 3A 3A
Two Sides Removed 3A 3A
-SLVS1RF
No Derating Necessary
2.
To remove a side section, bend the side section back and forth with a pair of pliers until the section breaks off from the mounting plate. Use a file or sandpaper to remove any excess metal.
DO NOT REMOVE OUTER SECTIONS
The load capacity must also be derated. The following charts provide derating information for various applications.
4 · infiNETTM Wall Box Switch : CLW-SW1/4RF, SWS1/4RF, & SLVS1RF
Installation Guide - DOC. 6293A
infiNETTM SWITCHES
3.
Installation
WARNING: Turn off power at the circuit breaker. Installing with power on can result in serious personal injury and damage to the device. NOTE: The -SW1RF, -SW4RF, -SWS1RF, and -SWS4RF require a neutral wire for operation. If no neutral is present, contact a licensed electrician for installation. NOTE: The -SWS1RF and -SWS4RF must be installed in the same wallbox that contains the connections to the load. NOTE: New installations should be checked for short circuits prior to installing the -SW1RF, -SW4RF, -SWS1RF, -SWS4RF, or -SLVS1RF. NOTE: Since the -SWS1RF or -SWS4RF is installed without a -SLVS1RF, the BLUE lead (Slave) should be capped. Other Wiring For another scenario that may be encountered during installation, refer to Figure 2 on page 8. 6293A
infiNETTM Wall Box Switch: CLW-SW1/4RF, SWS1/4RF, & SLVS1RF · 5
infiNETTM SWITCHES Testing
NOTE: The device may be warm to the touch during operation. Test the installation by setting the switch's mode selection switch (shown in the following diagrams) to the "RUN" position and perform either of the following steps (depending on the switch model).
Parts of CLW-SW1RF, -SWS1RF
For detailed operating instructions, refer to the latest revision of the infiNET Switches Operations Guide (Doc. 6397) which is available from the Crestron website.
Testing a -SLVS1RF
Tap the top of the button to turn on the load. It will emulate the RUN mode of the -SWS1RF (even if connected to a -SWS4RF) unless the mode selection switch of the master is set to "OFF". For more information, refer to the latest version of the infiNET Switches Operations Guide (Doc. 6397) which is available from the Crestron website.
Button
RUN
SET
OFF
Mode Selection Switch
Parts of CLW-SW4RF, -SWS4RF
Button 1 Button 3
RUN SET OFF
Button 2 Button 4 Mode Selection Switch
Testing a -SW1RF and -SWS1RF
With the mode selection switch in the "RUN" position, tap the top of the button to turn on the load. For detailed operating instructions, refer to the latest revision of the infiNET Switches Operations Guide (Doc. 6397) which is available from the Crestron website.
Testing a -SW4RF and -SWS4RF
With the mode selection switch in the "RUN" position, tap the Button 1 to turn on the load. Tap Button 1 again to turn off the load.
6 · infiNETTM Wall Box Switch : CLW-SW1/4RF, SWS1/4RF, & SLVS1RF
Installation Guide - DOC. 6293A
infiNETTM SWITCHES Problem Solving
Troubleshooting
The table after this paragraph provides corrective action for possible trouble situations. [. . . ] This warranty statement supercedes all previous warranties.
Trademark Information All brand names, product names, and trademarks are the sole property of their respective owners. Windows95/98/Me/XP and WindowsNT/2000 are trademarks of Microsoft Corporation.
Further Inquiries
If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling the Crestron corporate headquarters at 1-888-CRESTRON [1-888-273-7876]. For assistance in your local time zone, refer to the Crestron website (www. crestron. com) for a listing of Crestron worldwide offices. You can also log onto the online help section of the Crestron website to ask questions about Crestron products. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON IW CLW-SW1RF 4RF SWS1RF 4RF SLVS1RF
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON IW CLW-SW1RF 4RF SWS1RF 4RF SLVS1RF will begin.