User manual CRESTRON IW CLW-DIM1RF 4RF DIMS1RF 4RF SLVD1RF

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CRESTRON IW CLW-DIM1RF 4RF DIMS1RF 4RF SLVD1RF. We hope that this CRESTRON IW CLW-DIM1RF 4RF DIMS1RF 4RF SLVD1RF user guide will be useful to you.


CRESTRON IW CLW-DIM1RF 4RF DIMS1RF 4RF SLVD1RF : Download the complete user guide (735 Ko)

Manual abstract: user guide CRESTRON IW CLW-DIM1RF 4RF DIMS1RF 4RF SLVD1RF

Detailed instructions for use are in the User's Guide.

[. . . ] The range is dependent on construction of the building, obstructions, and RF interference from other devices. The location of the dimmer is an important factor in determining RF performance. Adding more infiNET devices or repeaters to the network effectively increases the range, strength, and reliability of the network. The -DIM1RF and -DIM4RF feature a three-position mode selection switch. [. . . ] For a smooth appearance, one-piece multigang faceplates (not supplied) can be installed. When combining controls in a wallbox, remove inner side sections prior to wiring as shown in the following diagram. VA ratings are for input power to the transformer. If you do not know the input power requirement of the transformer, use the bulb's wattage rating to determine proper rating. 2. To remove a side section, bend the side section back and forth with a pair of pliers until the section breaks off from the mounting plate. Use a file or sandpaper to remove any excess metal. 4 · infiNETTM Wall Box Dimmer : CLW-DIM1/4RF, DIMS1/4RF, & SLVD1RF Installation Guide ­ DOC. 6292A infiNETTM DIMMERS 3. Installation WARNING: Turn off power at the circuit breaker. Installing with power on can result in serious personal injury and damage to the device. NOTE: The -DIM1RF, -DIM4RF, -DIMS1RF, -DIMS4RF, and -SLVD1RF require a neutral wire in the wallbox for operation. If no neutral is present, contact a licensed electrician for installation or refer to the alternative wiring diagrams described in "Appendix: Wiring Diagrams" on page 8. NOTE: The -DIMS1RF and -DIMS4RF must be installed in the same wallbox that contains the connections to the load. NOTE: New installations should be checked for short circuits prior to installing an infiNET dimmer. NOTE: Since the -DIMS1RF or -DIMS4RF is installed without a -SLVD1RF, the BLUE lead (Slave) should be capped. Alternative Wiring For situations where a neutral is not present or other scenarios that may be encountered during installation, refer to the "Stand-Alone Installations" section of "Appendix: Wiring Diagrams" on page 8. 4. 6292A infiNETTM Wall Box Dimmer: CLW-DIM1/4RF, DIMS1/4RF, & SLVD1RF · 5 infiNETTM DIMMERS Testing a -SLVD1RF Testing NOTE: The device may be warm to the touch during operation. Test the installation by setting the dimmer's mode selection switch (shown in the following diagrams) to the "RUN" position and perform either of the following steps (depending on the dimmer model). Parts of CLW-DIM1RF and -DIMS1RF Tap the top of the button to turn on the load. It will emulate the RUN mode of the -DIMS1RF (even if connected to a -DIMS4RF) unless the mode selection switch of the master is set to "OFF". For more information, refer to the latest version of the infiNET Dimmers Operations Guide (Doc. 6396) which is available from the Crestron website. Button RUN SET OFF Mode Selection Switch Parts of CLW-DIM4RF, -DIMS4RF Button 1 Button 3 RUN SET OFF Button 2 Button 4 Mode Selection Switch Testing a -DIM1RF or-DIMS1RF With the mode selection switch in the "RUN" position, tap the top of the button to turn on the load. For detailed operating instructions, refer to the latest revision of the infiNET Dimmers Operations Guide (Doc. 6396) which is available from the Crestron website. Testing a -DIM4RF or -DIMS4RF With the mode selection switch in the "RUN" position, tap the Button 1 to turn on the load. For detailed operating instructions, refer to the latest revision of the infiNET Dimmers Operations Guide (Doc. 6396) which is available from the Crestron website. 6 · infiNETTM Wall Box Dimmer : CLW-DIM1/4RF, DIMS1/4RF, & SLVD1RF Installation Guide ­ DOC. 6292A infiNETTM DIMMERS Problem Solving Troubleshooting The table after this paragraph provides corrective action for possible trouble situations. [. . . ] Updates are identified as an "Addendum" in the Download column. Installation Guide ­ DOC. 6292A infiNETTM Wall Box Dimmer: CLW-DIM1/4RF, DIMS1/4RF, & SLVD1RF · 7 infiNETTM DIMMERS Appendix: Wiring Diagrams Following are wiring diagrams for circuits that may be found when installing infiNET dimmers: Stand-Alone Installations Figure 1: Wiring a CLW-DIM(S)XRF (CLW-DIMS1RF shown) · Since a -DIMSXRF is installed without a slave, the blue lead of the -DIMS1/4RF must be capped. If a neutral is not present in the wallbox, the wiring shown in the following diagram can be used. Figure 2: Alternative Wiring of -DIM1RF, -DIMS1RF, -DIM4RF, and -DIMS4RF Where Neutral is Not Present (Load-Fed Switch Loop) In the above configuration: · · · · · The white wire from the DIMSXRF to the load is coded HOT. Since a -DIMSXRF is installed without a slave, the blue lead of the -DIMS1/4RF must be capped. Circuits with small magnetic low-voltage loads may not work. 8 · infiNETTM Wall Box Dimmer : CLW-DIM1/4RF, DIMS1/4RF, & SLVD1RF Installation Guide ­ DOC. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON IW CLW-DIM1RF 4RF DIMS1RF 4RF SLVD1RF




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON IW CLW-DIM1RF 4RF DIMS1RF 4RF SLVD1RF will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.