User manual CRESTRON IW CLSI-C6 CLSI-C6M

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CRESTRON IW CLSI-C6 CLSI-C6M. We hope that this CRESTRON IW CLSI-C6 CLSI-C6M user guide will be useful to you.


CRESTRON IW CLSI-C6 CLSI-C6M : Download the complete user guide (321 Ko)

Manual abstract: user guide CRESTRON IW CLSI-C6 CLSI-C6M

Detailed instructions for use are in the User's Guide.

[. . . ] 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888. CRESTRON Fax: 201. 767. 7576 www. crestron. com 1. 2. Firmware Cooling Requirement Environmental Temperature Humidity Overall Dimensions: Height Width Depth Weight 22. 8 oz (646. 37 g) The latest versions can be obtained from the Crestron website. Consult the latest Crestron Product Catalog for a complete list of 2-Series control systems. NOTE: Crestron software and any files on the website are for Authorized Crestron dealers and Crestron Authorized Independent Programmers (CAIP) only. New users may be required to register to obtain access to certain areas of the site (including the FTP site). Installation Guide ­ DOC. [. . . ] Make certain that power is turned off, and ensure that there is at least 12 inches of open space above and below the electrical box location to permit heat dissipation. 2. Installation WARNING: Turn off power at the distribution panel circuit breaker. Installing with power on can result in serious personal injury and damage to the device. CAUTION: To reduce the risk of overheating and possible damage to other equipment, do not install to control a receptacle or a motor-operated appliance. 3. Remove the control panel overlay from the unit (it lifts off ­ is held in place by small tabs) to reveal the upper mounting screw holes. All wires to be inserted in the screw terminals should be stripped 7/16-inch, and screws should be tightened to between 8 and 10 in. -lbs. The maximum wire size is 12 AWG (3 mm²). Installation Guide ­ DOC. 6413A 4. 2 · iLuxTM Lighting Systems: CLSI-C6 & CLSI-C6M iLuxTM Lighting Systems 5. Connect each load wire to the corresponding LOAD terminals on the unit, connect the power line hot wire from the circuit breaker to the HOT terminal on the unit, connect all neutral wires to the NEUTRAL terminal on the unit, and connect all ground wires to the (ground) terminal on the unit. If Cresnet cabling is part of the installation, attach the supplied terminal block connector(s) to the Cresnet cable(s) and plug into the appropriate port(s) on the unit. Make certain that there is a minimum 1/4-inch (0. 6 cm) separation between the Class 2 Cresnet wiring and the Class 1 AC wiring. Carefully tuck all wires into the wallbox and fasten the unit to the wallbox using the four 7/8-inch Phillips screws supplied. Reattach the control panel overlay to the front panel by inserting the four tabs into the slots provided, and install the hinged front cover assembly by lining it up at the top and pressing the bottom edge until it snaps into position. 8. 6. Distribution Panel HOT 10A or 13A Circuit Breaker A/R LOAD 3 LOAD 2 LOAD 1 LOAD 4 LOAD 5 LOAD 6 NEUTRAL Power up and Testing The following illustration shows the front panel of the unit and the controls used during installation. Front Panel Controls and Indicators LED Bargraphs Two-Digit Display Verify the basic installation and wiring connections as follows: 1. Press the Lights button to enable manual light control, and press the right side and the left side of each of the function buttons to increase and decrease the lighting level of those loads. Verify that the intended loads and corresponding LED bargraphs respond appropriately. The loads will ramp down to off while the two-digit display counts down to off (blank). Two seconds after all lights have turned off, the unit's master air-gap relay opens making it safe to service the lighting installations. 1 2 3 4 5 6 Min Sec Lights Shades Save Cancel ^ 2. Scene 1 Scene 2 Scene 3 Scene 4 Scene 5 Scene 6 Function Buttons Installation Guide ­ DOC. 6413A ^ ^ ^ ON OFF iLuxTM Lighting Systems: CLSI-C6 & CLSI-C6M · 3 iLuxTM Lighting Systems Problem Solving Troubleshooting The table after this paragraph provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. CLSI-C6/C6M Installation Troubleshooting TROUBLE Unit does not function. CORRECTIVE ACTION Verify that the unit is properly connected to the power line and that the circuit breaker is closed. Verify that the loads are operational and that they are connected to the iLux unit. 2. Return and Warranty Policies Merchandise Returns / Repair Service 1. [. . . ] This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if any. CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended, or if it has been subjected to misuse, accidental damage, modification, or improper installation procedures. Furthermore, this warranty does not cover any product that has had the serial number altered, defaced, or removed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON IW CLSI-C6 CLSI-C6M




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON IW CLSI-C6 CLSI-C6M will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.