User manual CRESTRON IW CLS-C6 CLS-C6M

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CRESTRON IW CLS-C6 CLS-C6M. We hope that this CRESTRON IW CLS-C6 CLS-C6M user guide will be useful to you.


CRESTRON IW CLS-C6 CLS-C6M : Download the complete user guide (622 Ko)

Manual abstract: user guide CRESTRON IW CLS-C6 CLS-C6M

Detailed instructions for use are in the User's Guide.

[. . . ] Consult the latest Crestron Product Catalog for a complete list of 2-Series control systems. 1. NOTE: Crestron software and any files on the website are for Authorized Crestron dealers and Crestron Authorized Independent Programmers (CAIP) only. New users may be required to register to obtain access to certain areas of the site (including the FTP site) *Other load types can be controlled via optional interface modules. Installation Guide ­ DOC. 6394A (2013406) 11. 06 Specifications subject to change without notice. iLuxTM Lighting Systems Physical Description The following illustration shows the overall dimensions for the CLS-C6 and CLS-C6M. CLS-C6M Overall Dimensions Installation WARNING: Turn off power at the distribution panel circuit breaker. [. . . ] Then, use the following procedure to install the iLux unit (CLS-C6M is shown in the illustrations). Feed the wires (power line from the distribution panel, load wires, plus any required Cresnet cables) through the holes in the wallbox. Then install the box in the wall. · · · 2. Hold the rear of the CLS-C6M unit and remove the front panel and cover assembly by carefully pulling out and up from the bottom edge. Installation Guide ­ DOC. 6394A 2 · iLuxTM Lighting Systems: CLS-C6 & CLS-C6M iLuxTM Lighting Systems 3. Remove the control panel overlay from the unit (it lifts off ­ is held in place by small tabs) to reveal the upper mounting screw holes. All wires to be inserted in the screw terminals should be stripped 7/16-inch, and screws should be tightened to between 8 and 10 in. -lbs. Connect each load wire to the corresponding LOAD terminals on the unit, connect the power line hot wire from the circuit breaker to the HOT terminal on the unit, connect all neutral wires to the NEUTRAL terminal on the unit, and connect all ground wires to the (ground) terminal on the unit. If Cresnet cabling is part of the installation, attach the supplied terminal block connector(s) to the Cresnet cable(s) and plug into the appropriate port(s) on the unit. Make certain that there is a minimum 1/4-inch separation between the Class 2 Cresnet wiring and the Class 1 AC wiring. Carefully tuck all wires into the wallbox and fasten the unit to the wallbox using the four 7/8-inch Phillips screws supplied. Reattach the control panel overlay to the front panel by inserting the four tabs into the slots provided, and install the hinged front cover assembly by lining it up at the top and pressing the bottom edge until it snaps into position. 4. 7. 5. 8. Power up and Testing The following illustration shows the front panel of the unit and the controls used during installation. Front Panel Controls and Indicators Verify the basic installation and wiring connections as follows: 1. Press the Lights button to enable manual light control, and press the right side and the left side of each of the function buttons to increase and decrease the lighting level of those loads. Verify that the intended loads and corresponding LED bargraphs respond appropriately. The loads will ramp down to off while the two-digit display counts down to off (blank). Two seconds after all lights have turned off, the unit's master air-gap relay opens making it safe to service the lighting installations. 2. Installation Guide ­ DOC. 6394A iLuxTM Lighting Systems: CLS-C6 & CLS-C6M · 3 iLuxTM Lighting Systems Problem Solving Troubleshooting The table after this paragraph provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. CLS-C6/C6M Installation Troubleshooting TROUBLE Unit does not function. CORRECTIVE ACTION Verify that the unit is properly connected to the power line and that the circuit breaker is closed. Verify that the loads are operational and that they are connected to the iLux unit. 2. Return and Warranty Policies Merchandise Returns / Repair Service 1. [. . . ] warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three (3) years from the date of purchase from CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and overlay components are covered for 90 days; batteries and incandescent lamps are not covered. This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if any. CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended, or if it has been subjected to misuse, accidental damage, modification, or improper installation procedures. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON IW CLS-C6 CLS-C6M




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON IW CLS-C6 CLS-C6M will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.