User manual CRESTRON IO FT-PWR

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CRESTRON IO FT-PWR. We hope that this CRESTRON IO FT-PWR user guide will be useful to you.


CRESTRON IO FT-PWR : Download the complete user guide (1059 Ko)

Manual abstract: user guide CRESTRON IO FT-PWR

Detailed instructions for use are in the User's Guide.

[. . . ] 7 Hardware Hookup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Problem Solving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 6480 Crestron FT-PWR-B & FT-PWR-BALUM FlipTop Power Center Setup Installation There are two steps to installing the FT-PWR-B and FT-PWR-BALUM. Cable Management Kit The FT-PWR-B and FT-PWR-BALUM are shipped with a separate cable management kit for organizing cables fed into the power center. Tools required · · Phillips screwdriver Appropriate carpentry tools for cutout Parts Supplied for Cable Management Kit PART DESCRIPTION Cable Support Plate Bushing 0. 55 inch (1. 40cm) ID, 0. 80 inch (2. 03 cm) OD Bushing 0. 39 inch (0. 99 cm) ID, 0. 64 inch (1. 63 cm) OD Bushing 0. 31 inch (0. 79 cm) ID, 0. 50 inch (1. 27 cm) OD Screw 04-40, 0. 25 inch (0. 64 cm) L QUANTITY 1 2 2 4 4 The cable support plate should be installed before mounting the FT-PWR-B or FT-PWR-BALUM to a surface. Place bushings on the cables you wish to install in the power center (eight bushings supplied). Thread the cables through the cable support plate slots appropriate to the size of the cable and the bushing you attached in the previous step. Attach the cable support plate using the four 4-40 x ¼ LG screws. If desired, any installed cables can be secured to the bottom bar with tie wraps (not supplied). Operations & Installation Guide ­ DOC. 6480 FlipTop Power Center: FT-PWR-B & FT-PWR-BALUM · 7 FlipTop Power Center Crestron FT-PWR-B & FT-PWR-BALUM Cable Plate Installation Bushings Cable Support Plate (4) 4-40 x 1/4 LG Black Screws Cables Loops Through the Cable Support Plate Cables Passed Through Cable Support Plate Excess Cable Loops Optional Cables NOTE: Ensure that any cables you install have sufficient clearance to enable smooth movement. Mounting to Surface The FT-PWR-B and FT-PWR-BALUM are designed to mount in a horizontal surface, such as a desk top, lectern, or podium. The following diagram illustrates the required opening size to accommodate the FT-PWR-B and FT-PWR-BALUM. Use the supplied template to make the cutout. 8 · FlipTop Power Center FT-PWR-B & FT-PWR-BALUM Operations & Installation Guide ­ DOC. 6480 Crestron FT-PWR-B & FT-PWR-BALUM FlipTop Power Center Cutout Dimensions for FT-PWR-B and FT-PWR-BALUM 6. 38 in (16. 21 cm) 5. 31 in (13. 49 cm) Radius . 125 in (0. 32 cm) Max NOTE: Be sure to feed the attached power cord through the mounting hole before inserting the FT-PWR-B or FT-PWR-BALUM. Mounting Parts Supplied PART DESCRIPTION Screw #6-32, 3/16" L, Pan Head, Phillips Screw #10-32, 2" L, Pan Head, Phillips Mounting Bracket QUANTITY 8 4 2 1. Install the eight supplied #6-32 screws, but do not tighten (four on the front side and four on the rear side). Position the FT-PWR-B or FT-PWR-BALUM in the mounting hole. 2. Operations & Installation Guide ­ DOC. 6480 FlipTop Power Center: FT-PWR-B & FT-PWR-BALUM · 9 FlipTop Power Center Crestron FT-PWR-B & FT-PWR-BALUM Mounting Bracket Screw Locations #6-32 Screws #6-32 Screws Surface Cutout 3. Thread a small portion of the two-inch long #10-32 screws into the mounting brackets (two screws per bracket). Slide the mounting brackets over the #6-32 screws and tighten the #6-32 screws. 4. Mounting Bracket Installation 5. Turn the four #10 screws equally until they contact the underside of the mounting surface enough to secure the unit. DO NOT OVER TIGHTEN. CAUTION: Do not over-tighten the #10 screws as this may damage the surface and/or the unit. 10 · FlipTop Power Center FT-PWR-B & FT-PWR-BALUM Operations & Installation Guide ­ DOC. 6480 Crestron FT-PWR-B & FT-PWR-BALUM Mounting Brackets Installed FlipTop Power Center FOUR #10-32 2"L SCREWS 7. 210 in (18. 31 cm) EIGHT #6-32 3/16"L SCREWS TWO MOUNTING BRACKETS Hardware Hookup Hookup consists of simply plugging the line cord into an appropriate outlet. NOTE: To prevent overheating, do not operate this product in an area that exceeds the environmental temperature range listed in the specifications table. Consideration must be given if installed inside a closed desk or in a closed podium since the operating ambient temperature of these environments may be greater than the room ambient. Contact with thermal insulating materials should be avoided on all sides of the unit. NOTE: The maximum continuous current from equipment under any external load conditions shall not exceed a current limit that is suitable for the minimum wire gauge used in interconnecting cables. The ratings on the connecting unit's supply input should be considered to prevent overloading the wiring. Operations & Installation Guide ­ DOC. [. . . ] CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty. Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or implied, nor authorizes any other party to offer any warranty, including any implied warranties of merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are limited to the terms of this limited warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON IO FT-PWR




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON IO FT-PWR will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.