User manual CRESTRON CLW-DIM CLW-DIMS CLW-SLVD

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CRESTRON CLW-DIM CLW-DIMS CLW-SLVD. We hope that this CRESTRON CLW-DIM CLW-DIMS CLW-SLVD user guide will be useful to you.


CRESTRON CLW-DIM CLW-DIMS CLW-SLVD : Download the complete user guide (657 Ko)

Manual abstract: user guide CRESTRON CLW-DIM CLW-DIMS CLW-SLVD

Detailed instructions for use are in the User's Guide.

[. . . ] The CLW-SLVD (-SLVD) is a slave unit that when used in conjunction with the -DIMS acts as an additional dimmer control point in a multi-dimmer / single circuit application. It does not connect to a Cresnet system and cannot be used without a -DIMS. The -SLVD does not have a mode selection switch and is not programmable. Each dimmer can be covered with a decorative faceplate (not supplied). Specifications Following are specifications for the -DIM, -DIMS, and -SLVD. CLW-DIM, CLW-DIMS, & CLS-SLVD Specifications SPECIFICATION Power Requirements Default Net ID Switch Type Load Type 2-Series Control System 1, 2 Update File Load Ratings 3 DETAILS Line Power, 120 VAC, 60 Hz -DIM: 6D -DIMS: 6E Dimmer Incandescent, Tungsten-Halogen, Magnetic Low Voltage Version 3. 093 or later Incandescent/Tungsten Halogen Magnetic Low Voltage 4 -DIM: 1000W -DIMS: 1000W -SLVD: N/A -DIM: 1000VA/750W -DIMS: 1000VA/750W -SLVD: N/A 32°F to 104°F (0°C to 40°C) 10 to 90% Relative Humidity (Non-Condensing) Operating Temperature and Humidity Dimensions and Weight 1. [. . . ] Wiring can be daisy chained, T-tapped, or home run back to the control system. Refer to the following wiring diagram. Wiring Diagram of CLW device to Cresnet 1. If installing multiple dimmers (-DIM or -DIMS), note the serial number on each device and make sure they are being installed in the proper location. Pull Class 2 low voltage wires through a hole in the drywall located outside of the electrical box, to the Crestron control system, a Crestron power supply, a Crestron C2N-NPA8, or a Crestron connection block device. Leave wires outside of the wallbox for connection to the -DIM or -DIMS. 3. NOTE: Alternate wiring methods may be used for the Class 2 wiring connection. Choose either "CLW-DIM / CLW-DIMS Wiring" or "CLW-DIMS with CLW-SLVD Wiring", shown on this page and the following page. NOTE: The GRAY (Cresnet) wires are not polarized. These wires can be connected to either the Y or Z line on a Cresnet port. NOTE: The BLACK wire (Cresnet ground) should not be grounded with the GREEN (Ground) wire on the -DIM/-DIMS/-SLVD. NOTE: Crestron recommends using Crestron's CresnetDM cable for connecting the -DIM and -DIMS to the Cresnet network. NOTE: Alternative wiring methods can be obtained from the Dealer/Tech Resources | Design Center section of the Crestron website (http://www. crestron. com/dealertech_resources/design_center/hot_design_tips_and_ diagrams/tech_sales_tips/). CLW-DIM / CLW-DIMS Wiring NOTE: The -DIM and-DIMS require a neutral wire for operation. If no neutral is present, contact a licensed electrician for installation or contact Crestron customer service for alternative wiring options. The following wiring diagram illustrates installation of the -DIM or -DIMS. Wiring Diagram for CLW-DIM or CLW-DIMS (without CLW-SLVD) Hot BLUE (-DIMS ONLY) Installation NOTE: The -DIMS must be installed in the same wallbox that contains the connections to the load. NOTE: The -DIM, -DIMS, and -SLVD require a neutral wire for operation. If no neutral is present, contact a licensed electrician for installation or contact Crestron Customer Service for alternative wiring options. Installing with power on can result in serious personal injury and damage to the device. NOTE: New installations should be checked for short circuits prior to installing the -DIM, -DIMS, or -SLVD. If the lights do not work or a breaker trips, check and correct the wiring or fixture (if necessary). Install the -DIM, -DIMS, or -SLVD only when the short is no longer present. The warranty is void if the -DIM, -DIMS, or -SLVD is installed and operated with a shorted load. 4 · Stand Alone Wall Box Dimmer : CLW-DIM, DIMS, & SLVD BLACK RED LINE 120VAC 60Hz Load WHITE Cresnet Neutral GREEN Ground Installation Guide ­ DOC. 5995B CLW-DIM, DIMS, & SLVD(W/A/B) NOTE: The RED (Load) and BLACK (Hot) wires are #14 AWG. This must be used when changing light bulbs to ensure that the load is fully disconnected from power. ADJ When the mode selection switch is in the "ADJ" position, the large button is used to switch between the "Button 1High" and "Button 1-Low" presets (typically "On" and "Off"). The lighting level can be manually adjusted using the two small buttons to raise (right button) and lower (left button) the lighting level. [. . . ] This warranty statement supercedes all previous warranties. Trademark Information All brand names, product names, and trademarks are the sole property of their respective owners. Windows95/98/Me/XP and WindowsNT/2000 are trademarks of Microsoft Corporation. NOTE: The device may be warm to the touch during operation. This is normal. Further Inquiries If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling the Crestron corporate headquarters at 1-888-CRESTRON [1-888-273-7876]. For assistance in your local time zone, refer to the Crestron website (www. crestron. com) for a listing of Crestron worldwide offices. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON CLW-DIM CLW-DIMS CLW-SLVD




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON CLW-DIM CLW-DIMS CLW-SLVD will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.