User manual CRESTRON CLT-2DIM8 CLX-2DIM8

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CRESTRON CLT-2DIM8 CLX-2DIM8. We hope that this CRESTRON CLT-2DIM8 CLX-2DIM8 user guide will be useful to you.


CRESTRON CLT-2DIM8 CLX-2DIM8 : Download the complete user guide (585 Ko)

Manual abstract: user guide CRESTRON CLT-2DIM8 CLX-2DIM8

Detailed instructions for use are in the User's Guide.

[. . . ] NOTE: Modules and terminal blocks must be installed into the lowest available spaces and continue toward the top of the enclosure. Terminal Block & Module Locations (Single-wide Enclosure) GROUNDING TERMINAL TERMINAL BLOCK BLOCK MODULE Industry Compliance This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc. Terminal Block & Module Locations (Double-wide Enclosure) TERMINAL BLOCK (LEFT) MODULE TERMINAL BLOCK (RIGHT) (E103692) Installation The terminal block and module must be mounted into a Crestron Automation Enclosure by a licensed electrician, in accordance with all national and local codes. CAUTION: This equipment is for indoor use only and needs to be air-cooled. The ambient temperature must be 32°F to 104°F (0°C to 40°C). Terminal blocks are installed along the left side of singlewide enclosures and along the outside edges (left and right sides) of double-wide enclosures. [. . . ] With the circuit breakers turned off, connect the circuit feed (LINE and NEUTRAL) and controlled circuit (LOAD) wires to the terminal block per the markings provided on the wiring label (as shown in the diagrams on this page). Tighten terminal blocks to 9 in-lbs. TERMINAL LEFT SIDE BLOCK WIRING LABEL Wiring Diagram of the Terminal Block to the Feed and Load(s) (Right Side Double-wide Enclosures) GND GROUNDING TERMINAL BLOCK NEUTRAL LINE 2 FROM 15 OR 20 AMP CIRCUIT BREAKER NEUTRAL BYPASS JUMPERS AREA FOR MODULE LOCATION LABEL LINE 1 TO LOAD(S) FROM 15 OR 20 AMP CIRCUIT BREAKER TERMINAL BLOCK RIGHT SIDE WIRING LABEL 2 · Terminal Block & Module: CLT- & CLX-2DIM8 Installation Guide ­ DOC. 6280B Crestron CLT- & CLX-2DIM8 Module Installation CAUTION: Module contains electrostatic sensitive devices (ESDs); unit must be handled from metal chassis ­ do not touch PC board or components. NOTE: Modules are to be installed after enclosure has been completely wired. Refer to the terminal block installation procedure on page 2 for details. Use the four supplied self-tapping pan Phillips screws (8B x ¼ length) to secure the module to the enclosure. As shown in the wiring diagrams (next column), connect the wires from the module to the terminal block. Each wire exits the module directly in line with, and is the same color as, the terminal to which it should be connected. If the module is being installed above another module within the enclosure, attach the supplied module interconnect cable between the two modules. The illustration below depicts the area within a double-wide enclosure where the corners of four modules meet. Terminal Block & Module control to the system, should be properly connected and contain a valid program to provide control of the module. Wiring Diagram of the Terminal Block to the Module (Single-wide and Left Side Double-wide Enclosures) BLACK FROM BREAKER RED TO LOADS WHITE FROM BREAKER PANEL WHITE TO LOADS BLACK FROM BREAKER RED TO LOADS WHITE FROM BREAKER PANEL WHITE TO LOADS 2. ATTACH MODULE INTERCONNECT CABLE AS DESCRIBED IN STEP 3 ENLARGEMENT DETAIL: LOCATION OF BYPASS JUMPERS ON TERMINAL BLOCK AS DESCRIBED IN STEP 5. JUMPERS ON WHITE SECTIONS REMAIN INSTALLED. 3. JUMPER REMOVED NOTE: One wire on the module interconnect cable may be a different color from the rest. The color has no bearing on its orientation during installation. Use Module Interconnect Cable to Wire Module to Module MODULE INTERCONNECT CABLE ATTACHED CONNECTION NOT MADE Wiring Diagram of the Terminal Block to the Module (Right Side Double-wide Enclosures) WHITE TO LOADS WHITE FROM BREAKER PANEL RED TO LOADS BLACK FROM BREAKER WHITE TO LOADS WHITE FROM BREAKER PANEL RED TO LOADS BLACK FROM BREAKER 4. Turn on the circuit breakers and verify that the green PWR LED on the module lights, the breakers do not trip, and power is delivered to the loads. Turn off the circuit breakers and remove the bypass jumpers on the black and red sections of the terminal block. The jumpers on the white sections of the terminal block must remain installed. Refer to the figures in the next column for a close-up of the jumpers. ATTACH MODULE INTERCONNECT CABLE AS DESCRIBED IN STEP 3 ENLARGEMENT DETAIL: LOCATION OF BYPASS JUMPERS ON TERMINAL BLOCK AS DESCRIBED IN STEP 5. JUMPERS ON RED AND BLACK SECTIONS HAVE BEEN REMOVED AFTER LOOSENING ALL SCREWS. JUMPERS ON WHITE SECTIONS REMAIN INSTALLED. 5. JUMPER INSTALLED JUMPER REMOVED NOTE: Before the bypass jumpers, shown in the illustration, are removed, the Crestron Professional Automation Computer (PAC2), which provides 6. Turn on the circuit breakers. Installation Guide ­ DOC. 6280B Terminal Block & Module: CLT- & CLX-2DIM8 · 3 Terminal Block & Module NOTE: Power must be supplied to LINE 1 for the module to communicate with the control system or for any of the circuits to operate. If the program is not running yet, loads can be tested by using Local Mode. Crestron CLT- & CLX-2DIM8 Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. [. . . ] Press the SETUP button again to turn off output 1 and turn on output 2. After turning on the last output, press the SETUP button again to turn on all outputs. Press the SETUP button once more to turn off all outputs and LEDs and exit Local Mode. 3. warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three (3) years from the date of purchase from CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and overlay components are covered for 90 days; batteries and incandescent lamps are not covered. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON CLT-2DIM8 CLX-2DIM8




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON CLT-2DIM8 CLX-2DIM8 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.