User manual CRESTRON CLT-1DIM8 CLX-1DIM8

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CRESTRON CLT-1DIM8 CLX-1DIM8. We hope that this CRESTRON CLT-1DIM8 CLX-1DIM8 user guide will be useful to you.


CRESTRON CLT-1DIM8 CLX-1DIM8 : Download the complete user guide (553 Ko)

Manual abstract: user guide CRESTRON CLT-1DIM8 CLX-1DIM8

Detailed instructions for use are in the User's Guide.

[. . . ] Terminal blocks are installed along the left side of singlewide enclosures and along the outside edges (left and right sides) of double-wide enclosures. Modules are installed along the right side of single-wide enclosures and side-by-side in the center of double-wide enclosures. When installing modules and terminal blocks in a doublewide enclosure, be sure to invert units on the right side so that they can be properly wired. Refer to the illustrations shown in the next column when considering the location of terminal blocks and modules within an enclosure. Crestron Electronics, Inc. [. . . ] 5985B Crestron CLT- & CLX-1DIM8 Module Installation CAUTION: Module contains electrostatic sensitive devices (ESDs); unit must be handled from metal chassis ­ do not touch PC board or components. NOTE: Modules are to be installed after enclosure has been completely wired. Refer to the terminal block installation procedure on page 2 for details. Use the four supplied self-tapping pan Phillips screws (8B x ¼ length) to secure the module to the enclosure. As shown in the wiring diagrams (next column), connect the wires from the module to the terminal block. Each wire exits the module directly in line with, and is the same color as, the terminal to which it should be connected. If the module is being installed above another module within the enclosure, attach the supplied module interconnect cable between the two modules. The illustration below depicts the area within a double-wide enclosure where the corners of four modules meet. Terminal Block & Module NOTE: Before the nine-position bypass jumper, shown in the illustration, is removed, the Crestron Professional Automation Computer (PAC2), which provides control to the system, should be properly connected and contain a valid program to provide control of the module. Wiring Diagram of the Terminal Block to the Module (Single-wide and Left Side Double-wide Enclosures) BLACK RED 2. WHITE ATTACH MODULE INTERCONNECT CABLE (DESCRIBED IN STEP 3) 3. ENLARGEMENT DETAIL: LOCATION OF NINE-POSITION BYPASS JUMPER ON TERMINAL BLOCK AS DESCRIBED IN STEP 5. JUMPER ON BLACK AND RED SECTION OF TERMINAL BLOCK HAS BEEN REMOVED AFTER LOOSENING ALL SCREWS. JUMPER NOTE: One wire on the module interconnect cable may be a different color from the rest. The color has no bearing on its orientation during installation. Use Module Interconnect Cable to Wire Module to Module MODULE INTERCONNECT CABLE ATTACHED CONNECTION NOT MADE Wiring Diagram of the Terminal Block to the Module (Right Side Double-wide Enclosures) WHITE RED BLACK JUMPER 4. Turn on the circuit breaker and verify that the green PWR LED on the module lights, the breaker does not trip, and proper loads are energized. Turn off the circuit breaker and remove the nineposition bypass jumper on the black and red section of the terminal block. The jumper on the white section of the terminal block remains installed. Refer to the figures in the next column for a close-up of the jumpers. ATTACH MODULE INTERCONNECT CABLE (DESCRIBED IN STEP 3) 5. ENLARGEMENT DETAIL: LOCATION OF NINE-POSITION BYPASS JUMPER ON TERMINAL BLOCK AS DESCRIBED IN STEP 5. JUMPER ON BLACK AND RED SECTION OF TERMINAL BLOCK HAS BEEN REMOVED AFTER LOOSENING ALL SCREWS. Installation Guide ­ DOC. 5985B Terminal Block & Module: CLT- & CLX-1DIM8 · 3 Terminal Block & Module 6. If the program is not running yet, loads can be tested by using Local Mode. Crestron CLT- & CLX-1DIM8 Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number, and return address. Products may be returned for credit, exchange, or service with a CRESTRON Return Merchandise Authorization (RMA) number. Authorized returns must be shipped freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N. J. , or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. [. . . ] warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three (3) years from the date of purchase from CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and overlay components are covered for 90 days; batteries and incandescent lamps are not covered. This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if any. CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended, or if it has been subjected to misuse, accidental damage, modification, or improper installation procedures. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON CLT-1DIM8 CLX-1DIM8




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON CLT-1DIM8 CLX-1DIM8 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.