User manual CRESTRON CLT-1DIM4 CLX-1DIM4

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CRESTRON CLT-1DIM4 CLX-1DIM4. We hope that this CRESTRON CLT-1DIM4 CLX-1DIM4 user guide will be useful to you.


CRESTRON CLT-1DIM4 CLX-1DIM4 : Download the complete user guide (476 Ko)

Manual abstract: user guide CRESTRON CLT-1DIM4 CLX-1DIM4

Detailed instructions for use are in the User's Guide.

[. . . ] CAUTION: This equipment is for indoor use only and needs to be air-cooled. The ambient temperature must be 32°F to 104°F (0°C to 40°C). Terminal blocks are installed along the left side of singlewide enclosures and along the outside edges (left and right sides) of double-wide enclosures. Modules are installed along the right side of single-wide enclosures and side-by-side in the center of double-wide enclosures. [. . . ] Furthermore, the jumper on the white section of the terminal block ties the neutral in to the neutral outs. With the circuit breakers turned off, connect the circuit feed (LINE and NEUTRAL) and controlled circuit (LOAD) wires to the terminal block per the markings provided on the wiring label (as shown in the diagrams on this page). Tighten terminal blocks to 9 in-lbs. LEFT SIDE WIRING LABEL TERMINAL BLOCK Wiring Diagram of the Terminal Block to the Feed and Load(s) (Right Side Double-wide Enclosures) CLX-1DIM4 1 FEED 4 DIM 120VAC 60 Hz 16A MAX BYPASS JUMPER N OUT 4 N OUT 3 N OUT 2 N OUT 1 N IN DIM 4 DIM 3 DIM 2 DIM 1 LINE GND NEUTRAL LINE (FROM 15 OR 20 AMP CIRCUIT BREAKER) TO LOAD(S) GROUNDING TERMINAL BLOCK CRESTRON AREA FOR MODULE LOCATION LABEL TERMINAL BLOCK RIGHT SIDE WIRING LABEL 2 · Terminal Block & Module: CLT- & CLX-1DIM4 Installation Guide ­ DOC. 5987C Crestron CLT- & CLX-1DIM4 Module Installation CAUTION: Module contains electrostatic sensitive devices (ESDs); unit must be handled from metal chassis ­ do not touch PC board or components. NOTE: Modules are to be installed after enclosure has been completely wired. Refer to the terminal block installation procedure on page 2 for details. Use the four supplied self-tapping pan Phillips screws (8B x ¼ length) to secure the module to the enclosure. As shown in the wiring diagrams (next column), connect the wires from the module to the terminal block. Each wire exits the module directly in line with, and is the same color as, the terminal to which it should be connected. If the module is being installed above another module within the enclosure, attach the supplied module interconnect cable between the two modules. The illustration below depicts the area within a double-wide enclosure where the corners of four modules meet. Terminal Block & Module Professional Automation Computer (PAC2), which provides control to the system, should be properly connected and contain a valid program to provide control of the module. Wiring Diagram of the Terminal Block to the Module (Single-wide and Left Side Double-wide Enclosures) BLACK RED 2. WHITE 3. ATTACH MODULE INTERCONNECT CABLE (DESCRIBED IN STEP 3) ENLARGEMENT DETAIL: LOCATION OF FIVE-POSITION BYPASS JUMPER ON TERMINAL BLOCK AS DESCRIBED IN STEP 5. JUMPER ON BLACK AND RED SECTION OF TERMINAL BLOCK HAS BEEN REMOVED AFTER LOOSENING SCREWS. JUMPER ON WHITE SECTION REMAINS INSTALLED. NOTE: One wire on the module interconnect cable may be a different color from the rest. The color has no bearing on its orientation during installation. Use Module Interconnect Cable to Wire Module to Module MODULE INTERCONNECT CABLE ATTACHED CONNECTION NOT MADE JUMPER Wiring Diagram of the Terminal Block to the Module (Right Side Double-wide Enclosures) WHITE RED BLACK 4. Turn on the circuit breaker and verify that the green PWR LED on the module lights, the breaker does not trip, and power is delivered to the loads. Turn off the circuit breaker and remove the fiveposition bypass jumper on the black and red section of the terminal block. The bypass jumper on the white section of the terminal block remains installed. Refer to the figures in the next column for a close-up of the jumpers. ATTACH MODULE INTERCONNECT CABLE (DESCRIBED IN STEP 3) JUMPER 5. ENLARGEMENT DETAIL: LOCATION OF FIVE-POSITION BYPASS JUMPER ON TERMINAL BLOCK AS DESCRIBED IN STEP 5. JUMPER ON BLACK AND RED SECTION OF TERMINAL BLOCK HAS BEEN REMOVED AFTER LOOSENING SCREWS. NOTE: Before the five-position bypass jumper, shown in the illustration, is removed, the Crestron Installation Guide ­ DOC. 5987C Terminal Block & Module: CLT- & CLX-1DIM4 · 3 Terminal Block & Module 6. NOTE: Power must be supplied to LINE for the module to communicate with the control system or for any of the circuits to operate. [. . . ] The SETUP LED and output LED 1 illuminate and power is applied to the loads connected to the DIM1 output. Press the SETUP button again to turn off output 1 and turn on output 2. After turning on the last output, press the SETUP button again to turn on all outputs. Press the SETUP button once more to turn off all outputs and LEDs and exit Local Mode. 2. 2. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON CLT-1DIM4 CLX-1DIM4




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON CLT-1DIM4 CLX-1DIM4 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.