[. . . ] For example, 7x2 and 4x2 are double-wide enclosures that hold up to 14 and 8 modules, respectively. Refer to the illustration and table on this page for an alphanumeric listing of CAEN models, overall dimensions, and weight. NOTE: The PAC2 occupies two module spaces in a double-wide enclosure and one module space in a singlewide. NOTE: Four keyholes are located within the enclosure and should be used if surface mounting.
CAEN Overall Dimensions (Front and Side Views)
W1 W2 W3 W4 W3 H2
Industry Compliance
This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
(E227280)
Functional Summary
·
· · · ·
Houses Crestron Lighting Modules, Terminal Blocks, Professional Automation Computer, and third-party products with or without Crestron Universal Mounting Plates Flush or surface mounted installation Ventilated cover for convection cooling of dimming modules Conveniently located electrical knockouts for both Class 1 and Class 2 wiring 16 gauge hot dipped galvanized steel
Specifications 1 DIMENSIONS CAEN- CAEN- CAEN- CAEN- CAEN7x2 7x1 4x2 4x1 2x1
H1 H2 H3 W1 W2 W3 W4 W5
2
W6 D1
H1 H3
Cover Thickness Cover Height Cover Width Weight (empty) Maximum Weight (filled) 1. [. . . ] If you require a UL Listed panel, Crestron offers this service through its UL Listed panel shop. This includes complete in factory system configuration and assembly by Crestron for an additional fee. NOTE: Install modules into the lowest available spaces and continue toward the top of the enclosure. NOTE: When flush mounting, 5/8" drywall is preferred.
Crestron CAEN
Tighten all CLT-Series terminal block screws and grounding terminal block screws to the torque specified in the Torque Data table. CAUTION: Failure to properly tighten the screws may result in poor electrical connection and overheating of the terminals.
Torque Data CLT Terminal Blocks
Wire Range Torque (In-Lbs) 22 - 10 9
Grounding Terminal Blocks
14 - 10 35 8 40 6-4 45
Key Typical Products in a CAEN Enclosure
CLX-SERIES CLT-SERIES TERMINAL MODULE BLOCKS
PROFESSIONAL GROUNDING TERMINAL AUTOMATION BLOCKS COMPUTER
Mounting Details - Single-Wide CAEN
Wiring
CAUTION: All power feeds must be protected by 15 or 20 amp circuit breakers (supplied by others). NOTE: Use copper conductors only rated 60°C NOTE: All wiring must be installed in accordance with all local and national electrical codes. If required, insert into knockouts at the bottom of the enclosure to prevent damage to low voltage wiring. Refer to the following illustrations showing single-wide and double-wide wiring details. Areas for high voltage (Class 1) wiring are shown along the top and side(s) of the unit. The lower area is reserved for low voltage (Class 2) wiring.
MOUNT CLT TO THIS COLUMN
CLT TERMINAL BLOCKS MUST BE MOUNTED TO THE HOLES SHOWN ABOVE
2 · Automation Enclosures: CAEN
Installation Guide DOC. 5940C
Crestron CAEN
Wiring Details - Single-Wide CAEN
CLASS 1 WIRING ONLY
Automation Enclosures
Mounting Details - Double-Wide CAEN
C L A S S 1 W I R I N G O N L Y
MOUNT CLT TO THIS COLUMN MOUNT CLT TO THIS COLUMN
CLASS 2 WIRING ONLY
CLT TERMINAL BLOCKS MUST BE MOUNTED TO THE HOLES SHOWN ABOVE
Wiring Details - Double-Wide CAEN
CLASS 1 WIRING ONLY
C L A S S 1 W I R I N G O N L Y
C L A S S 1 W I R I N G O N L Y
CLASS 2 WIRING ONLY
Installation Guide DOC. 5940C
Automation Enclosures: CAEN · 3
Automation Enclosures Further Inquiries
If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling the Crestron corporate headquarters at 1-888-CRESTRON [1-888-273-7876]. For assistance in your local time zone, refer to the Crestron website (www. crestron. com) for a listing of Crestron worldwide offices. You can also log onto the online help section of the Crestron website to ask questions about Crestron products. First-time users will need to establish a user account to fully benefit from all available features.
Crestron CAEN
Return and Warranty Policies
Merchandise Returns / Repair Service
1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number, and return address. Products may be returned for credit, exchange, or service with a CRESTRON Return Merchandise Authorization (RMA) number. Authorized returns must be shipped freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N. J. , or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. [. . . ] CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty. Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or implied, nor authorizes any other party to offer any warranty, including any implied warranties of merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are limited to the terms of this limited warranty. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON CAEN
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON CAEN will begin.