User manual CRESTRON ACTIVE CNX

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CRESTRON ACTIVE CNX. We hope that this CRESTRON ACTIVE CNX user guide will be useful to you.


CRESTRON ACTIVE CNX : Download the complete user guide (340 Ko)

Manual abstract: user guide CRESTRON ACTIVE CNX

Detailed instructions for use are in the User's Guide.

[. . . ] These inputs go into the control system and appear to the control system as an "e-control PC Interface" symbol. From that point, the user programs the SIMPL logic as if the system was a real touchpanel. When a signal changes on the inputs of the "e-control PC Interface", a message is sent to the ActiveCNX control. There are three main control events that the user can capture and utilize in a PC program. [. . . ] Dynamic - This property is only used with CEN devices, therefore this property is ignored if used with the CNMSX control system. If this value is set to TRUE, a dynamic entry is added into the device's IP ID table. Otherwise, to get feedback to the application, a static entry must be manually added to the IP table in the CEN device (refer to the latest revision of the specific CEN documentation). There is only one connection per ActiveCNX Control so if connect is called the second time Disconnect() is automatically called and Connect() is issued again with the new properties. For multiple connections per application, simply drop multiple ActiveCNX controls on the form. Methods The general procedure for using the components methods are to first call Connect() to start the control session and when complete call Disconnect(). Between Connect() and Disconnect() any combination of the sending and receiving the three data types can be used. At anytime during development if the programmer needs to see Introduction & Tutorial - DOC. 5777A Active CNX · 3 Software Crestron Active CNX methods, properties, or events available for the ActiveCNX they can bring up the "Object Browser" in Visual Basic. The Object browser list for the ActiveCNX control is shown below. Object Browser List Events OnDigital OnAnalog OnSerial OnError OnConnect OnDisconnect The ActiveCNX control also triggers events used for feedback and for handling errors. In "design mode" the user can select the ActiveX component from the combo box on the left then select which event to capture. Once the event is selected, it is entered into the program as a "sub procedure". From this point, the programmer can handle the signal however they choose. For example, a digital "on" could signal another component to send a specific email. For example if a temperature sensor value on the Cresnet network changes and the signal is fed into the "Virtual Touch Panel" symbol the OnAnalog event is fired with its join number and the analog value (Long) as parameters. The OnConnect() event is only fired if the connection is successful after calling the Connect() method. If Connect() fails for some reason the type and description is sent to the OnError() event. The OnDisconnect() event is only fired if there is a successful disconnection. 4 · Active CNX Introduction & Tutorial - DOC. 5777A Crestron Active CNX Software Errors When an error occurs the OnError() event is triggered with one of the following parameters and a description string. ERROR CODES: CNX_BASEERROR CNX_CANNOT_CREATE CNX_ALREADY_CONN CNX_NOT_CONN CNX_NETDOWN CNX_CONNRESET CNX_CONNABORTED CNX_CONNREFUSED CNX_CONNCLOSED CNX_INVALID_IP CNX_NOT_AVAIL CNX_TIMEDOUT CNX_NOT_SOCK CNX_NOTCONNECTED CNX_REJECT CNX_GENERAL CNX_NOTCIPNODE 7000 7001 7002 7003 7004 7005 7006 7007 7008 7009 7010 7011 7012 7013 7014 7015 7016 Can not create socket. Already connected Not connected to server The Windows Sockets implementation detected that the network subsystem failed. Destination IP is not a valid CIP node Introduction & Tutorial - DOC. 5777A Active CNX · 5 Software Crestron Active CNX Software License Agreement This License Agreement ("Agreement") is a legal contract between you (either an individual or a single business entity) and Crestron Electronics, Inc. [. . . ] Crestron shall, at its option, repair or replace or refund the license fee for any Software found defective by Crestron if notified by you within the warranty period. The foregoing remedy shall be your exclusive remedy for any claim or loss arising from the Software. CRESTRON shall not be liable to honor warranty terms if the product has been used in any application other than that for which it was intended, or if it as been subjected to misuse, accidental damage, modification, or improper installation procedures. Furthermore, this warranty does not cover any product that has had the serial number or license code altered, defaced, improperly obtained, or removed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON ACTIVE CNX




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON ACTIVE CNX will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.