User manual CONWIN DUPLICATOR 2 INFLATOR

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CONWIN DUPLICATOR 2 INFLATOR. We hope that this CONWIN DUPLICATOR 2 INFLATOR user guide will be useful to you.


CONWIN DUPLICATOR 2 INFLATOR : Download the complete user guide (253 Ko)

Manual abstract: user guide CONWIN DUPLICATOR 2 INFLATOR

Detailed instructions for use are in the User's Guide.

[. . . ] Contact an authorized Conwin Service Center for details on how to receive service. Opening the Duplicator 2 case will automatically void manufacturer warranty. Contact an authorized Conwin Service Center for all repairs. · · · · · · · 1 Duplicator 2 Inflator 1 Helium/Nitrogen Regulator 1 Adjustable Regulator 1 Supply Hose 1 Latex Balloon Filling Outlet 1 Power Cord 1 Foot Pedal Vie w a de monstratio n of the Duplic ator 2 on Conw in's Tools of th e Trade DV D Primary Regulator Ribbon Cutter Latex Balloon Outlet Digital Timer Readout Adjustable Regulator Foil Balloon Outlet Disc Tyer Post Hand-tight Connection 1 2 Press-Fit Connection 3 Hand-tighten the regulator to a helium or nitrogen cylinder. Make sure the cylinder is properly secured in a safety stand or wall bracket prior to attaching the regulator. [. . . ] To adjust the pressure, pull the black setting knob up to unlock and turn it clockwise to increase the pressure and the size of the balloon. Turn the knob counter-clockwise to decrease the pressure and reduce the size of the balloon. When the unit is set to the desired size, press the black knob down to lock it in place. BALLOON SIZE HELIUM N/A NITROGEN 0. 2 Seconds 95 PSI 1. 6 Seconds 80 PSI 2. 7 Seconds 80 PSI 5. 0 Seconds 80 PSI 7. 4 Seconds 80 PSI AIR COMPRESSOR 0. 3 Seconds 70 PSI 1. 9 Seconds 80 PSI 3. 5 Seconds 80 PSI 6. 4 Seconds 80 PSI N/A N/A 5" N/A 0. 6 Seconds 2 9" 70 PSI 1. 0 Seconds 11" 80 PSI Set the Inflation Time Reference the chart (see right) to determine the appropriate number of seconds required for the inflation cycle. The digital display will indicate number of seconds. 1. 9 Seconds 14" 80 PSI 3. 0 Seconds 3 16" 80 PSI Settings for 60/40 Helium/Air Outlet (optional) Place the balloon over the inflating outlet. This will insure the gas enters the center of the balloon and the round shape of the balloon is maintained during the inflation process. It is important to inflate a test balloon at each adjustment until the desired size is produced. Conwin's Duplicator 2 Inflators feature a raised button on the cycle switch to enable one-hand inflation. Workers can hold the balloon over the filling outlet and activate the inflation cycle by pressing the button with the base of their hand. When the system automatically shuts-off, remove the balloons from the outlets without allowing any of the air to escape. The following settings should be used as guidelines when using the optional 60/40 Helium/Air Outlet with the Duplicator 2. The 60/40 Helium/Air Outlet is recommended for use with 14" or larger balloons. Conwin #55413 BALLOON SIZE 60/40 HELIUM/ AIR OUTLET 4. 3 Seconds 14" 80 PSI 6. 6 Seconds 16" 80 PSI Foil Balloon Inflation 1 2 1) Set the Adjustable Regulator on the back of the Duplicator 2 to 80 PSI when inflating foil balloons. 2) Place the foil balloon over the brass inflating outlet. Pinch the neck of the balloon between thumb and forefinger and press down on the outlet. Support the foil balloon in an upright position until enough helium has entered the balloon to hold it up. This insures the neck of the balloon does not fold over and restrict the flow of helium. When the balloon has reached the proper pressure the Duplicator 2 will automatically shut off the helium flow. Shutting Down the Duplicator 2 1 2 Close the cylinder valve or shut off the air compressor. Cycle the system until all the pressure has been released from the unit. Disconnect the supply hose and adjustable regulator from the back of the unit. Remove regulator from the cylinder. Recommendations For Use With An Air Compressor Most air compressors are factory set to automatically cycle on at 90 PSI and automatically cycle off at 120 PSI. [. . . ] This fast and easy-to-use tool efficiently fills large balloons with the maximum number of small balloons. The Insider can be clamped to any convenient table or workstation. 60/40 Helium/Air Outlet The 60/40 Helium/Air Outlet enables the user to inflate 14" or larger balloons with a mixture of 60% helium and 40% air. The 60/40 helium/Air Outlet easily attaches to the Duplicator 2 Portable Power Pack Cylinder Safety Stand Helium/ Hi-Float Adapter Air Compressor Hook-Up Provides power for over 5 hours of continual use. It's a must for on-the-job decorating! A must for safety in the shop and on the job! Save time by dispensing Hi-FloatTM and inflating balloons right from the pump outlet. The Air Compressor Hook-Up, with quickdisconnect fittings, allows user to operate Duplicator 2 up to 12-ft. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CONWIN DUPLICATOR 2 INFLATOR




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CONWIN DUPLICATOR 2 INFLATOR will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.