User manual CONWIN DUAL SPLIT-SECOND SIZER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CONWIN DUAL SPLIT-SECOND SIZER. We hope that this CONWIN DUAL SPLIT-SECOND SIZER user guide will be useful to you.


CONWIN DUAL SPLIT-SECOND SIZER : Download the complete user guide (331 Ko)

Manual abstract: user guide CONWIN DUAL SPLIT-SECOND SIZER

Detailed instructions for use are in the User's Guide.

[. . . ] The cylinder pressure will read on the gauge located on the regulator. The inlet pressure will read on the second stage regulator gauge, located on the back of the unit. Setting the Dual Split-Second Sizer 1 2 On/Off LED Mode Indicator 3 4 Reference the size setting chart below and set the Dual Split-Second Sizer to the appropriate time and pressure settings. To adjust the inlet pressure, pull the knob up to release it and turn it clockwise to increase the pressure and speed of inflation. To decrease the size of the balloon and speed of inflation, turn the knob counter-clockwise. [. . . ] The 60/40 Helium/Air Outlet is recommended for use with 14" or larger balloons. (See back page for details). 0. 3 Seconds 0. 3 Seconds 75 PSI 1. 9 Seconds 75 PSI 75 PSI 1. 9 Seconds 75 PSI 5" N/A 0. 6 Seconds 9" 70 PSI 1. 1 Seconds 3. 7 Seconds 3. 4 Seconds 75 PSI 75 PSI BALLOON SIZE 60/40 HELIUM/AIR OUTLET 1 Outlet 4. 2 Seconds 2 Outlets 4. 4 Seconds 80 PSI 6. 9 Seconds 80 PSI 11" 70 PSI 2. 0 Seconds 6. 5 Seconds 6. 3 Seconds 75 PSI 9. 9 Seconds 90 PSI 90 PSI N/A N/A 14" 80 PSI 6. 6 Seconds 14" 70 PSI 3. 2 Seconds 16" 70 PSI 16" 80 PSI 2 Auto-Fill Foil Outlet Instructions 1. The Dual Split-Second Sizer includes a quick disconnect port located on the back of the unit. The Auto-Fill Foil Outlet will easily snap into place when pushed into the port. Pinch the neck of the balloon between thumb and forefinger and press down on the outlet. Support the foil balloon in an upright position to insure the neck of the balloon does not fold over the outlet and restrict the flow of helium. When the balloon has reached the proper pressure the inflator will automatically shut off the helium flow. Remove the balloon from the outlet and attach a ribbon and a balloon weight. 1 2 Double Bubble Inflation Instructions 1 2 3 4 1. Press-fit the Double Bubble Outlet onto the inflating outlets of the Dual Split-Second Sizer. Attach the yellow hose to the right outlet and the blue hose to the left outlet. 2. Reference the following chart to set the unit to properly inflate the balloons. After the balloons are fully inflated, pinch the neck of the balloons together and remove the Double Bubble outlet quickly to prevent helium from escaping. 3. Place the 16" balloon over the 11" balloon and the yellow hose. Hold firmly to prevent helium from escaping during the inflation process. 5 Double Bubble Balloon Size Chart Inside Balloon: 11" 60 PSI Left outlet, blue hose, Dual Sizer Setting: 1. 7 Seconds Outside Balloon: 16" 60 PSI Right outlet, yellow hose, Dual Sizer Setting: 3. 7 Seconds Tying Double Bubble Balloons 1 1. Pull the neck of the inside 11" balloon while pinching the necks of the 2 balloons together. 2 2. Stretch the neck of the inside 11" balloon around the neck of the outside 16" balloon. 3 3. Tie off the balloon. 3 Air Compressor Recommendations Most air compressors are factory set to automatically cycle on at 90 PSI and automatically cycle off at 120 PSI. The Dual Split-Second Sizer must have a steady supply of air or gas to produce equal size balloons. For accurate sizing, it is essential to work within the limits of the cubic foot per minute capacity of the air compressor. Air Compressor Required Specifications · Primary Moisture Filter · 20 Gallon Storage Tank · Cycle Pressure: 90 PSI On - 120 PSI Off · Compressed Air Availability: 6. 5 Cubic Foot/Minute @ 90 PSI Important Guidelines When Using an Air Compressor · Compressor must build up the tank pressure before inflating balloons. [. . . ] Conwin # 36330 Helium/ Hi-Float Adapter Save time by dispensing Hi-FloatTM and inflating balloons right from the pump outlet. Conwin # 36400 HI-FLOAT® Outlet The hand-tight HI-FLOAT® Outlet enables the user to inflate balloons filled with HI-FLOAT® neck up. This prevents any HI-FLOAT® from getting into the Dual Split-Second Sizer. Conwn # 36320 60/40 Helium-Air Outlet The 60/40 Helium/Air Outlet enables the user to inflate 14" or larger balloons with a mixture of 60% helium and 40% air. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CONWIN DUAL SPLIT-SECOND SIZER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CONWIN DUAL SPLIT-SECOND SIZER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.