If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CONSTRUCTA CWA4A100IL. We hope that this CONSTRUCTA CWA4A100IL user guide will be useful to you.


CONSTRUCTA CWA4A100IL : Download the complete user guide (934 Ko)

You may also download the following manuals related to this product:

   CONSTRUCTA CWA4A100IL annexe 1 (3665 ko)

Manual abstract: user guide CONSTRUCTA CWA4A100IL

Detailed instructions for use are in the User's Guide.

[. . . ] ­ Where an exhaust air duct is routed to the open air, a drain check valve must be fitted (prevents air from flowing back). ­ Only install the air extraction system as described in these instructions. ­ The air extraction system must not exceed the specified pressure losses, see page 3. When operating the dryer without an exhaust air duct, the following must also be observed: ­ Ensure that the room is well ventilated, otherwise energy consumption and drying time will increase. [. . . ] Through a wall box into chimneys or ventilation shafts ­ It is not permitted to connect the exhaust air duct to chimneys which are connected to gas or coal-fired ovens/cookers or gas-fired heating systems. ­ If the appliance is being connected to a moisture-insulated ventilation shaft the responsible chimney sweep must be informed and the approval of the local building department (building supervision office) or the owner of the building must be obtained. ­ If other appliances are operated in the room where the appliance is installed or in adjoining rooms, e. g. gas-fired heating systems, gas-fired boilers, coal-fired ovens connected to a chimney, or open fireplaces, a vacuum may be created, leading to waste gases being sucked back -> risk of poisoning. ­ In every case, have safe operation confirmed by the responsible chimney sweep, boiler engineer, ventilation specialist, etc. Condensation outlet If there is a high level of condensation in the exhaust air duct, it is advisable to fix a condensation collector (standard) or a drain hole with a diameter of approximately 3 mm to the lowest part of the exhaust air duct. Installation for pipe connection - inside diameter = 100 mm If the pipe connection has an inside diameter > 100 mm and a total pressure loss greater than 50*, increase the inside diameter of the pipe connection * To determine the total pressure loss see table -> page 6. 1 2 3 4 Notes on installation Individual pressure loss values Pipe connection diameter > 100 mm Internal wall Pipe, smooth Flexible pipe, grooved Flat duct connection 220 x 54 smooth Installing more than one dryer Up to 7 exhaust air dryers can be connected to an intercepting pipe with a smooth internal wall. The following points MUST be observed: ­ It is imperative that there are drain check valves in the interception pipe for every dryer. These valves prevent the moist exhaust air from flowing back into the washing and drying room through dryers which are not in operation. ­ The outlet for the exhaust air must be arranged/routed in such a way as to prevent any additional backpressure (e. g. ­ In every case, have safe operation confirmed by the responsible ventilation engineer/ installer. Flexible 110 x 54 pipe, cor- smooth rugated Exhaust air duct for tumble dryer Model variant straight piece per 1 m length Fixtures 4 6 12 10 3 Bend R = 300 mm R = 200 mm R = 100 mm 3 4 6 5 7 9 7 8 10 6 8 12 3 4 6 When connecting to the interception pipe, avoid the following: mutual interference between dryers discharge of moisture in the washing and drying room higher pressure losses (increase in energy consumption and time) The exhaust air ducts of the individual dryers (DT = R >= 100 mm) should already be extended to the dimension of the interception pipe upstream of the drain check valves. caused by wind ingress) can be minimised by using a 90° bend, facing down. ­ ­ ­ ­ en Diverters Angle 10 16 17 26 8 *458208* Elbow 19 22 24 > 50 17 0809 / 9000458208 Telescopic wall box with grid Wall box with backpressure flap 14 6 28 13 7 3 Total pressure loss values Total pressure loss 0 - 50 0 -80 Pipe connection 100 110 120 130 Installation instructions Do not operate the exhaust air duct until you have read these instructions. Please also observe the separate instruction manual for the exhaust air dryer. Keep all the documents in a safe place for future reference, or to pass on to the next owner. 6 7 Contents Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Connections on the dryer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Notes on installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Notes on installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Installing more than one dryer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Connections on the dryer Connections for an exhaust air duct are located on the back panel and on the left side panel of the dryer. 1. Back panel connection The exhaust air opening on the back panel is open when the dryer is delivered (bayonet ring). The exhaust air opening on the left side panel is sealed with a cover. Safety instructions ­ We recommend that you route the exhaust air directly into the open air through an exhaust air duct. ­ Where an exhaust air duct is routed to the open air, a drain check valve must be fitted (prevents air from flowing back). [. . . ] ­ In every case, have safe operation confirmed by the responsible chimney sweep, boiler engineer, ventilation specialist, etc. Installation for pipe connection - inside diameter = 100 mm If the pipe connection has an inside diameter > 100 mm and a total pressure loss greater than 50*, increase the inside diameter of the pipe connection * To determine the total pressure loss see table -> page 6. 3 4 Notes on installation Individual pressure loss values Pipe connection diameter > 100 mm Internal wall Pipe, smooth Flexible pipe, grooved Flat duct connection 220 x 54 smooth Flexible 110 x 54 pipe, cor- smooth rugated Model variant straight piece per 1 m length Fixtures 4 6 12 10 3 Bend R = 300 mm R = 200 mm R = 100 mm 3 4 6 5 7 9 7 8 10 6 8 12 3 4 6 Diverters Angle 10 16 17 26 8 *458208* Elbow 19 22 24 > 50 17 0809 / 9000458208 Telescopic wall box with grid Wall box with backpressure flap 14 6 28 13 7 3 Total pressure loss values Total pressure loss 0 - 50 0 -80 Pipe connection 100 110 120 130 6 Installing more than one dryer Up to 7 exhaust air dryers can be connected to an intercepting pipe with a smooth internal wall. The following points MUST be observed: ­ It is imperative that there are drain check valves in the interception pipe for every dryer. These valves prevent the moist exhaust air from flowing back into the washing and drying room through dryers which are not in operation. ­ The outlet for the exhaust air must be arranged/routed in such a way as to prevent any additional backpressure (e. g. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CONSTRUCTA CWA4A100IL




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CONSTRUCTA CWA4A100IL will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.