User manual COBRA CPI 480 QUICK START GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual COBRA CPI 480. We hope that this COBRA CPI 480 user guide will be useful to you.


COBRA CPI 480 QUICK START GUIDE: Download the complete user guide (429 Ko)

Manual abstract: user guide COBRA CPI 480QUICK START GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] Introduction Our Thanks to You Our Thanks CPI 480 Thank you for purchasing the Cobra to You inverter. Properly used, this Cobra product will give you many years of reliable service. Operating Instructions How Your Cobra Power Inverter Works The Cobra power inverter is an electronic product that has been designed and built to take low voltage DC (Direct Current) power from your automobile or other low voltage power supplies and convert it to standard 115 Volt AC (Alternating Current) power like the current you have in your home. This conversion process thereby allows you to use many of your household appliances and electronic products in automobiles, RVs, boats, tractors, trucks and virtually anywhere else. The Cobra line of quality products includes: Customer Assistance CB Radios microTALK® Radios Radar/Laser Detectors Safety Alert® Traffic Warning Systems Mobile GPS Navigation Systems HighGear® Accessories CobraMarine® VHF Radios CobraMarine® Chartplotters Power Inverters Accessories Customer Assistance Should you encounter any problems with this product, or not understand its many features, please refer to this owner's manual. If you require further assistance after reading this manual, Cobra Electronics offers the following customer assistance services: For Assistance in the U. S. A. [. . . ] Make sure that ventilation openings on the ends of the unit are not obstructed. CAUTION To avoid fire, do not cover or obstruct ventilation openings. CAUTION The inverter must only be connected to batteries with a nominal output voltage of 12 volts. It will not work with a 6 volt battery, and will be damaged if it is connected to a 16 volt battery. WARNING This unit contains components which can produce arcs or sparks. To prevent fire or explosion, do not install in compartments containing a battery or flammable materials, or in a location which requires ignition protected equipment. Connect Test Load The inverter should supply power to the load. If the inverter is not working properly, refer to the troubleshooting guide on page 14 or power and protection indicators section on page 12. USB Connection 4 Nothing Comes Close to a Cobra® 5 Installation Mounting and Connecting Cables · Installation Connecting Cables Mounting To mount your inverter: 1. Place the inverter on a flat surface with the mounting bracket against the mounting surface. Mounting Brackets 2. Connect cable to the Power Input Terminals on right side panel of the inverter. The red terminal is positive (+) and the black terminal is negative (-). Insert the ends of the cables onto the terminals and tighten the screws to clamp the cables safely. Connect Terminals 2. Connect the cable from the Positive (Red) Terminal of the inverter to the Positive Terminal of the power source (the battery's main fuse or the battery selector switch, if you are using one). You might observe a spark when you make this connection since current can flow to charge capacitors in the inverter. All power connections to your Cobra inverter must be Positive to Positive and Negative to Negative. Connect Power Source CAUTION Do not connect the inverter and another AC source (such as a generator or utility power) to the AC wiring at the same time. The inverter will be damaged if its output is connected to AC voltage from another source. CAUTION Do not connect the inverter to an AC branch circuit that has high-power consumption loads. It will not operate electric heaters, air conditioners, stoves, and other electrical appliances that consume more than 400 watts. CAUTION Loose connectors result in excessive voltage drop and may cause over heated wires and melted insulation. CAUTION Reverse polarity connections (positive to negative) will blow external fuse in the inverter and may permanently damage the unit. Be careful not to short circuit the battery with any metallic object (wrench, etc. ). Do not work on AC wiring when it is connected to the inverter (even if it is switched off) unless the DC power source is physically disconnected from the inverter. Also, do not work on AC wiring if it is connected to another AC power source such as a generator or the utility line. WARNING You may observe a spark when making the connection because current can flow to charge the capacitors in the inverter. [. . . ] The inverter will normally start single phase induction motors rated at one-half HP or less. Input Voltage The inverter will operate from input voltage ranging from 10 volts to 15 volts. Optimum performance will occur when the voltage is between 12 volts and 14 volts. If the voltage drops below 10. 5V+/-0. 3V, an audible low battery warning will sound. The inverter will shut down if the input voltage drops below 9. 5V+/-0. 3V. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE COBRA CPI 480




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual COBRA CPI 480 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.