User manual COBRA CPI 200 CH

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual COBRA CPI 200 CH. We hope that this COBRA CPI 200 CH user guide will be useful to you.


COBRA CPI 200 CH : Download the complete user guide (304 Ko)

Manual abstract: user guide COBRA CPI 200 CH

Detailed instructions for use are in the User's Guide.

[. . . ] A test load such as a lamp or other small appliance that can be plugged into the AC receptacle on the inverter. QUICK CHECKOUT CAUTION Certain rechargers for small nickel cadmium batteries can be damaged if connected to the CPI 200 CH. Small battery operated appliances that can be plugged directly into an AC receptacle for recharging, including flashlights, razors, and night lights. Certain battery chargers for battery packs used in hand power tools, specifically those that have a WARNING label stating that dangerous voltages are present at the battery terminals. 1 Connecting to the Power Source 2 Your CPI 200 CH comes with a 24 inch cable and cigarette lighter plug. WARNING Do not connect to the power source if flammable fumes are present. Explosion or fire may result. Power Source You will need an 11 to 15 volt DC power source capable of supplying enough current to run the test load. [. . . ] Although the inverter is protected in this way, it may still be damaged should the input voltage exceed 16 volts. Input Voltage Cigarette Lighter Plug Your CPI 200 will operate from input voltage ranging from 10 to 15 volts. Optimum performance occurs when the voltage is between 12 and 14 volts. CAUTION NOTE: Make sure you unplug inverter from power source before you leave your vehicle. Automatic Shutdown The unit will automatically go into thermal shutdown if it becomes overheated due to excessive input voltage, poor circulation or high ambient temperature. 5 6 10271_CPI200CH_vB. qx 8/14/07 12:51 PM Page 8 6 TROUBLESHOOTING GUIDE MAINTENANCE & SERVICE Maintaining Your Inverter Possible Causes Solution Problem/ Symptom Low output voltage No output voltage Overload Low input voltage Reduce the load. Check regulation of charging system. No output voltage and "fault" indicator is lit High input voltage Your CPI 200 requires very little maintenance to keep it operating properly. The exterior of the unit should be cleaned periodically with a damp cloth to prevent accumulation of dust and dirt. Keep vents and fans free from dust or debris. · Customer Service Operators are available at 773-889-3087 Monday through Friday, 8:00 a. m. · Automated Technical Assistance is available 24 hours, 7 days a week via e-mail at: productinfo@cobra. com. · On-line answers to frequently asked questions can be found at: www. cobra. com. Cobra®, Nothing Comes Close to a Cobra® and the snake design are registered trademarks of Cobra Electronics Corporation, USA. 7 Service You can receive technical assistance with your unit through one of our customer support services: · Automated Help Desk is available 24 hours a day, 7 days a week at 773-889-3087. No output voltage when load is in excess of 200 watts or 1. 3 amperes Thermal shutdown Allow inverter to cool down Improve ventilation-- make sure ventilation openings in the inverter are not obstructed. Lower ambient temperature. WARNING: This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling. 7 8 10271_CPI200CH_vB. qx 8/14/07 12:51 PM Page 10 7 MAINTENANCE & SERVICE 4. Ship prepaid and insured using a traceable carrier such as United Parcel Service (UPS), Federal Express, or first class mail with delivery confirmation. Ship to: Cobra® Factory Service, Cobra Electronics Corporation, 6500 West Cortland Street, Chicago, IL 60707 USA 6. Please allow 3-4 weeks before contacting us about the status of your service. If your unit is under warranty, it will either be repaired or replaced upon receipt, depending on the model. If your unit is out of warranty, you will receive a letter informing you of the repair or replacement charge. For each piece of equipment you will be powering with your CPI 200, you must determine the battery's capacity (how long the battery can deliver a specific amount of current). For example, automotive batteries usually provide 25 amperes of current. [. . . ] This warranty may be enforced by the first consumer purchaser, provided that the product is utilized within the U. S. A. Cobra® will, without charge, repair or replace, at its option, a defective inverter upon delivery to the Cobra® Factory Service Department, accompanied by proof of the date of first consumer purchase, such as duplicated sales receipt. You must pay initial shipping charges required to ship the product for warranty service, but the return charges will be at Cobra's expense, if the product is repaired or replaced under warranty. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Exclusions: This limited warranty does not apply 1) to any product damaged by accident; 2) in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs; 3) if the serial number has been altered, defaced or removed; 4) if the owner of the product resides outside the U. S. A. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE COBRA CPI 200 CH




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual COBRA CPI 200 CH will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.