User manual COBRA CPI 150 BK

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual COBRA CPI 150 BK. We hope that this COBRA CPI 150 BK user guide will be useful to you.


COBRA CPI 150 BK : Download the complete user guide (411 Ko)

Manual abstract: user guide COBRA CPI 150 BK

Detailed instructions for use are in the User's Guide.

[. . . ] A test load such as a lamp or other small appliance that can be plugged into the AC receptacle on the inverter. QUICK CHECKOUT CAUTION Certain rechargers for small nickel cadmium batteries can be damaged if connected to the CPI 150 BK. Small battery operated appliances that can be plugged directly into an AC receptacle for recharging, including flashlights, razors, and night lights. Certain battery chargers for battery packs used in hand power tools, specifically those that have a WARNING label stating that dangerous voltages are present at the battery terminals. 1 Connecting to the Power Source 2 Your CPI 150 BK comes with a 24 inch cable and detachable cigarette lighter plug that converts to an airplane 12 volt female connector. Do not connect to the power WARNING source if flammable fumes are present. [. . . ] It can deliver 180 watts for about 30 minutes, after which it must cool for about 15 minutes before it can resume operation at 150 watts. (NOTE: the wattage rating applies to resistive loads. ) USB Output: 5 Volt continuous output. The inverter will automatically shut down if the input voltage drops below 10. 0 ± 0. 3 volts. The inverter will restart when the input voltage exceeds 12. 0 ± 0. 3 volts. The inverter will also shut down if the input voltage increases to 15. 5 ± 0. 5 volts. This helps protect the unit from damage due to excessive input voltage. Although the inverter is protected in this way, it may still be damaged should the input voltage exceed 16 volts. Cigarette Lighter Plug power/fault indicator Airplane Plug CAUTION NOTE: Make sure you unplug inverter from power source before you leave your vehicle. Input Voltage Your CPI 150 will operate from input voltage ranging from 10 to 15 volts. Optimum performance occurs when the voltage is between 12 and 14 volts. Automatic Shutdown The unit will automatically go into thermal shutdown if it becomes overheated due to excessive input voltage, poor circulation or high ambient temperature. 6 5 CPI150BK_manual. qx 4/10/06 2:09 PM Page 8 6 TROUBLESHOOTING GUIDE MAINTENANCE & SERVICE Maintaining Your Inverter Possible Causes Solution Problem/ Symptom Low output voltage No output voltage Overload Low input voltage Short circuit or wiring error Reduce the load. Check regulation of charging system. Your CPI 150 requires very little maintenance to keep it operating properly. The exterior of the unit should be cleaned periodically with a damp cloth to prevent accumulation of dust and dirt. Keep vents and fans free from dust or debris. · Customer Service Operators are available at 773-889-3087 Monday through Friday, 8:00 a. m. · Automated Technical Assistance is available 24 hours, 7 days a week via e-mail at: productinfo@cobra. com. · On-line answers to frequently asked questions can be found at: www. cobra. com Cobra®, Nothing Comes Close to a Cobra® and the snake design are registered trademarks of Cobra Electronics Corporation, USA. 7 No output voltage and "fault" indicator is lit High input voltage Service You can receive technical assistance with your unit through one of our customer support services: · Automated Help Desk is available 24 hours a day, 7 days a week at 773-889-3087. No output voltage when load is in excess of 150 watts or 1. 3 amperes Thermal shutdown Allow inverter to cool down Improve ventilation-- make sure ventilation openings in the inverter are not obstructed. Lower ambient temperature. WARNING: This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling. 7 8 CPI150BK_manual. qx 4/10/06 2:09 PM Page 10 7 MAINTENANCE & SERVICE 4. Ship prepaid and insured using a traceable carrier such as United Parcel Service (UPS), Federal Express, or first class mail with delivery confirmation. Ship to: Cobra® Factory Service, Cobra Electronics Corporation, 6500 West Cortland Street, Chicago, IL 60707 USA 6. Please allow 3-4 weeks before contacting us about the status of your service. If your unity is under warranty, it will either be repaired or replaced upon receipt, depending on the model. If your unit is out of warranty, you will receive a letter informing you of the repair or replacement charge. For each piece of equipment you will be powering with your CPI 150, you must determine the battery's capacity (how long the battery can deliver a specific amount of current). [. . . ] The operating features of your CPI 150 BK include: · USB 5V Output · AC receptacle · Automatic thermal protection/shutdown 5V USB Outlet 13V Input Connector · Reverse polarity protection · Low battery shutdown 20 Amp Fuse AC Receptacle Power Cord A2 15 Amp In-Line Fuse cigarette lighter plug Cobra Electronics Corporation warrants that its Cobra® Power Inverter, and the component parts thereof, will be free of defects in material and workmanship for a period of one (1) year from the date of consumer purchase. This warranty may be enforced by the first consumer purchaser, provided that the product is utilized within the U. S. A. Cobra® will, without charge, repair or replace, at its option, a defective inverter upon delivery to the Cobra® Factory Service Department, accompanied by proof of the date of first consumer purchase, such as duplicated sales receipt. You must pay initial shipping charges required to ship the product for warranty service, but the return charges will be at Cobra's expense, if the product is repaired or replaced under warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE COBRA CPI 150 BK




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual COBRA CPI 150 BK will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.