User manual CLIFFORD 50X

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CLIFFORD 50X. We hope that this CLIFFORD 50X user guide will be useful to you.


CLIFFORD 50X : Download the complete user guide (119 Ko)

Manual abstract: user guide CLIFFORD 50X

Detailed instructions for use are in the User's Guide.

[. . . ] World-Class Auto Security TM concept 50x Owner's Manual The Concept 50x is covered by one or more of the following Clifford Electronics U. S. A. patents: 4, 158, 874; 4, 233, 642; 4, 327, 444; 4, 383, 242; 4, 430, 685; 4, 845, 464; 4, 887, 064; 4, 890, 108; 4, 922, 224; 4, 997, 053; 5, 081, 667; 5, 146, 215; 5, 157, 375; 5, 467, 070 and other patents pending. Table of Contents Standard Features of the Concept 50x . False Alarm Prevention and FACT -- False Alarm Control and Test SmartPowerUp II . 19-20 Standard Features of the Concept 50x Lifetime Warranty -- For as long as you own the vehicle, Clifford will repair or replace the control unit and remote controls free of charge (see warranty card for full details). FACT -- False Alarm Control and Test -- One of many patented Clifford innovations, FACT absolutely, positively ends recurring false alarms. [. . . ] Conversely, sensitivity decreases are confirmed with lower and lower toned chirp. There are 32 sensitivity levels for the Proximity Sensor's interior zone; 16 for the less critical warning zone. Repeat steps 6 and 7 until you are satisfied with the sensitivity, then press button 1 to record the new sensitivity setting and exit the sensor test/adjust mode (you'll hear three chirps to confirm exit). You may now either repeat steps 1­4 for the other sensor zone, or press button 1 again to arm the system. Remote controlled override of one or both sensor zones Transmitting channel 10 within 10 seconds of arming the system will override the exterior warning zone of the Proximity Sensor (you'll see 4 parking light flashes to confirm the zone override). Transmitting channel 10 again within the 10 second period will override both zones of the sensor for those times when you must leave a passenger or pet in the vehicle. The sensor zones are automatically restored the next time you arm the system. 12 Built-In Two-Point AutoImmobilizer Thirty seconds after you turn off the ignition, the system's built-in two-point AutoImmobilizer electronically disengages your vehicle's starter motor and electronic fuel pump to ensure against theft of your vehicle. The LED Status Indicator will repeatedly flash to indicate that AutoImmobilization has been activated. Even if a thief were to cut all the wires or even find the Concept 50x control unit and disconnect it, he would still be unable to start the engine. Please be aware that, unlike AutoArming described above, AutoImmobilization occurs regardless of whether you open or close any doors. What's more, disabling the AutoArming feature has no effect on AutoImmobilization. When you remotely disarm your Concept 50x, the AutoImmobilization circuits automatically disengage. You then have 30 seconds to start the engine (or turn the ignition switch to its "ON" position). If more than 30 seconds pass, the immobilizer will automatically reactivate. This will be visually indicated by the LED repeatedly flashing. To disarm the AutoImmobilizer, use the remote control to arm and then disarm the system. Smart AutoTesting Each time you remotely arm the system, it tests all triggers and sensors. If the hood or trunk is open, the system will immediately alert you with 4 chirps and 4 indicator light flashes instead of the usual 2 and 2. If a door is ajar, you will receive the usual 2 chirps and 2 flashes, then, 5 seconds later, 4 chirps and 4 flashes. (The door ajar warning will not work on vehicles with factory-delayed or dimming courtesy lights). If a sensor is malfunctioning, you will receive the usual 2 chirps and 2 flashes, then, 10 seconds later, there will be 4 chirps and 4 flashes. Specific malfunction identification: If you get the 4-chirp/4-flash signal upon arming, perform the following to identify the malfunctioning trigger or sensor: 1. The LED status indicator inside your vehicle will be flashing, pause, then repeat. Count the number of blinks in one cycle between pauses (for your convenience, the blink cycle repeats a total of 5 times) and refer to the chart below: Number of LED blinks between pauses 1 blink 3 blinks 4 blinks* 5 blinks 6 blinks Trigger/sensor indication Proximity Sensor Optional sensor Door trigger* Trunk trigger Hood trigger * If your vehicle has a factory-installed feature that turns off or dims the interior courtesy lights five seconds or more after you exit the vehicle, the system cannot provide this indication. 13 Automatic malfunction bypass In the event of a component malfunction, the system will automatically bypass any faulty point and arm all other triggers and sensors to provide the utmost possible protection until you can have the system serviced by your local Authorized Clifford Dealer. If you accidentally armed with the hood, trunk or a door open, just close the open point and the system will again monitor that point. Multiple-event TotalRecall The system's memory records the identity of the last 8 activated or malfunctioning triggers and sensors, which allows your installer to track down any malfunction. [. . . ] If you wait more than 10 seconds, the system automatically jumps back to the "Feature Select" position. This is the "stand-by" position: ready for entry of a new programming selection. If no action is taken for the next 60 seconds, the system automatically exits program mode, perfect if you program while driving or if you forget to turn off the ignition. Adding new remote controls For other drivers in your family, or if you wish to control Concept 50x systems on your other cars with the same remote control, you can buy additional remote controls from any Clifford Dealer and program them into the system yourself. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CLIFFORD 50X




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CLIFFORD 50X will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.