User manual CITIZEN SR-275

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CITIZEN SR-275. We hope that this CITIZEN SR-275 user guide will be useful to you.


CITIZEN SR-275 : Download the complete user guide (154 Ko)

Manual abstract: user guide CITIZEN SR-275

Detailed instructions for use are in the User's Guide.

[. . . ] SR270ll / SR-275 Scientific Calculator GENERAL GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 TURNING ON OR OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 BATTERY REPLACEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 AUTO POWER-OFF FUNCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Enter [ 2 ] to let this calculator being operated under standard deviation mode. COMP SD REG 1 23 [ 2] SD 0. Using "2nd" keys To execute the functions marked in yellow, please press [ 2nd ] and then the corresponding key. When you press [ 2nd ], the "2nd" indicator shown in the display is to tell you that you will be selecting the second function of the next key you press. If you press [ 2nd ] by mistake, simply press [ 2nd ] again to remove the "2nd" indicator. Cursor Pressing [ ] or [ ] key can move the cursor to the left or the right. Pressing [ 2nd ] [ ] or [ 2nd ] [ ] can scroll the display up or down while there are previous entries hidden the display. You can reuse or edit a previous entry when it is on the entry line. Making corrections during input To delete a character at the cursor, make the character underlined by using [ ] or [ ] to move the cursor, and then press [ DEL ] to delete the character. To replace a character, make the character underlined by using [ ] or [ ] to move the cursor, and then enter a new entry to replace the character. To insert a character, move the cursor to the position of the character where you want to insert, it will be inserted in the front of the character after pressing [ 2nd ] [ INS ] and entering a new character. (Note) : The blinking cursor " " means the calculator is in insert mode On the contrary, the blinking cursor is displayed as "_" and it means the calculator is in overwrite mode. To clear all characters, clear all input character by [ ON/AC ] key. -E4- Replay function · This function stores the latest operation executed. After execution is completed, pressing [ 2nd ] [ ] or [ 2nd ] [ ] key will display the operation from the beginning or the end. · The replay function can keep input digits up to 256 characters for SR-270ll / SR-275. After execution is completed or during entering, you can press either [2nd ] [ ] or [ 2nd ] [ ] to display previous input steps and edit values or commands for subsequent execution. (Note) : The replay function isn't cleared even when [ ON/AC ] is pressed or power is turned off, so contents can be recalled even after [ ON/AC ] is pressed. Error position display function · When a mathematically illegal calculation is performed, error position display function will tell you with the cursor where the error is. You can also clear an error by pressing [ ON/AC ] and then reentered the values and expression from the beginning. See Example 3. Memory calculation Independent memory · Press [ M+ ] to add a result to running memory. (Note) : Besides pressing [ STO ] key to store a value, you can also assign values to memory variable M by [ M+ ] or [M­]. Memory variable · The calculator has nine memory variables for repeated use : A, B, C, D, E, F, M, X, Y. * [ 2nd ] [ Mcl ] [ = ] clears all variables. -E5- Stack This calculator uses memory areas, called "stacks", to temporarily store values (numeric stack) and commands (command stack) according to their precedence during calculations. A stack error (Stk ERROR) occurs whenever you try to perform a calculation that is so complex that the capacity of a stack is exceeded. Order of operations Each calculation is performed in the following order of precedence : 1) Coordinates transformation. 2) Type A functions which are required entering values before pressing the function key, for example, x2, , x !, x ­1. 6) Type B functions which are required pressing the function key before entering, for example, sin, cos, tan, sin ­1, cos ­1, tan ­1, , sinh, cosh, tanh, sinh ­1, cosh ­1, tanh ­1, log, ln, 10X , eX, 3 , (­). 7) Abbreviated multiplication format in front of Type B functions 2 3 , Alog2, etc. [. . . ] Change the default angle settings to the units you want to convert to. D 1 R 2 G 3 The units you can select are D(degrees), R(radians), G(Gradians). functions · SR-270ll / SR-275 provides standard trigonometric functions and inverse trigonometric functions - sin, cos, tan, sin­1, cos­1 and tan­ 1 . (Note) : When using those keys, make sure the calculator is set for the angle unit you want. Hyperbolic / Inverse-Hyp. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CITIZEN SR-275




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CITIZEN SR-275 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.