User manual CITIZEN PPU-700U BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CITIZEN PPU-700U. We hope that this CITIZEN PPU-700U user guide will be useful to you.


CITIZEN PPU-700U BROCHURE: Download the complete user guide (3028 Ko)

Manual abstract: user guide CITIZEN PPU-700UBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] PRINTER PRESENTER UNIT MODEL PPU-700 User's Manual WEEE MARK En Ge Fr Sp It Du Da Por Pol Declaration of Conformity This printer conforms to the following Standards: Low Voltage Directive 73/23/EEC, 93/68/EEC and the EMC Directive 89/336/EEC, 92/31/EEC, 93/68/EEC. LVD : EN60950 EMC : EN55022 EN61000-3-2 EN61000-3-3 EN55024 Class A This declaration is applied only for 230V model. CITIZEN is registered trade mark of CITIZEN WATCH CO. , LTD. , Japan CITIZEN es una marca registrada de CITIZEN WATCH CO. , LTD. , Japón IMPORTANT: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference. CAUTION: Use shielded cable for this equipment. Sicherheitshinweis Die Steckdose zum Anschluß dieses Druckers muß nahe dem Gerät angebracht und leicht zugänglich sein. For Uses in Canada This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus, as set out in the radio interference regulations of the Canadian department of communications. [. . . ] When using a large-diameter paper roll, be sure to provide a shock absorber to prevent shock during rotation of paper roll. 55 ° 15. 5 120 5. 4 PHU-3*** (Paper Feed Unit) Installation Refer to "Appendix-2. PHU-3*** (Paper Feed Unit) Installation". -- 43 -- 74. 5 Ra ng e Pa pe rI ns tio er n Pa th 5. 5 Layout Examples of Control Box Separation of Control Box from Printer allows you to enjoy free layout. PPU-700 Layout Example (1/3) Basic Type Example 1) With board installed separately. PPU-700 Layout Example (2/3) Example 2) With board installed below PPU-700. Example 3) With board installed above PPU-700. PPU-700 Layout Example (3/3) Example 4) With paper holder installed under PPU-700. Example 5) With paper holder installed above PPU-700. -- 44 -- 6. DIP SWITCHES 6. 1 Setting DIP Switches The DIP switch is located on the serial interface board of the printer. (Be sure not to have the screw be lost. ) Slide the interface board to remove it. After setting, remount the interface board and screw it. CAUTION! G Pay attention to the edge of the interface board. Do not use longer size. ) G Turn the printer power off before setting DIP switches. G Do not use the printer with the interface board removed. -- 45 -- 6. 2 DIP Switch Functions DIP Switches Switch No. 1 2 3 4 5 6 7 8 INIT Reset Disabled Function ON OFF DIP switch setting is disabled. DTR/DSR 8-bit No parity Odd parity Factory Setting ON OFF OFF OFF OFF ON ON OFF Setting and selecting DIP switch setting is condition for communication enabled. Communication mode Bit length Parity check Selecting parity Selecting baud rate Xon/Xoff 7-bit With parity Even parity (See Table 1) Table 1 Selecting baud rate Baud Rate (bps) 2, 400 4, 800 9, 600 19, 200 Switch No. MEMORY SWITCHES 7. 1 Setting Memory Switches Memory switch is a generic name for the following. (1) Memory switches MSW1, MSW2, MSW3, MSW4 (2) Customize value (3) Condition for communication through serial interface The memory switch can be selected, changed, or written by the combination of three actions: pressing the FEED switch, pressing and holding the FEED switch, and opening or closing the paper cover. Entering memory switch setting mode Set paper to the printer and keep the printer cover open. With the FEED switch pressed and held, turn the printer power on, and then press the FEED switch twice. Selecting memory switch When the FEED switch is pressed short (within 2 seconds), printing occurs in the order of "MSW1" "MSW2" "MSW3" "MSW4" "Write/ Factory Setting" "MSW1" . . . . . When the memory switch you want to change is reached, press and hold the FEED switch (for more than 2 seconds). Selecting each switch item There are eight setting items for each switch. Press and hold the FEED switch for long (within 2 seconds), the printer goes to the next item and prints the current setting of the item. Repeat pressing and holding till the item you want to change setting is reached. Changing the setting When the item you want to change is reached, press the FEED switch short. When you press the FEED switch long, the set value is accepted and then the printer goes to the next setting item. -- 47 -- 5. Returning to the memory switch select mode When the setting of the desired content is completed, open the paper cover and then close the paper cover. [. . . ] 1 2 3 4 5 6 7 8 Funktion AN Werkseitige Einstellung DIP-Schalter-Einstellung AN ist aktiviert AUS DTR/DSR 8-Bit Keine Parität Ungerade Parität AUS AUS AUS AUS AN AN Reset Deaktiviert AUS Einstellen und Wählen der DIP-Schalter-Einstellung Bedingungen für Kommunikation ist aktiviert Kommunikationsmodus Bitlänge Paritätsprüfung Auswählen der Parität Auswählen der Baudrate INIT Xon/Xoff 7-Bit Mit Parität Gerade Parität (Siehe Tabelle 1) Tabelle 1 Auswählen der Baudrate Baudrate (Bit/s) 2, 400 4, 800 9, 600 19, 200 Switch-Nr. SPEICHERSCHALTER 7. 1 Einstellen der Speicher-Switches Speicher-Switch ist ein generischer Name für folgendes. (1) Speicher-Switch MSW1, MSW2, MSW3, MSW4 (2) Anpassungswert (3) Bedingung für Kommunikation über serielle Schnittstelle Um Speicher-Switches auszuwählen, anzupassen oder zu schreiben, führen Sie folgende drei Schritte aus: Drücken Sie die Vorschubtaste (FEED) und halten Sie sie gedrückt, und öffnen oder schließen Sie die Papierabdeckung. Aktivieren des Einstellmodus für Speicher-Switches Führen Sie Papier in den Drucker ein und lassen Sie die Papierabdeckung geöffnet. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CITIZEN PPU-700U




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CITIZEN PPU-700U will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.